6 research outputs found

    Surgical aortic valve replacement and patient-prosthesis mismatch a meta-analysis of 108 182 patients

    Get PDF
    OBJECTIVES: This study sought to evaluate the impact of patient–prosthesis mismatch (PPM) on the risk of perioperative, early-, mid- and long-term mortality rates after surgical aortic valve replacement. METHODS: Databases were searched for studies published until March 2018. The main outcomes of interest were perioperative mortality, 1-year mortality, 5-year mortality and 10-year mortality. RESULTS: The search yielded 3761 studies for inclusion. Of these, 70 articles were analysed, and their data were extracted. The total num- ber of patients included was 108 182 who underwent surgical aortic valve replacement. The incidence of PPM after surgical aortic valve re- placement was 53.7% (58 116 with PPM and 50 066 without PPM). Perioperative mortality [odds ratio (OR) 1.491, 95% confidence interval (CI) 1.302–1.707; P < 0.001], 1-year mortality (OR 1.465, 95% CI 1.277–1.681; P < 0.001), 5-year mortality (OR 1.358, 95% CI 1.218–1.515; P < 0.001) and 10-year mortality (OR 1.534, 95% CI 1.290–1.825; P < 0.001) were increased in patients with PPM. Both severe PPM and moderate PPM were associated with increased risk of perioperative mortality, 1-year mortality, 5-year mortality and 10-year mortality when analysed together and separately, although we observed a higher risk in the group with severe PPM. CONCLUSIONS: Moderate/severe PPM increases perioperative, early-, mid- and long-term mortality rates proportionally to its severity. The findings of this study support the implementation of surgical strategies to prevent PPM in order to decrease mortality rates

    Prosthesis-patient mismatch negatively affects outcomes after mitral valve replacement : meta-analysis of 10,239 patients

    No full text
    Objective: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and long- term mortality after mitral valve replacement. Methods: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-year mortality and echocardiographic parameters. Results: The research yielded 2,985 studies for inclusion. Of these, 16 articles were analyzed, and their data extracted. The total number of patients included was 10,239, who underwent mitral valve replacement. The incidence of prosthesis-patient mismatch after mitral valve replacement was 53.7% (5,499 with prosthesis- patient mismatch and 4,740 without prosthesis-patient mismatch). Perioperative (OR 1.519; 95%CI 1.194–1.931, P<0.001) and 10-year (OR 1.515; 95%CI 1.280–1.795, P<0.001) mortality was increased in patients with prosthesis-patient mismatch. Patients with prosthesis-patient mismatch after mitral valve replacement had higher systolic pulmonary artery pressure and transprosthethic gradient and lower indexed effective orifice area and left ventricle ejection fraction. Conclusion: Prosthesis-patient mismatch increases perioperative and long-term mortality. Prosthesis-patient mismatch is also associated with pulmonary hypertension and depressed left ventricle systolic function. The findings of this study support the implementation of surgical strategies to prevent prosthesis- patient mismatch in order to decrease mortality rates

    Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients

    No full text
    Abstract Objective: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and long-term mortality after mitral valve replacement. Methods: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-year mortality and echocardiographic parameters. Results: The research yielded 2,985 studies for inclusion. Of these, 16 articles were analyzed, and their data extracted. The total number of patients included was 10,239, who underwent mitral valve replacement. The incidence of prosthesis-patient mismatch after mitral valve replacement was 53.7% (5,499 with prosthesis-patient mismatch and 4,740 without prosthesis-patient mismatch). Perioperative (OR 1.519; 95%CI 1.194-1.931, P<0.001) and 10-year (OR 1.515; 95%CI 1.280-1.795, P<0.001) mortality was increased in patients with prosthesis-patient mismatch. Patients with prosthesis-patient mismatch after mitral valve replacement had higher systolic pulmonary artery pressure and transprosthethic gradient and lower indexed effective orifice area and left ventricle ejection fraction. Conclusion: Prosthesis-patient mismatch increases perioperative and long-term mortality. Prosthesis-patient mismatch is also associated with pulmonary hypertension and depressed left ventricle systolic function. The findings of this study support the implementation of surgical strategies to prevent prosthesis-patient mismatch in order to decrease mortality rates

    Current Practice of State-of-the-Art Coronary Revascularization in Patients with Heart Failure

    No full text
    Abstract The best treatment for patients with ischemic heart failure (HF) is still on debate. There is growing evidence that coronary artery bypass graft (CABG) benefits these patients. The current recommendations for revascularization in this context are that CABG is reasonable when it comes to decreasing morbidity and mortality rates for patients with severe left ventricular dysfunction (ejection fraction <35%), and significant coronary artery disease (CAD) and should be considered in patients with operable coronary anatomy, regardless whether or not there is a viable myocardium (class IIb). Percutaneous coronary intervention (PCI) does not have enough data to allow the panels to reach a conclusion. The Korean Acute Heart Failure registry (KorAHF) had its data released recently, showing that patients with acute HF who underwent CABG had lower death rates, more complete revascularization and less adverse outcomes compared with patients treated with PCI. Recent ESC/EACTS guidelines on myocardial revascularization clearly recommended CABG as the first choice of revascularization strategy in patients with multivessel disease and acceptable surgical risk to improve prognosis in this scenario of left ventricular dysfunction. However, a high peri-procedural risk must be compared with the benefit of late mortality, and pros and cons of each strategy (either PCI or CABG) must be weighed in the decision-making process. Spurred on by the publication of the above-mentioned article and the release of new guidelines, we went on to write an overview of the current practice of state-of-the-art coronary revascularization options in patients with HF

    Impact of surgical aortic root enlargement on the outcomes of aortic valve replacement : a meta-analysis of 13 174 patients

    No full text
    OBJECTIVES: This study sought to evaluate the impact of surgical aortic root enlargement (ARE) on the perioperative outcomes of aortic valve replacement (AVR). METHODS: Databases were searched for studies published until April 2018 to carry out a systematic review followed by meta-analysis of results. RESULTS: The search yielded 1468 studies for inclusion. Of these, 10 articles were analysed and their data extracted. A total of 13 174 patients (AVR with ARE: 2819 patients; AVR without ARE: 10 355 patients) were included from studies published from 2002 to 2018. The total rate of ARE was 21.4%, varying in the studies from 5.7% to 26.3%. The overall odds ratio (OR) [95% confidence interval (CI)] for periop- erative mortality showed a statistically significant difference between the groups (among 10 studies), with a higher risk in the ‘AVR with ARE’ group (OR 1.506, 95% CI 1.209–1.875; P < 0.001), but not when adjusted for isolated AVR + ARE without any concomitant procedures such as mitral valve surgery, coronary artery bypass surgery, etc. (OR 1.625, 95% CI 0.968–2.726; P = 0.066—among 6 studies). The ‘AVR with ARE’ group showed an overall lower risk of significant patient–prosthesis mismatch among 9 studies (OR 0.472, 95% CI 0.295–0.756; P = 0.002) and a higher overall difference in means of indexed effective orifice area among 10 studies (random-effect model: 0.06 cm2/m2, 95% CI 0.029–0.103; P < 0.001). CONCLUSIONS: Surgical ARE seems to be associated with increased perioperative mortality but with lower risk of patient–prosthesis mismatch
    corecore