357 research outputs found
The development, application and analysis of an enhanced recovery programme for major oesophagogastric resection
Background: Enhanced recovery programmes improve outcomes in surgery, but their implementation after upper gastrointestinal resection has been limited. The aim of this study was to compare short-term outcomes for patients undergoing oesophagogastric surgery in an enhanced recovery programme (EROS). Methods: EROS was developed after a multidisciplinary meeting by multiple rounds of revision. EROS was applied to all patients undergoing major upper GI resection at a university teaching hospital in the UK from 20/9/13, with data reviewed at 18/09/15. EROS was assessed to identify predictors for compliance. Results: One hundred six patients underwent major upper GI resection including 81 oesophagectomies, 24 gastrectomies and 1 colonic interposition graft. Major complications (ClavienDindoâ„3) occurred in 12 patients with 1 in-hospital death. Thirty-five patients (44%) were discharged on target day 8 of the EROS programme. Age and complications were independently associated with missing this discharge target. Conclusion: Enhanced recovery is feasible and safe after major upper gastrointestinal surgery.<br/
Measurement of 222Rn dissolved in water at the Sudbury Neutrino Observatory
The technique used at the Sudbury Neutrino Observatory (SNO) to measure the
concentration of 222Rn in water is described. Water from the SNO detector is
passed through a vacuum degasser (in the light water system) or a membrane
contact degasser (in the heavy water system) where dissolved gases, including
radon, are liberated. The degasser is connected to a vacuum system which
collects the radon on a cold trap and removes most other gases, such as water
vapor and nitrogen. After roughly 0.5 tonnes of H2O or 6 tonnes of D2O have
been sampled, the accumulated radon is transferred to a Lucas cell. The cell is
mounted on a photomultiplier tube which detects the alpha particles from the
decay of 222Rn and its daughters. The overall degassing and concentration
efficiency is about 38% and the single-alpha counting efficiency is
approximately 75%. The sensitivity of the radon assay system for D2O is
equivalent to ~3 E(-15) g U/g water. The radon concentration in both the H2O
and D2O is sufficiently low that the rate of background events from U-chain
elements is a small fraction of the interaction rate of solar neutrinos by the
neutral current reaction.Comment: 14 pages, 6 figures; v2 has very minor change
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry
The emerging structure of the Extended Evolutionary Synthesis: where does Evo-Devo fit in?
The Extended Evolutionary Synthesis (EES) debate is gaining ground in contemporary evolutionary biology. In parallel, a number of philosophical standpoints have emerged in an attempt to clarify what exactly is represented by the EES. For Massimo Pigliucci, we are in the wake of the newest instantiation of a persisting Kuhnian paradigm; in contrast, Telmo Pievani has contended that the transition to an EES could be best represented as a progressive reformation of a prior Lakatosian scientific research program, with the extension of its Neo-Darwinian core and the addition of a brand-new protective belt of assumptions and auxiliary hypotheses. Here, we argue that those philosophical vantage points are not the only ways to interpret what current proposals to âextendâ the Modern Synthesis-derived âstandard evolutionary theoryâ (SET) entail in terms of theoretical change in evolutionary biology. We specifically propose the image of the emergent EES as a vast network of models and interweaved representations that, instantiated in diverse practices, are connected and related in multiple ways. Under that assumption, the EES could be articulated around a paraconsistent network of evolutionary theories (including some elements of the SET), as well as models, practices and representation systems of contemporary evolutionary biology, with edges and nodes that change their position and centrality as a consequence of the co-construction and stabilization of facts and historical discussions revolving around the epistemic goals of this area of the life sciences. We then critically examine the purported structure of the EESâpublished by Laland and collaborators in 2015âin light of our own network-based proposal. Finally, we consider which epistemic units of Evo-Devo are present or still missing from the EES, in preparation for further analyses of the topic of explanatory integration in this conceptual framework
miRNA-Seq identifies a serum miRNA panel, which combined with APRI can detect and monitor liver disease in paediatric Cystic Fibrosis
Cystic fibrosis (CF)-associated liver disease (CFLD) is a hepatobiliary complication of CF. Current diagnostic modalities rely on non-specific assessments, while liver biopsy is the gold standard to assess severity of fibrosis. MicroRNAs (miRNAs) regulate liver disease pathogenesis and are proposed as diagnostic biomarkers. We investigated the combined use of serum miRNAs and aspartate aminotransferase to platelet ratio (APRI) to diagnose and assess CFLD severity. This was a cross-sectional cohort study of the circulatory miRNA signature of 124 children grouped by clinical, biochemical and imaging assessments as follows: CFLD (n=44), CF patients with no evidence of liver disease (CFnoLD, n=40) and healthy controls (n=40). Serum miRNAs were analysed using miRNA-sequencing. Selected differentially expressed serum miRNA candidates were further validated by qRT-PCR and statistical analysis performed to evaluate utility to predict CFLD and fibrosis severity validated by liver biopsy, alone or in combination with APRI. Serum miR-122-5p, miR-365a-3p and miR-34a-5p levels were elevated in CFLD compared to CFnoLD, while miR-142-3p and let-7g-5p were downregulated in CFLD compared to CFnoLD. Logistic regression analysis combining miR-365a-3p, miR-142-3p and let-7g-5p with APRI showed 21 times greater odds of accurately predicting liver disease in CF with an AUROC=0.91 (sensitivity=83%, specificity=92%;
In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum
efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and
is of significant interest for future dark matter and neutrino experiments
where high signal yields are needed.
We report on the methods developed for in-situ characterization and
monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of
typical measured single-photoelectron charge distributions, correlated noise
(afterpulsing), dark noise, double, and late pulsing characteristics. The
characterization is performed during the detector commissioning phase using
laser light injected through a light diffusing sphere and during normal
detector operation using LED light injected through optical fibres
Measurement of the Total Active 8B Solar Neutrino Flux at the Sudbury Neutrino Observatory with Enhanced Neutral Current Sensitivity
The Sudbury Neutrino Observatory (SNO) has precisely determined the total
active (nu_x) 8B solar neutrino flux without assumptions about the energy
dependence of the nu_e survival probability. The measurements were made with
dissolved NaCl in the heavy water to enhance the sensitivity and signature for
neutral-current interactions. The flux is found to be 5.21 +/- 0.27 (stat) +/-
0.38 (syst) x10^6 cm^{-2}s^{-1}, in agreement with previous measurements and
standard solar models. A global analysis of these and other solar and reactor
neutrino results yields Delta m^{2} = 7.1^{+1.2}_{-0.6}x10^{-5} ev^2 and theta
= 32.5^{+2.4}_{-2.3} degrees. Maximal mixing is rejected at the equivalent of
5.4 standard deviations.Comment: Submitted to Phys. Rev. Let
Electron Antineutrino Search at the Sudbury Neutrino Observatory
Upper limits on the \nuebar flux at the Sudbury Neutrino Observatory have
been set based on the \nuebar charged-current reaction on deuterium. The
reaction produces a positron and two neutrons in coincidence. This distinctive
signature allows a search with very low background for \nuebar's from the Sun
and other potential sources. Both differential and integral limits on the
\nuebar flux have been placed in the energy range from 4 -- 14.8 MeV. For an
energy-independent \nu_e --> \nuebar conversion mechanism, the integral limit
on the flux of solar \nuebar's in the energy range from 4 -- 14.8 MeV is found
to be \Phi_\nuebar <= 3.4 x 10^4 cm^{-2} s^{-1} (90% C.L.), which corresponds
to 0.81% of the standard solar model 8B \nu_e flux of 5.05 x 10^6 cm^{-2}
s^{-1}, and is consistent with the more sensitive limit from KamLAND in the 8.3
-- 14.8 MeV range of 3.7 x 10^2 cm^{-2} s^{-1} (90% C.L.). In the energy range
from 4 -- 8 MeV, a search for \nuebar's is conducted using coincidences in
which only the two neutrons are detected. Assuming a \nuebar spectrum for the
neutron induced fission of naturally occurring elements, a flux limit of
Phi_\nuebar <= 2.0 x 10^6 cm^{-2} s^{-1}(90% C.L.) is obtained.Comment: submitted to Phys. Rev.
- âŠ