15 research outputs found

    Nine years of plan of the day for cervical cancer:Plan library remains effective compared to fully online-adaptive techniques

    Get PDF
    Background and purpose: Since 2011, our center has been using a library-based Plan-of-the-Day (PotD) strategy for external beam radiotherapy of cervical cancer patients to reduce normal tissue dose while maintaining adequate target coverage. With the advent of fully online-adaptive techniques such as daily online-adaptive replanning, further dose reduction may be possible. However, it is unknown how this reduction relates to plan library approaches, and how the most recent PotD strategies relate to no adaptation. In this study we compare the performance of our current PotD strategy with non-adaptive and fully online-adaptive techniques in terms of target volume size and normal tissue sparing. Materials and methods: Treatment data of 376 patients treated with the PotD protocol between June 2011 and April 2020 were included. The size of the Planning Target Volumes (PTVs) was reconstructed for different strategies: full online adaptation, no adaptation, and the latest clinical version of the PotD protocol. Normal tissue sparing was estimated by the difference in margin volume to construct the PTV and the volume overlap of the PTV with bladder and rectum. Results: The current version of our PotD approach reduced the PTV margin volume by a median of 250 cm3 compared to no adaptation. Bladder-PTV overlap decreased from a median of 142 to 71 cm3, and from 39 to 16 cm3 for rectum-PTV. Fully online-adaptive approaches could further decrease the PTV volume by 144 cm3 using a 5 mm margin for residual errors. In this scenario, bladder-PTV overlap was reduced to 35 cm3 and rectum-PTV overlap to 11 cm3. Conclusion: The current version of the PotD protocol is an effective technique to improve normal tissue sparing compared to no adaptation. Further sparing can be achieved using fully online-adaptive techniques, but at the cost of a more complex workflow and with a potentially limited impact. PotD-type protocols can therefore be considered as a suitable alternative to fully online-adaptive approaches.</p

    The impact of bone marrow sparing on organs at risk dose for cervical cancer: a Pareto front analysis

    Get PDF
    Background and purposeTo quantify the increase in bladder and rectum dose of a bone marrow sparing (BMS) VMAT strategy for primary treatment of locally advanced cervical cancer (LACC).Materials and methodsTwenty patients with stage IB-IVA cervical cancer were selected for this study. The whole Pelvic Bones (PB) was taken as substitute for bone marrow. For every patient, Pareto-optimal plans were generated to explore the trade-off between rectum, bladder, and PB mean dose. The PB mean dose was decreased in steps of 1 Gy. For each step, the increase in rectum and bladder mean dose was quantified. The increase in mean dose of other OAR compared to no BMS was constrained to 1 Gy.ResultsIn total, 931 plans of 19 evaluable patients were analyzed. The average [range] mean dose of PB without BMS was 22.8 [20.7-26.2] Gy. When maximum BMS was applied, the average reduction in mean PB dose was 5.4 [3.0-6.8] Gy resulting in an average mean PB dose of 17.5 [15.8-19.8] Gy. For &lt;1 Gy increase in both the bladder and the rectum mean dose, the PB mean dose could be decreased by &gt;2 Gy, &gt;3 Gy, &gt;4 Gy, and &gt;5 Gy for 19/19, 13/19, 5/19, and 1/19 patients, respectively.ConclusionBased on the comprehensive three-dimensional Pareto front analysis, we conclude that 2-5 Gy BMS can be implemented without a clinically relevant increase in mean dose to other OAR. If BMS is too dominant, it results in a large increase in mean dose to other OAR. Therefore, we recommend implementing moderate BMS for the treatment of LACC patients with VMAT

    The impact of bone marrow sparing on organs at risk dose for cervical cancer:a Pareto front analysis

    Get PDF
    Background and purpose: To quantify the increase in bladder and rectum dose of a bone marrow sparing (BMS) VMAT strategy for primary treatment of locally advanced cervical cancer (LACC). Materials and methods: Twenty patients with stage IB-IVA cervical cancer were selected for this study. The whole Pelvic Bones (PB) was taken as substitute for bone marrow. For every patient, Pareto-optimal plans were generated to explore the trade-off between rectum, bladder, and PB mean dose. The PB mean dose was decreased in steps of 1 Gy. For each step, the increase in rectum and bladder mean dose was quantified. The increase in mean dose of other OAR compared to no BMS was constrained to 1 Gy. Results: In total, 931 plans of 19 evaluable patients were analyzed. The average [range] mean dose of PB without BMS was 22.8 [20.7-26.2] Gy. When maximum BMS was applied, the average reduction in mean PB dose was 5.4 [3.0-6.8] Gy resulting in an average mean PB dose of 17.5 [15.8-19.8] Gy. For &lt;1 Gy increase in both the bladder and the rectum mean dose, the PB mean dose could be decreased by &gt;2 Gy, &gt;3 Gy, &gt;4 Gy, and &gt;5 Gy for 19/19, 13/19, 5/19, and 1/19 patients, respectively. Conclusion: Based on the comprehensive three-dimensional Pareto front analysis, we conclude that 2-5 Gy BMS can be implemented without a clinically relevant increase in mean dose to other OAR. If BMS is too dominant, it results in a large increase in mean dose to other OAR. Therefore, we recommend implementing moderate BMS for the treatment of LACC patients with VMAT.</p

    Correlations between bone marrow radiation dose and hematologic toxicity in locally advanced cervical cancer patients receiving chemoradiation with cisplatin: a systematic review

    Get PDF
    Patients with locally advanced cervical cancer (LACC) treated with chemoradiation often experience hematologic toxicity (HT), as chemoradiation can induce bone marrow (BM) suppression. Studies on the relationship between BM dosimetric parameters and clinically significant HT might provide relevant indices for developing BM sparing (BMS) radiotherapy techniques. This systematic review studied the relationship between BM dose and HT in patients with LACC treated with primary cisplatin-based chemoradiation. A systematic search was conducted in Embase, Medline, and Web of Science. Eligibility criteria were treatment of LACC-patients with cisplatin-based chemoradiation and report of HT or complete blood cell count (CBC). The search identified 1346 papers, which were screened on title and abstract before two reviewers independently evaluated the full-text. 17 articles were included and scored according to a selection of the TRIPOD criteria. The mean TRIPOD score was 12.1 out of 29. Fourteen studies defining BM as the whole pelvic bone contour (PB) detected significant associations with V10 (3/14), V20 (6/14), and V40 (4/11). Recommended cut-off values were V10 > 95–75%, V20 > 80–65%, and V40 > 37–28%. The studies using lower density marrow spaces (PBM) or active bone marrow (ABM) as a proxy for BM only found limited associations with HT. Our study was the first literature review providing an overview of articles evaluating the correlation between BM and HT for patients with LACC undergoing cisplatin-based chemoradiation. There is a scarcity of studies independently validating developed prediction models between BM dose and HT. Future studies may use PB contouring to develop normal tissue complication probability models

    Multi-center analysis of machine-learning predicted dose parameters in brachytherapy for cervical cancer

    Get PDF
    Background and purpose: Image-guided adaptive brachytherapy (IGABT) is a key component in the treatment of cervical cancer, but the nature of the clinical workflow makes it vulnerable to suboptimal plans, as the theoretical optimal plan depends heavily on organ configuration. Patient anatomy-based quality-assurance (QA) with overlap volume histograms (OVHs) is a promising tool to detect such suboptimal plans, and in this analysis its suitability as a multi-institutional clinical QA tool is investigated. Materials and methods: A total of 223 plans of 145 patients treated in accordance with the current state-of-the-art IGABT protocols from UMC Utrecht (UMCU) and Erasmus MC (EMC) were included. Machine-learning models were trained to predict dose D2cm3 to bladder, rectum, sigmoid and small bowel with the help of OVHs. For this strategy, points are sampled on the organs-at-risk (OARs), and the distances of the sampled points to the target are computed and combined in a histogram. Machine-learning models can then be trained to predict dose-volume histograms (DVHs) for unseen data. Single-center model robustness to needle use and applicator type and multi-center model translatability were investigated. Performance of models was assessed by the difference between planned (clinical) and predicted D2cm3 values. Results: Intra-validation of UMCU data demonstrated OVH model robustness to needle use and applicator type. The model trained on UMCU data was found to be robust within the same protocol on EMC data, for all investigated OARs. Mean squared error between planned and predicted D2cm3 values of OARs ranged between 0.13 and 0.40 Gy within the same protocol, indicating model translatability. For the former protocol cohort of Erasmus MC large deviations were found between the planned and predicted D2cm3 values, indicating plan deviation from protocol. Mean squared error for this cohort ranged from 0.84 to 4.71 Gy. Conclusion: OVH-based models can provide a solid basis for multi-institutional QA when trained on a sufficiently strict protocol. Further research will quantify the model's impact as a QA tool

    Accuracy of dwell position detection with a combined electromagnetic tracking brachytherapy system for treatment verification in pelvic brachytherapy

    No full text
    Background and purpose: To investigate the accuracy of dwell position detection with a combined electromagnetic tracking (EMT) brachytherapy (BT) system for treatment verification, by quantifying positional errors due to EM field interference in typical pelvic BT clinical settings. Materials and methods: Dedicated prostate and cervix BT phantoms were imaged with CT. For the cervix phantom, the Utrecht applicator + interstitial catheters were used. The implants were reconstructed and treatment plans were created with 270/65 dwell positions for the prostate/cervix phantom. Next, EMT experiments were performed in clinical BT settings using a prototype of a combined EMT/BT system. We quantified positional errors due to EM field interference from surrounding equipment by comparing planned and EMT-measured dwell positions. The mean residual error between planned and EMT-measured dwell positions was calculated in the prostate interstitial catheters and in the whole cervix implant including the applicator. For the cervix phantom, the analysis was repeated for only the interstitial catheters. Results: Mean residual errors of less than 0.5/0.4 mm in the prostate/cervix catheters were found. For the whole cervix implant including the applicator, large deviations up to 2.4 mm were found. Compared to the interference free set-up, the CT and patient bed environments showed larger residual errors in the interstitial catheters, but residual errors remained <1 mm in all cases. Conclusion: Dwell position detection with the combined system in interstitial catheters is sufficiently accurate to perform EMT-based treatment verification. The effect of EM interference from the surrounding equipment was limited
    corecore