90 research outputs found

    An orifice shape-based reduced order model of patient-specific mitral valve regurgitation

    Get PDF
    Mitral valve regurgitation (MR) is one of the most prevalent valvular heart diseases. Its quantitative assessment is challenging but crucial for treatment decisions. Using computational fluid dynamics (CFD), we developed a reduced order model (ROM) describing the relationship between MR flow rates, transvalvular pressure differences, and the size and shape of the regurgitant valve orifice. Due to its low computational cost, this ROM could easily be implemented into clinical workflows to support the assessment of MR. We reconstructed mitral valves of 43 patients from 3D transesophageal echocardiographic images and estimated the 3D anatomic regurgitant orifice areas using a shrink-wrap algorithm. The orifice shapes were quantified with three dimensionless shape parameters. Steady-state CFD simulations in the reconstructed mitral valves were performed to analyse the relationship between the regurgitant orifice geometry and the regurgitant hemodynamics. Based on the results, three ROMs with increasing complexity were defined, all of which revealed very good agreement with CFD results with a mean bias below 3% for the MR flow rate. Classifying orifices into two shape groups and assigning group-specific flow coefficients in the ROM reduced the limit of agreement predicting regurgitant volumes from 9.0 ml to 5.7 ml at a mean regurgitant volume of 57 ml

    Hemodynamic changes during physiological and pharmacological stress testing in healthy subjects, aortic stenosis and aortic coarctation patients: a systematic review and meta-analysis

    Get PDF
    Introduction: Exercise testing has become a diagnostic standard in the evaluation and management of heart disease. While different methods of exercise and pharmacological stress testing exist, only little is known about their comparability. We aimed to assess hemodynamic changes during dynamic exercise, isometric exercise, and dobutamine stress testing at different stress intensities in healthy subjects and patients with aortic stenosis (AS) and aortic coarctation (CoA). Methods: A systematic literature search (PROSPERO 2017:CRD42017078608) in MEDLINE of interventional trials was conducted to identify eligible studies providing evidence of changes in hemodynamic parameters under different stress conditions acquired by MRI or echocardiography. A random effects model was used to estimate pooled mean changes in hemodynamics. Results: One hundred and twenty-eight study arms with a total of 3,139 stress-examinations were included. In healthy subjects/(where available) in AS, pooled mean changes (95% CIs) during light dynamic stress were 31.78 (27.82–35.74) bpm in heart rate (HR) and 6.59 (2.58–10.61) ml in stroke volume (SV). Changes during light pharmacological stress were 13.71 (7.87–19.56)/14.0 (9.82–18.18) bpm in HR, and 5.47 (0.3–10.63)/8.0 (3.82–12.18) ml in SV. Changes during light isometric stress were 18.44 (10.74–26.14)/5.0 (−1.17–11.17) bpm in HR and −4.17 (−14.37–6.03)/−4.0 (−16.43–8.43) ml in SV. Changes during moderate dynamic stress were 49.57 (40.03–59.1)/46.45 (42.63–50.27) bpm in HR and 11.64 (5.87–17.42) ml in SV. During moderate pharmacological stress, changes in HR were 42.83 (36.94–48.72)/18.66 (2.38–34.93) bpm and in SV 6.29 (−2.0–14.58)/13.11 (7.99–18.23) ml. During high intensity dynamic stress changes in HR were 89.31 (81.46–97.17)/55.32 (47.31–63.33) bpm and in SV 21.31 (13.42–29.21)/−0.96 (−5.27–3.35) ml. During high pharmacological stress, changes in HR were 53.58 (36.53–70.64)/42.52 (32.77–52.28) bpm, and in SV 0.98 (−9.32–11.27)/14.06 (−1.62–29.74) ml. HR increase and age were inversely correlated at high stress intensities. In CoA, evidence was limited to single studies. Conclusion: This systematic review and meta-analysis presents pooled hemodynamic changes under light, moderate and high intensity exercise and pharmacological stress, while considering the potential influence of age. Despite limited availability of comparative studies, the reference values presented in this review allow estimation of the expected individual range of a circulatory response in healthy individuals and patients with AS and may contribute to future study planning and patient-specific models even when stress testing is contraindicated

    CARDIOKIN1: computational assessment of myocardial metabolic capability in healthy controls and patients with valve diseases

    Get PDF
    BACKGROUND: Many heart diseases can develop a reduced pumping capacity of the heart muscle. A mismatch between ATP demand and ATP production of cardiomyocytes is one of the possible causes. Assessment of the relation between the myocardial ATP production (MV(ATP)) and cardiac workload is important for better understanding disease development and choice of nutritional or pharmacological treatment strategies. As there is currently no method for the measurement of MV(ATP) in vivo, the use of physiology-based metabolic models in conjunction with protein abundance data is an attractive approach. METHODS: We developed a comprehensive kinetic model of the cardiac energy metabolism (CARDIOKIN1), which recapitulates numerous experimental findings on cardiac metabolism obtained with isolated cardiomyocytes, perfused animal hearts and in vivo studies with humans. We used the model to assess the energy status of the left ventricle (LV) of healthy subjects and patients with aortic stenosis (AS) and mitral valve insufficiency (MI). Maximal enzyme activities were individually scaled by means of protein abundances in LV tissue samples. The energy status of the LV was quantified by the ATP consumption at rest (MV(ATP)(rest)), at maximal workload (MV(ATP)(max)), and by the myocardial ATP production reserve (MAPR) representing the span between MV(ATP)(rest) and MV(ATP)(max). RESULTS: Compared with controls, in both groups of patients, MV(ATP)(rest) was increased and MV(ATP)(max) was decreased resulting in a decreased MAPR, although all patients had preserved ejection fraction. Notably, the variance of the energetic status was high ranging from decreased to normal values. In both patient groups, the energetic status was tightly associated with mechanic energy demand. Moreover, a decrease of MV(ATP)(max) was associated with a decrease of the cardiac output indicating that cardiac functionality and energetic performance of the ventricle are closely coupled. CONCLUSIONS: Our analysis suggests that the ATP producing capacity of the LV of patients with valvular dysfunction is generally diminished and correlates positively with mechanic energy demand and cardiac output. However, large differences exist in the energetic state of the myocardium even in patients with similar clinical or image-based markers of hypertrophy and pump function

    Computational model of blood flow in the aorto-coronary bypass graft

    Get PDF
    BACKGROUND: Coronary artery bypass grafting surgery is an effective treatment modality for patients with severe coronary artery disease. The conduits used during the surgery include both the arterial and venous conduits. Long- term graft patency rate for the internal mammary arterial graft is superior, but the same is not true for the saphenous vein grafts. At 10 years, more than 50% of the vein grafts would have occluded and many of them are diseased. Why do the saphenous vein grafts fail the test of time? Many causes have been proposed for saphenous graft failure. Some are non-modifiable and the rest are modifiable. Non-modifiable causes include different histological structure of the vein compared to artery, size disparity between coronary artery and saphenous vein. However, researches are more interested in the modifiable causes, such as graft flow dynamics and wall shear stress distribution at the anastomotic sites. Formation of intimal hyperplasia at the anastomotic junction has been implicated as the root cause of long- term graft failure. Many researchers have analyzed the complex flow patterns in the distal sapheno-coronary anastomotic region, using various simulated model in an attempt to explain the site of preferential intimal hyperplasia based on the flow disturbances and differential wall stress distribution. In this paper, the geometrical bypass models (aorto-left coronary bypass graft model and aorto-right coronary bypass graft model) are based on real-life situations. In our models, the dimensions of the aorta, saphenous vein and the coronary artery simulate the actual dimensions at surgery. Both the proximal and distal anastomoses are considered at the same time, and we also take into the consideration the cross-sectional shape change of the venous conduit from circular to elliptical. Contrary to previous works, we have carried out computational fluid dynamics (CFD) study in the entire aorta-graft-perfused artery domain. The results reported here focus on (i) the complex flow patterns both at the proximal and distal anastomotic sites, and (ii) the wall shear stress distribution, which is an important factor that contributes to graft patency. METHODS: The three-dimensional coronary bypass models of the aorto-right coronary bypass and the aorto-left coronary bypass systems are constructed using computational fluid-dynamics software (Fluent 6.0.1). To have a better understanding of the flow dynamics at specific time instants of the cardiac cycle, quasi-steady flow simulations are performed, using a finite-volume approach. The data input to the models are the physiological measurements of flow-rates at (i) the aortic entrance, (ii) the ascending aorta, (iii) the left coronary artery, and (iv) the right coronary artery. RESULTS: The flow field and the wall shear stress are calculated throughout the cycle, but reported in this paper at two different instants of the cardiac cycle, one at the onset of ejection and the other during mid-diastole for both the right and left aorto-coronary bypass graft models. Plots of velocity-vector and the wall shear stress distributions are displayed in the aorto-graft-coronary arterial flow-field domain. We have shown (i) how the blocked coronary artery is being perfused in systole and diastole, (ii) the flow patterns at the two anastomotic junctions, proximal and distal anastomotic sites, and (iii) the shear stress distributions and their associations with arterial disease. CONCLUSION: The computed results have revealed that (i) maximum perfusion of the occluded artery occurs during mid-diastole, and (ii) the maximum wall shear-stress variation is observed around the distal anastomotic region. These results can enable the clinicians to have a better understanding of vein graft disease, and hopefully we can offer a solution to alleviate or delay the occurrence of vein graft disease

    Simulation, Identification and Statistical Variation in Cardiovascular Analysis (SISCA) - a Software Framework for Multi-compartment Lumped Modeling

    Get PDF
    Modeling approaches that are suitable to cover a wide range of real world scenarios in cardiovascular physiology could not be obtained so far, because many of the system parameters are uncertain or even unknown at all. The natural variability and statistical variation of cardiovascular system parameters in healthy and diseased conditions is assumed to be one of the characteristic features to understand cardiovascular diseases in more detail. Within this paper, a novel software framework for statistical variation, system identification, patient-specific simulation in cardiovascular system modeling is described by a multi-model statistical ensemble approach using dimension reduced multi-compartment models. The data driven approach is applied to model pre- and post-surgery clinical data sets from a patient (13 years old, 148cm, female) diagnosed with coarctation of aorta (CoA). A patient specific structure was obtained by the remapping of geometric parameters according to available MRI and metadata. Characteristic periodic boundary conditions were generated from pressure measurements, the systemic resistances and mean flow conditions at the outlets were adjusted subject to a weighting scheme, while systemic compliance and viscous parameters were fitted by reweighting the elastic modulus to the peak flows and pressure levels of all compartments. Archived model parametrization reflects the post-treatment data set and was used as a prior for modeling the pathologic pre-treatment state. According to geometry data, the stenosis was implemented for CoA modeling, such that the pressure drop was reproduced. In both scenarios, the simulated flows and pressure amplitudes are correctly reproduced by the simulation and stenosis and stent treatment were adequately reflected. Furthermore, the pre-treatment cross stenosis phase shift of the pulse wave is fairly well reproduced by the simulation. However, significant decrease of unrealistic phase shifts within the measurements was observed in the post-treatment after stent implementation, which is assumed to raise from specific systemic or measurement conditions that occurred during surgery. While patient specific modeling heavily depends on an effective and highly versatile modeling process, the methods and results presented in this paper suggest that the conditioning and uncertainty management of routine clinical data sets have to be further improved to obtain reasonable results in patient-specific cardiovascular modeling

    Untersuchung von Stroemung und Stofftransport in Mikrokapseln Zwischenbericht

    No full text
    SIGLEAvailable from TIB Hannover: F03B152 / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDeutsche Forschungsgemeinschaft (DFG), Bonn (Germany)DEGerman
    • …
    corecore