4,567 research outputs found
Synergistic relationships among remote-sensing and geophysical media: Geological and hydrological applications
The synergistic relationships among LANDSAT imagery, Skylab photographs, and aerial photographs were useful for establishing areas of near surface bedrock. Lineaments were located on LANDSAT imagery and aerial photographs during 1978 and near surface water tables were to be located during 1980. Both of these subjects can be identified by remote sensing methods more reliably than individual outcrops, which are small and occur in a wide variety of environments with a wide range of responses. Bedrock outcrops themselves could not be resolved by any of the data sources used, nor did any combination of data sources specifically identify rock at the ground surface. The data sources could not simply be combined mathematically to produce a visual image of probable areas of near surface bedrock. Outcrops and near surface bedrock had to be verified visually at the site. Despite these drawbacks, a procedure for locating areas of near surface bedrock within which actual surface outcrops may occur was developed
Performance of charge-injection-device infrared detector arrays at low and moderate backgrounds
Three 2 x 64 element charge injection device infrared detector arrays were tested at low and moderate background to evaluate their usefulness for space based astronomical observations. Testing was conducted both in the laboratory and in ground based telescope observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3x10 sq root of W/Hz. Array well capacity was measured to be significantly smaller than predicted. The measured sensitivity, which compares well with that of nonintegrating discrete extrinsic silicon photoconductors, shows these arrays to be useful for certain astronomical observations. However, the measured readout efficiency and frequency response represent serious limitations in low background applications
Detector arrays for low-background space infrared astronomy
The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratory test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications
Effect of remobinant granulocyte-macrophage colony stimulating factor (GM-CSF) on leukopenia in AIDS
Self-consistent model for ambipolar tunneling in quantum-well systems
We present a self-consistent approach to describe ambipolar tunneling in
asymmetrical double quantum wells under steady-state excitation and extend the
results to the case of tunneling from a near-surface quantum well to surface
states. The results of the model compare very well with the behavior observed
in photoluminescence experiments in asymmetric double quantum
wells and in near-surface single quantum wells.Comment: 10 pages, REVTeX 3.
Towards Physical Hybrid Systems
Some hybrid systems models are unsafe for mathematically correct but
physically unrealistic reasons. For example, mathematical models can classify a
system as being unsafe on a set that is too small to have physical importance.
In particular, differences in measure zero sets in models of cyber-physical
systems (CPS) have significant mathematical impact on the mathematical safety
of these models even though differences on measure zero sets have no tangible
physical effect in a real system. We develop the concept of "physical hybrid
systems" (PHS) to help reunite mathematical models with physical reality. We
modify a hybrid systems logic (differential temporal dynamic logic) by adding a
first-class operator to elide distinctions on measure zero sets of time within
CPS models. This approach facilitates modeling since it admits the verification
of a wider class of models, including some physically realistic models that
would otherwise be classified as mathematically unsafe. We also develop a proof
calculus to help with the verification of PHS.Comment: CADE 201
The anomalous threshold, confinement, and an essential singularity in the heavy-light form factor
The analytic behavior of the heavy-light meson form factor is investigated
using several relativistic examples including unconfined, weakly confined, and
strongly confined mesons. It is observed that confinement erases the anomalous
threshold singularity and also induces an essential singularity at the normal
annihilation threshold. In the weak confinement limit, the "would be" anomalous
threshold contribution is identical to that of the real singularity on its
space-like side.Comment: Latex 2.09 with epsf.sty. 24 pages of text and 8 postscript figures.
Postscript version of complete paper will also be available soon at
http://phenom.physics.wisc.edu/pub/preprints/1997/madph-97-983 or at
ftp://phenom.physics.wisc.edu/pub/preprints/1997/madph-97-98
Platelet inhibitors versus anticoagulants for prevention of aorto-coronary bypass graft occlusion
The effects of the antiaggregant substance ticlopidine and of the anticoagulant acenocoumarol on patency rates of aorto-coronary bypass grafts were compared in a prospective randomized trial. Ticlopidine, 250 mg b.i.d. was administered orally from the first postoperative day till angiography, while anticoagulation with acenocoumarol was initiated on the second to third postoperative day. Side-effects of ticlopidine were rare and patient management with the standard dosage of this drug was easier than oral anticoagulation. From an initial group of 166 randomized patients 149 completed the trial by coronary angiography three months postoperatively. The 78 patients in the ticlopidine group showed a compliance of 85%. The average prothrombin time in the 71 patients receiving acenocoumarol was 26.9%. Detailed statistical analysis of the two study groups revealed no reason to doubt the correctness of randomization. Coronary angiography showed an average patency rate per patient of 84% with ticlopidine and of 82% with acenocoumarol. This and various other measures of graft occlusion did not reveal any substantial difference in graft patency of patients receiving ticlopidine or acenocoumarol. It is concluded that ticlopidine may well be used instead of anticoagulants forprevention of postoperative occlusion of aorto-coronary bypass graft
- …