70 research outputs found

    Cardiac Radionuclide Imaging in Rodents: A Review of Methods, Results, and Factors at Play.

    Get PDF
    The interest around small-animal cardiac radionuclide imaging is growing as rodent models can be manipulated to allow the simulation of human diseases. In addition to new radiopharmaceuticals testing, often researchers apply well-established probes to animal models, to follow the evolution of the target disease. This reverse translation of standard radiopharmaceuticals to rodent models is complicated by technical shortcomings and by obvious differences between human and rodent cardiac physiology. In addition, radionuclide studies involving small animals are affected by several extrinsic variables, such as the choice of anesthetic. In this paper, we review the major cardiac features that can be studied with classical single-photon and positron-emitting radiopharmaceuticals, namely, cardiac function, perfusion and metabolism, as well as the results and pitfalls of small-animal radionuclide imaging techniques. In addition, we provide a concise guide to the understanding of the most frequently used anesthetics such as ketamine/xylazine, isoflurane, and pentobarbital. We address in particular their mechanisms of action and the potential effects on radionuclide imaging. Indeed, cardiac function, perfusion, and metabolism can all be significantly affected by varying anesthetics and animal handling conditions

    First in-human radiation dosimetry of (68)Ga-NODAGA-RGDyK.

    Get PDF
    Integrin-targeting radiopharmaceuticals have potential broad applications, spanning from cancer theranostics to cardiovascular diseases. We have previously reported preclinical dosimetry results of (68)Ga-NODAGA-RGDyK in mice. This study presents the first human dosimetry of (68)Ga-NODAGA-RGDyK in the five consecutive patients included in a clinical imaging protocol of carotid atherosclerotic plaques. Five male patients underwent whole-body time-of-flight (TOF) PET/CT scans 10, 60 and 120 min after tracer injection (200 MBq). Quantification of (68)Ga activity concentration was first validated by a phantom study. To be used as input in OLINDA/EXM, time-activity curves were derived from manually drawn regions of interest over the following organs: brain, thyroid, lungs, heart, liver, spleen, stomach, kidneys, red marrow, pancreas, small intestine, colon, urinary bladder and whole body. A separate dosimetric analysis was performed for the choroid plexuses. Female dosimetry was extrapolated from male data. Effective doses (EDs) were estimated according to both ICRP60 and ICRP103 assuming 30-min and 1-h voiding cycles. The body regions receiving the highest dose were urinary bladder, kidneys and choroid plexuses. For a 30-min voiding cycle, the EDs were 15.7 and 16.5 μSv/MBq according to ICRP60 and ICRP103, respectively. The extrapolation to female dosimetry resulted in organ absorbed doses 17% higher than those of male patients, on average. The 1-h voiding cycle extrapolation resulted in EDs of 19.3 and 19.8 μSv/MBq according to ICRP60 and ICRP103, respectively. A comparison is made with previous mouse dosimetry and with other human studies employing different RGD-based radiopharmaceuticals. According to ICRP60/ICRP103 recommendations, an injection of 200 MBq (68)Ga-NODAGA-RGDyK leads to an ED in man of 3.86/3.92 mSv. For future therapeutic applications, specific attention should be directed to delivered dose to kidneys and potentially also to the choroid plexuses. Clinical trial.gov, NCT01608516

    The contest between internal and external-beam dosimetry: The Zeno's paradox of Achilles and the tortoise.

    Get PDF
    Radionuclide therapy, also called molecular radiotherapy (MRT), has come of age, with several novel radiopharmaceuticals being approved for clinical use or under development in the last decade. External beam radiotherapy (EBRT) is a well-established treatment modality, with about half of all oncologic patients expected to receive at least one external radiation treatment over their disease course. The efficacy and the toxicity of both types of treatment rely on the interaction of radiation with biological tissues. Dosimetry played a fundamental role in the scientific and technological evolution of EBRT, and absorbed doses to the target and to the organs at risk are calculated on a routine basis. In contrast, in MRT the usefulness of internal dosimetry has long been questioned, and a structured path to include absorbed dose calculation is missing. However, following a similar route of development as EBRT, MRT treatments could probably be optimized in a significant proportion of patients, likely based on dosimetry and radiobiology. In the present paper we describe the differences and the similarities between internal and external-beam dosimetry in the context of radiation treatments, and we retrace the main stages of their development over the last decades

    Research practice development for nuclear medicine technologists: an innovative experience

    Get PDF
    Introduction - European nuclear medicine technologist’s education is delivered by Higher Education Institutions and students obtain a grade of Bachelor of Sciences (BSc), during which they are initiated to research during their studies. Once BSc nuclear medicine technologists are in professional practice, they have very few opportunities to develop a real research experience and they rather become passive users than active contributors the growth of scientific knowledge in nuclear medicine. Aim - To describe and discuss an innovative educational and professional experience aimed in strengthen research knowledge, skills and competencies of former nuclear medicine technologists student in the context of an international mobility stay

    First in-human radiation dosimetry of the gastrin-releasing peptide (GRP) receptor antagonist (68)Ga-NODAGA-MJ9.

    Get PDF
    Gastrin-releasing peptide receptor antagonists have promise in theranostics of several highly incident tumours, including prostate and breast. This study presents the first human dosimetry of <sup>68</sup> Ga-NODAGA-MJ9 in the first five consecutive patients with recurrent prostate cancer included in a dual-tracer positron emission tomography (PET) protocol. Five male patients with biochemical relapse of prostate adenocarcinoma underwent four whole-body time-of-flight PET/CT scans within 2 h after tracer injection. To be used as input in OLINDA/EXM 2.0, time-integrated activity coefficients were derived from manually drawn regions of interest over the following body regions: brain, thyroid, lungs, heart, liver, gallbladder, spleen, stomach, kidneys, adrenals, red marrow, pancreas, intestines, urinary bladder and whole body. Organ absorbed doses and effective dose (ED) were calculated with OLINDA/EXM 2.0 using the NURBS voxelized phantoms adjusted to the ICRP-89 organ masses and ICRP103 tissue-weighting factors. Additional absorbed dose estimations were performed with OLINDA/EXM 1.1 to be comparable with similar previous publications. The body regions receiving the highest absorbed doses were the pancreas, the urinary bladder wall, the small intestine and the kidneys (260, 69.8, 38.8 and 34.8 μGy/MBq respectively). The ED considering a 30-min urinary voiding cycle was 17.6 μSv/MBq in male patients. The increment of voiding time interval produced a significant increase of absorbed doses in bladder, prostate and testes, as well as an increase of ED. ED also increased if calculated with OLINDA/EXM 1.1. These results have been discussed in view of similar publications on bombesin analogues or on other commonly used theranostic peptides. The pancreas is the most irradiated organ after the injection of <sup>68</sup> Ga-NODAGA-MJ9, followed by the urinary bladder wall, the small intestine and the kidneys. ED is in the same range of other common <sup>68</sup> Ga-labelled peptides. Differences with similarly published studies on bombesin analogues exist, and are mainly dependent on the methodology used for absorbed dose calculations. Clinicaltrial.Gov identifier: NCT02111954 , posted on 11/042014

    Dosimetry of nuclear medicine therapies: current controversies and impact on treatment optimization.

    No full text
    Nuclear medicine therapeutic procedures have considerably expanded over the last few years, and their number is expected to grow exponentially in the future. Internal dosimetry has significantly developed as well, but has not yet been uniformly accepted as a valuable tool for prediction of therapeutic efficacy and toxicity. In this paper, we briefly summarize some of the arguments about the implementation of internal dosimetry in clinical practice. In addition, we provide a few examples of radionuclide anticancer therapies for which internal dosimetry demonstrated a significant impact on treatment optimization and patient outcome

    Thermal conductivity of silicon carbide at high temperatures

    No full text
    corecore