31 research outputs found

    Assessment of fetal development by HRV and chaotic global techniques

    Get PDF
    Introduction: Fetal heart rate and its variability during the course of gestation have been extensively researched. The overall reduction in heart rate and increase in fetal HRV is associated with fetal growth and the increase in neural integration. The increased complexity of the demands on the cardiovascular system leads to more variation in the temporal course of the heart rate which has been shown to be refl ected in measures of complexity. The aim of this work was to investigate novel complexity measures with respect to their ability to quantify changes over gestational age in individual fetuses consistently and in a stable manner. Methods: We examined 215 fetal magnetocardiograms (FMCG), each of 5 min duration, in 11 fetuses during the second and third trimesters (at least 10 data sets per fetus). From the FMCG we determined the  etal RR beat durations. For each 5 min time-series of RR intervals we then calculated Shannon entropy, high spectral entropy, high spectral Detrended Fluctuation Analysis, spec ral Multi-Taper Method as well as the standard deviation and two commonly used complexity measures: Approximate Entropy and Sample Entropy. For each subject and HRV measure, we performed regression analysis with respect to ges tational age. The coeffi cient of determination R2 was used to es timate ‘goodness-of-fi t’, the slope of the regression indicated the strength of the individual dependency on gestational age. Results: We found that the new complexity measures do not outperform ApEn. Conclusion: This study has now rejected the hypothesis that the spectral complexity measures outperform those applied previously

    Is there evidence of fetal-maternal heart rate synchronization?

    Get PDF
    BACKGROUND: The prenatal condition offers a unique possibility of examining physiological interaction between individuals. Goal of this work was to look for evidence of coordination between fetal and maternal cardiac systems. METHODS: 177 magnetocardiograms were recorded in 62 pregnancies (16(th)–42(nd )week of gestation). Fetal and maternal RR interval time series were constructed and the phases, i.e. the timing of the R peaks of one time series in relation to each RR interval of the other were determined. The distributions of these phases were examined and synchrograms were constructed for real and surrogate pairs of fetal and maternal data sets. Synchronization epochs were determined for defined n:m coupling ratios. RESULTS: Differences between real and surrogate data could not be found with respect to number of synchronization epochs found (712 vs. 741), gestational age, subject, recording or n:m combination. There was however a preference for the occurrence of synchronization epochs in specific phases in real data not apparent in the surrogate for some n:m combinations. CONCLUSION: The results suggest that occasional coupling between fetal and maternal cardiac systems does occur

    A novel cross-sector telemedical approach to detect arrhythmia in primary care patients with palpitations using a patient-activated event recorder

    Get PDF
    Background: Patient-activated event recorders (ER) can facilitate diagnosis in unclear palpi­tations, however impact of ER screening on further treatment in clinical routine is unknown. We investigated the feasibility and clinical value of a network-based telemetric monitoring using a patient activated ER. Methods: The network consisted of 12 general practitioners (GP) and a department of car­diology (DC). GP-patients sent electrocardiograms (ECGs) twice daily and in case of palpitations. ECGs were transferred by email to GP and DC and analyzed independently by both. The therapeutic strategy was discussed between GP and DC. The monitoring period ended after 4 weeks or in case of detected arrhythmia. Results: A group of 184 consecutive patients were retrospectively analyzed. Mean age was 57.5 ± 14.4 years (range 17–82), 104 (56.5%) were female. Significant arrhythmia occurred in 71 (38.5%) patients: Recurrence of known paroxysmal atrial fibrillation (AF; n = 27, 14.7%), de novo AF (n = 19, 10.3%), premature complexes/bigeminus (n = 13, 7.1%), sinus tachycar­dia (n = 7, 3.8%), atrioventricular nodal reentrant tachycardia (n = 3, 1.6%), and ventricular tachycardia (n = 2, 1.1%). A therapeutic consequence resulted in 63 (88.7%) patients with de­tected arrhythmia: new oral anticoagulation (n = 29, 40.8%), new antiarrhythmic medication (n = 27, 38.0%), behavioral intervention (n = 19, 26.8%), electrophysiology-study/catheter ablation (n = 4, 5.6%), cardioversion (n = 2, 2.8%), implantable cardioverter-defibrillator- -implantation (n = 1, 1.4%), and left atrial appendage occluder (n = 1, 1.4%). Conclusions: The investigated cross-sector telemetric network is a feasible approach to detect arrhythmia in patients with palpitations and may have high impact on further treatment, notably in those at risk for stroke due to AF

    Finite volume analysis of temperature effects induced by active MRI implants with cylindrical symmetry: 1. Properly working devices

    Get PDF
    BACKGROUND: Active Magnetic Resonance Imaging implants are constructed as resonators tuned to the Larmor frequency of a magnetic resonance system with a specific field strength. The resonating circuit may be embedded into or added to the normal metallic implant structure. The resonators build inductively coupled wireless transmit and receive coils and can amplify the signal, normally decreased by eddy currents, inside metallic structures without affecting the rest of the spin ensemble. During magnetic resonance imaging the resonators generate heat, which is additional to the usual one described by the specific absorption rate. This induces temperature increases of the tissue around the circuit paths and inside the lumen of an active implant and may negatively influence patient safety. METHODS: This investigation provides an overview of the supplementary power absorbed by active implants with a cylindrical geometry, corresponding to vessel implants such as stents, stent grafts or vena cava filters. The knowledge of the overall absorbed power is used in a finite volume analysis to estimate temperature maps around different implant structures inside homogeneous tissue under worst-case assumptions. The "worst-case scenario" assumes thermal heat conduction without blood perfusion inside the tissue around the implant and mostly without any cooling due to blood flow inside vessels. RESULTS: The additional power loss of a resonator is proportional to the volume and the quality factor, as well as the field strength of the MRI system and the specific absorption rate of the applied sequence. For properly working devices the finite volume analysis showed only tolerable heating during MRI investigations in most cases. Only resonators transforming a few hundred mW into heat may reach temperature increases over 5 K. This requires resonators with volumes of several ten cubic centimeters, short inductor circuit paths with only a few 10 cm and a quality factor above ten. Using MR sequences, for which the MRI system manufacturer declares the highest specific absorption rate of 4 W/kg, vascular implants with a realistic construction, size and quality factor do not show temperature increases over a critical value of 5 K. CONCLUSION: The results show dangerous heating for the assumed "worst-case scenario" only for constructions not acceptable for vascular implants. Realistic devices are safe with respect to temperature increases. However, this investigation discusses only properly working devices. Ruptures or partial ruptures of the wires carrying the electric current of the resonance circuits or other defects can set up a power source inside an extremely small volume. The temperature maps around such possible "hot spots" should be analyzed in an additional investigation

    Aerobic Exercise during Pregnancy and Presence of Fetal-Maternal Heart Rate Synchronization

    Get PDF
    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization.In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance.In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data.The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates

    Dependency of magnetocardiographically determined fetal cardiac time intervals on gestational age, gender and postnatal biometrics in healthy pregnancies

    Get PDF
    BACKGROUND: Magnetocardiography enables the precise determination of fetal cardiac time intervals (CTI) as early as the second trimester of pregnancy. It has been shown that fetal CTI change in course of gestation. The aim of this work was to investigate the dependency of fetal CTI on gestational age, gender and postnatal biometric data in a substantial sample of subjects during normal pregnancy. METHODS: A total of 230 fetal magnetocardiograms were obtained in 47 healthy fetuses between the 15(th )and 42(nd )week of gestation. In each recording, after subtraction of the maternal cardiac artifact and the identification of fetal beats, fetal PQRST courses were signal averaged. On the basis of therein detected wave onsets and ends, the following CTI were determined: P wave, PR interval, PQ interval, QRS complex, ST segment, T wave, QT and QTc interval. Using regression analysis, the dependency of the CTI were examined with respect to gestational age, gender and postnatal biometric data. RESULTS: Atrioventricular conduction and ventricular depolarization times could be determined dependably whereas the T wave was often difficult to detect. Linear and nonlinear regression analysis established strong dependency on age for the P wave and QRS complex (r(2 )= 0.67, p < 0.001 and r(2 )= 0.66, p < 0.001) as well as an identifiable trend for the PR and PQ intervals (r(2 )= 0.21, p < 0.001 and r(2 )= 0.13, p < 0.001). Gender differences were found only for the QRS complex from the 31(st )week onward (p < 0.05). The influence on the P wave or QRS complex of biometric data, collected in a subgroup in whom recordings were available within 1 week of birth, did not display statistical significance. CONCLUSION: We conclude that 1) from approximately the 18(th )week to term, fetal CTI which quantify depolarization times can be reliably determined using magnetocardiography, 2) the P wave and QRS complex duration show a high dependency on age which to a large part reflects fetal growth and 3) fetal gender plays a role in QRS complex duration in the third trimester. Fetal development is thus in part reflected in the CTI and may be useful in the identification of intrauterine growth retardation

    Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots

    No full text
    Abstract Background Active magnetic resonance imaging implants, for example stents, stent grafts or vena cava filters, are constructed as wireless inductively coupled transmit and receive coils. They are built as a resonator tuned to the Larmor frequency of a magnetic resonance system. The resonator can be added to or incorporated within the implant. This technology can counteract the shielding caused by eddy currents inside the metallic implant structure. This may allow getting diagnostic information of the implant lumen (in stent stenosis or thrombosis for example). The electro magnetic rf-pulses during magnetic resonance imaging induce a current in the circuit path of the resonator. A by material fatigue provoked partial rupture of the circuit path or a broken wire with touching surfaces can set up a relatively high resistance on a very short distance, which may behave as a point-like power source, a hot spot, inside the body part the resonator is implanted to. This local power loss inside a small volume can reach ¼ of the total power loss of the intact resonating circuit, which itself is proportional to the product of the resonator volume and the quality factor and depends as well from the orientation of the resonator with respect to the main magnetic field and the imaging sequence the resonator is exposed to. Methods First an analytical solution of a hot spot for thermal equilibrium is described. This analytical solution with a definite hot spot power loss represents the worst case scenario for thermal equilibrium inside a homogeneous medium without cooling effects. Starting with this worst case assumptions additional conditions are considered in a numerical simulation, which are more realistic and may make the results less critical. The analytical solution as well as the numerical simulations use the experimental experience of the maximum hot spot power loss of implanted resonators with a definite volume during magnetic resonance imaging investigations. The finite volume analysis calculates the time developing temperature maps for the model of a broken linear metallic wire embedded in tissue. Half of the total hot spot power loss is assumed to diffuse into both wire parts at the location of a defect. The energy is distributed from there by heat conduction. Additionally the effect of blood perfusion and blood flow is respected in some simulations because the simultaneous appearance of all worst case conditions, especially the absence of blood perfusion and blood flow near the hot spot, is very unlikely for vessel implants. Results The analytical solution as worst case scenario as well as the finite volume analysis for near worst case situations show not negligible volumes with critical temperature increases for part of the modeled hot spot situations. MR investigations with a high rf-pulse density lasting below a minute can establish volumes of several cubic millimeters with temperature increases high enough to start cell destruction. Longer exposure times can involve volumes larger than 100 mm3. Even temperature increases in the range of thermal ablation are reached for substantial volumes. MR sequence exposure time and hot spot power loss are the primary factors influencing the volume with critical temperature increases. Wire radius, wire material as well as the physiological parameters blood perfusion and blood flow inside larger vessels reduce the volume with critical temperature increases, but do not exclude a volume with critical tissue heating for resonators with a large product of resonator volume and quality factor. Conclusion The worst case scenario assumes thermal equilibrium for a hot spot embedded in homogeneous tissue without any cooling due to blood perfusion or flow. The finite volume analysis can calculate the results for near and not close to worst case conditions. For both cases a substantial volume can reach a critical temperature increase in a short time. The analytical solution, as absolute worst case, points out that resonators with a small product of inductance volume and quality factor (Q Vind 3) are definitely save. Stents for coronary vessels or resonators used as tracking devices for interventional procedures therefore have no risk of high temperature increases. The finite volume analysis shows for sure that also conditions not close to the worst case reach physiologically critical temperature increases for implants with a large product of inductance volume and quality factor (Q Vind > 10 cm3). Such resonators exclude patients from exactly the MRI investigation these devices are made for.</p
    corecore