20 research outputs found

    Device-detected atrial fibrillation and risk for stroke: an analysis of >10 000 patients from the SOS AF project (Stroke preventiOn Strategies based on Atrial Fibrillation information from implanted devices)

    Get PDF
    Objective: The aim of this study was to assess the association between maximum daily atrial fibrillation (AF) burden and risk of ischaemic stroke. Background: Cardiac implanted electronic devices (CIEDs) enhance detection of AF, providing a comprehensive measure of AF burden. Design, setting, and patients A pooled analysis of individual patient data from five prospective studies was performed. Patients without permanent AF, previously implanted with CIEDs, were included if they had at least 3 months of follow-up. A total of 10 016 patients (median age 70 years) met these criteria. The risk of ischaemic stroke associated with pre-specified cut-off points of AF burden (5 min, 1, 6, 12, and 23 h, respectively) was assessed. Results: During a median follow-up of 24 months, 43% of 10 016 patients experienced at least 1 day with at least 5 min of AF burden and for them the median time to the maximum AF burden was 6 months (inter-quartile range: 1.3–14). A Cox regression analysis adjusted for the CHADS2 score and anticoagulants at baseline demonstrated that AF burden was an independent predictor of ischaemic stroke. Among the thresholds of AF burden that we evaluated, 1 h was associated with the highest hazard ratio (HR) for ischaemic stroke, i.e. 2.11 (95% CI: 1.22–3.64, P = 0.008). Conclusions: Device-detected AF burden is associated with an increased risk of ischaemic stroke in a relatively unselected population of CIEDs patients. This finding may add to the basis for timely and clinically appropriate decision-making on anticoagulation treatment

    Device-detected subclinical atrial tachyarrhythmias: Definition, implications and management - An European Heart Rhythm Association (EHRA) consensus document, endorsed by Heart Rhythm Society (HRS), Asia Pacific Heart Rhythm Society (APHRS) and Sociedad Latinoamericana de Estimulaci\uf3n Card\uedaca y Electrofisiolog\ueda (SOLEACE)

    Get PDF
    Among atrial tachyarrhythmias (AT), atrial fibrillation (AF) is the most common sustained arrhythmia. Many patients with AT have no symptoms during brief or even extended periods of the arrhythmia, making detection in patients at risk for stroke challenging. Subclinical atrial tachyarrhythmia and asymptomatic or silent atrial tachyarrhythmia often precede the development of clinical AF. Clinical AF and subclinical atrial fibrillation (SCAF) are associated with an increased risk of thromboembolism. Indeed, in many cases, SCAF is discovered only after complications such as ischaemic stroke or congestive heart failure have occurred

    Response to Letter by Willey

    No full text

    Detection of new atrial fibrillation in patients with cardiac implanted electronic devices and factors associated with transition to higher device-detected atrial fibrillation burden

    No full text
    Background: In patients with cardiac implanted electronic devices, detection of new atrial fibrillation (AF) is associated with an increased risk of stroke. Objective: To characterize daily AF burden at first detection and the rate of temporal transition to higher device-detected AF burden. Methods: A pooled analysis of data from 3 prospective projects was analyzed, and 6580 patients (mean age 68 ± 12 years, 72% male) with no history of AF and no use of anticoagulants at baseline were identified. Various thresholds of daily AF burden (5 minutes and 1, 6, 12, and 23 hours) were analyzed. Results: Among the study population of 6580 patients, a new AF, with an AF burden of ≥5 minutes, was detected in 2244 patients (34%) during a follow-up period of 2.4 ± 1.7 years. Among these patients, 1091 (49.8%) transitioned to a higher AF-burden threshold during follow-up. A higher duration of daily AF burden manifest at first detection and CHADS2 score ≥2 were associated with faster transition to a subsequent higher burden. Approximately 24% of patients transitioned from a lower threshold to a daily AF burden of ≥23 hours during follow-up. Conclusion: More than one-third of patients with no history of AF developed device-detected AF, with attainment of different thresholds of daily AF burden over time. Continuous long-term monitoring, especially when the initial detection corresponds to a higher daily AF burden and the CHADS2 score is ≥2, could support timely clinical decisions on anticoagulation by capturing transitions to higher AF-burden thresholds

    Consumer-Led Screening for Atrial Fibrillation: Frontier Review of the AF-SCREEN International Collaboration.

    No full text
    The technological evolution and widespread availability of wearables and handheld ECG devices capable of screening for atrial fibrillation (AF), and their promotion directly to consumers, has focused attention of health care professionals and patient organizations on consumer-led AF screening. In this Frontiers review, members of the AF-SCREEN International Collaboration provide a critical appraisal of this rapidly evolving field to increase awareness of the complexities and uncertainties surrounding consumer-led AF screening. Although there are numerous commercially available devices directly marketed to consumers for AF monitoring and identification of unrecognized AF, health care professional-led randomized controlled studies using multiple ECG recordings or continuous ECG monitoring to detect AF have failed to demonstrate a significant reduction in stroke. Although it remains uncertain if consumer-led AF screening reduces stroke, it could increase early diagnosis of AF and facilitate an integrated approach, including appropriate anticoagulation, rate or rhythm management, and risk factor modification to reduce complications. Companies marketing AF screening devices should report the accuracy and performance of their products in high- and low-risk populations and avoid claims about clinical outcomes unless improvement is demonstrated in randomized clinical trials. Generally, the diagnostic yield of AF screening increases with the number, duration, and temporal dispersion of screening sessions, but the prognostic importance may be less than for AF detected by single-time point screening, which is largely permanent, persistent, or high-burden paroxysmal AF. Consumer-initiated ECG recordings suggesting possible AF always require confirmation by a health care professional experienced in ECG reading, whereas suspicion of AF on the basis of photoplethysmography must be confirmed with an ECG. Consumer-led AF screening is unlikely to be cost-effective for stroke prevention in the predominantly young, early adopters of this technology. Studies in older people at higher stroke risk are required to demonstrate both effectiveness and cost-effectiveness. The direct interaction between companies and consumers creates new regulatory gaps in relation to data privacy and the registration of consumer apps and devices. Although several barriers for optimal use of consumer-led screening exist, results of large, ongoing trials, powered to detect clinical outcomes, are required before health care professionals should support widespread adoption of consumer-led AF screening

    2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure

    No full text
    Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified
    corecore