6 research outputs found

    Single-phase five-level multilevel inverter based on a transistors six-pack module

    Get PDF
    This article introduces a single-phase five-level multilevel inverter based on six switches and two transformers. The proposed converter requires a single dc input source with low voltage. The disposition of switches makes it possible to build the converter with a transistors six-pack module off-the-shelves, traditionally used to build three-phase inverters, which simplifies the manufacturing process. The converter increases the voltage with two transformers; for that reason, it does not require an auxiliary step-up converter. The use of transformers (with the transformer’s turns ratio) allows for using the same topology for several input voltage levels. To verify the operation of the proposed multilevel inverter, a computer-based simulation was performed with PSIM, a software that considers parasitic components. The results show that the proposed converter can work properly

    Single-Phase Five-Level Multilevel Inverter Based on a Transistors Six-Pack Module

    No full text
    This article introduces a single-phase five-level multilevel inverter based on six switches and two transformers. The proposed converter requires a single dc input source with low voltage. The disposition of switches makes it possible to build the converter with a transistors six-pack module off-the-shelves, traditionally used to build three-phase inverters, which simplifies the manufacturing process. The converter increases the voltage with two transformers; for that reason, it does not require an auxiliary step-up converter. The use of transformers (with the transformer’s turns ratio) allows for using the same topology for several input voltage levels. To verify the operation of the proposed multilevel inverter, a computer-based simulation was performed with PSIM, a software that considers parasitic components. The results show that the proposed converter can work properly

    Single-Phase Five-Level Multilevel Inverter Based on a Transistors Six-Pack Module

    No full text
    This article introduces a single-phase five-level multilevel inverter based on six switches and two transformers. The proposed converter requires a single dc input source with low voltage. The disposition of switches makes it possible to build the converter with a transistors six-pack module off-the-shelves, traditionally used to build three-phase inverters, which simplifies the manufacturing process. The converter increases the voltage with two transformers; for that reason, it does not require an auxiliary step-up converter. The use of transformers (with the transformer’s turns ratio) allows for using the same topology for several input voltage levels. To verify the operation of the proposed multilevel inverter, a computer-based simulation was performed with PSIM, a software that considers parasitic components. The results show that the proposed converter can work properly

    Effects of pre-operative isolation on postoperative pulmonary complications after elective surgery: an international prospective cohort study

    No full text

    Global Incidence and Risk Factors Associated With Postoperative Urinary Retention Following Elective Inguinal Hernia Repair

    No full text
    Importance Postoperative urinary retention (POUR) is a well-recognized complication of inguinal hernia repair (IHR). A variable incidence of POUR has previously been reported in this context, and contradictory evidence surrounds potential risk factors.Objective To ascertain the incidence of, explore risk factors for, and determine the health service outcomes of POUR following elective IHR.Design, Setting, and Participants The Retention of Urine After Inguinal Hernia Elective Repair (RETAINER I) study, an international, prospective cohort study, recruited participants between March 1 and October 31, 2021. This study was conducted across 209 centers in 32 countries in a consecutive sample of adult patients undergoing elective IHR.Exposure Open or minimally invasive IHR by any surgical technique, under local, neuraxial regional, or general anesthesia.Main Outcomes and Measures The primary outcome was the incidence of POUR following elective IHR. Secondary outcomes were perioperative risk factors, management, clinical consequences, and health service outcomes of POUR. A preoperative International Prostate Symptom Score was measured in male patients.Results In total, 4151 patients (3882 male and 269 female; median [IQR] age, 56 [43-68] years) were studied. Inguinal hernia repair was commenced via an open surgical approach in 82.2% of patients (n = 3414) and minimally invasive surgery in 17.8% (n = 737). The primary form of anesthesia was general in 40.9% of patients (n = 1696), neuraxial regional in 45.8% (n = 1902), and local in 10.7% (n = 446). Postoperative urinary retention occurred in 5.8% of male patients (n = 224), 2.97% of female patients (n = 8), and 9.5% (119 of 1252) of male patients aged 65 years or older. Risk factors for POUR after adjusted analyses included increasing age, anticholinergic medication, history of urinary retention, constipation, out-of-hours surgery, involvement of urinary bladder within the hernia, temporary intraoperative urethral catheterization, and increasing operative duration. Postoperative urinary retention was the primary reason for 27.8% of unplanned day-case surgery admissions (n = 74) and 51.8% of 30-day readmissions (n = 72).Conclusions The findings of this cohort study suggest that 1 in 17 male patients, 1 in 11 male patients aged 65 years or older, and 1 in 34 female patients may develop POUR following IHR. These findings could inform preoperative patient counseling. In addition, awareness of modifiable risk factors may help to identify patients at increased risk of POUR who may benefit from perioperative risk mitigation strategies
    corecore