46 research outputs found
Genetic and neurodevelopmental spectrum of SYNGAP1-associated intellectual disability and epilepsy
Objective: We aimed to delineate the neurodevelopmental spectrum associated with SYNGAP1 mutations and to investigate genotype–phenotype correlations.
Methods: We sequenced the exome or screened the exons of SYNGAP1 in a total of 251 patients with neurodevelopmental disorders. Molecular and clinical data from patients with SYNGAP1 mutations from other centres were also collected, focusing on developmental aspects and the associated epilepsy phenotype. A review of SYNGAP1 mutations published in the literature was also performed.
Results: We describe 17 unrelated affected individuals carrying 13 different novel loss-of-function SYNGAP1 mutations. Developmental delay was the first manifestation of SYNGAP1-related encephalopathy; intellectual disability became progressively obvious and was associated with autistic behaviours in eight patients. Hypotonia and unstable gait were frequent associated neurological features. With the exception of one patient who experienced a single seizure, all patients had epilepsy, characterised by falls or head drops due to atonic or myoclonic seizures, (myoclonic) absences and/or eyelid myoclonia. Triggers of seizures were frequent (n=7). Seizures were pharmacoresistant in half of the patients. The severity of the epilepsy did not correlate with the presence of autistic features or with the severity of cognitive impairment. Mutations were distributed throughout the gene, but spared spliced 3′ and 5′ exons. Seizures in patients with mutations in exons 4–5 were more pharmacoresponsive than in patients with mutations in exons 8–15.
Conclusions: SYNGAP1 encephalopathy is characterised by early neurodevelopmental delay typically preceding the onset of a relatively recognisable epilepsy comprising generalised seizures (absences, myoclonic jerks) and frequent triggers
Recommended from our members
Electron microscopy of biological macromolecules: Bridging the gap between what physics allows and what we currently can get
The resolution achieved in low-dose electron microscopy of biological macromolecules is significantly worse than what can be obtained on the same microscopes with more robust specimens. When two-dimensional crystals are used, it is also apparent that the high-resolution image contrast is much less than what it could be if the images were perfect. Since specimen charging is one factor that might limit the contrast and resolution achieved with biological specimens, we have investigated the use of holey support films that have been coated with a metallic film before depositing specimens onto a thin carbon film that is suspended over the holes. Monolayer crystals of paraffin (C44H90) are used as a test specimen for this work because of the relative ease in imaging Bragg spacings at ~;0.4 nm resolution, the relative ease of measuring the contrast in these images, and the similar degree of radiation sensitivity of these crystals when compared to biological macromolecules. A metallic coating on the surrounding support film does, indeed, produce a significant improvement in the high-resolution contrast for a small fraction of the images. The majority of images show little obvious improvement, however, and even the coated area of the support film continues to show a significant amount of beam-induced movement under low-dose conditions. The fact that the contrast in the best images can be as much as 25 percent-35 percent of what it would be in a perfect image is nevertheless encouraging, demonstrating that it should be possible, in principle, to achieve the same performance for every image. Routine data collection of this quality would make it possible to determine the structure of large, macromolecular complexes without the need to grow crystals of these difficult specimen materials
Recommended from our members
Electron microscopy of biological macromolecules: Bridging the gap between what physics allows and what we currently can get
The resolution achieved in low-dose electron microscopy of biological macromolecules is significantly worse than what can be obtained on the same microscopes with more robust specimens. When two-dimensional crystals are used, it is also apparent that the high-resolution image contrast is much less than what it could be if the images were perfect. Since specimen charging is one factor that might limit the contrast and resolution achieved with biological specimens, we have investigated the use of holey support films that have been coated with a metallic film before depositing specimens onto a thin carbon film that is suspended over the holes. Monolayer crystals of paraffin (C44H90) are used as a test specimen for this work because of the relative ease in imaging Bragg spacings at ~;0.4 nm resolution, the relative ease of measuring the contrast in these images, and the similar degree of radiation sensitivity of these crystals when compared to biological macromolecules. A metallic coating on the surrounding support film does, indeed, produce a significant improvement in the high-resolution contrast for a small fraction of the images. The majority of images show little obvious improvement, however, and even the coated area of the support film continues to show a significant amount of beam-induced movement under low-dose conditions. The fact that the contrast in the best images can be as much as 25 percent-35 percent of what it would be in a perfect image is nevertheless encouraging, demonstrating that it should be possible, in principle, to achieve the same performance for every image. Routine data collection of this quality would make it possible to determine the structure of large, macromolecular complexes without the need to grow crystals of these difficult specimen materials
Recommended from our members
STROBOSCOPIC IMAGE CAPTURE: REDUCING THE DOSE PER FRAME BY A FACTOR OF 30 DOES NOT PREVENT BEAM-INDUCED SPECIMEN MOVEMENT IN PARAFFIN
Beam-induced specimen movement may be the major factor that limits the quality of high-resolution images of organic specimens. One of the possible measures to improve the situation that was proposed by Henderson and Glaeser (Henderson and Glaeser, 1985), which we refer to here as 'stroboscopic image capture', is to divide the normal exposure into many successive frames, thus reducing the amount of electron exposure--and possibly the amount of beam-induced movement--per frame. The frames would then be aligned and summed. We have performed preliminary experiments on stroboscopic imaging using a 200-kV electron microscope that was equipped with a high dynamic range CCD camera for image recording and a liquid N{sub 2}-cooled cryoholder. Single-layer paraffin crystals on carbon film were used as a test specimen. The ratio F(g)/F(0) of paraffin reflections, calculated from the images, serves as our criterion for the image quality. In the series that were evaluated, no significant improvement of the F{sub image}(g)/F{sub image}(0) ratio was found, even though the electron exposure per frame was reduced by a factor of 30. A frame-to-frame analysis of image distortions showed that considerable beam-induced movement had still occurred during each frame. In addition, the paraffin crystal lattice was observed to move relative to the supporting carbon film, a fact that cannot be explained as being an electron-optical effect caused by specimen charging. We conclude that a significant further reduction of the dose per frame (than was possible with this CCD detector) will be needed in order to test whether the frame-to-frame changes ultimately become small enough for stroboscopic image capture to show its potential
Recommended from our members
DESIGN OF A MICROFABRICATED, TWO-ELECTRODE PHASE-CONTRAST ELEMENT SUITABLE FOR ELECTRON MICROSCOPY
Recommended from our members
DESIGN OF A MICROFABRICATED, TWO-ELECTRODE PHASE-CONTRAST ELEMENT SUITABLE FOR ELECTRON MICROSCOPY
A miniature electrostatic element has been designed to selectively apply a ninety-degree phase shift to the unscattered beam in the back focal plane of the objective lens, in order to realize Zernike-type, in-focus phase contrast in an electron microscope. The design involves a cylindrically shaped, biased-voltage electrode, which is surrounded by a concentric grounded electrode. Electrostatic calculations have been used to determine that the fringing fields in the region of the scattered electron beams will cause a negligible phase shift as long as the ratio of electrode length to the transverse feature-size is greater than 5:1. Unlike the planar, three-electrode einzel lens originally proposed by Boersch for the same purpose, this new design does not require insulating layers to separate the biased and grounded electrodes, and it can thus be produced by a very simple microfabrication process. Scanning electron microscope images confirm that mechanically robust devices with feature sizes of {approx}1 {micro}m can be easily fabricated. Preliminary experimental images demonstrate that these devices do apply a 90-degree phase shift between the scattered and unscattered electrons, as expected
Ranking TEM cameras by their response to electron shot noise.
We demonstrate two ways in which the Fourier transforms of images that consist solely of randomly distributed electrons (shot noise) can be used to compare the relative performance of different electronic cameras. The principle is to determine how closely the Fourier transform of a given image does, or does not, approach that of an image produced by an ideal camera, i.e. one for which single-electron events are modeled as Kronecker delta functions located at the same pixels where the electrons were incident on the camera. Experimentally, the average width of the single-electron response is characterized by fitting a single Lorentzian function to the azimuthally averaged amplitude of the Fourier transform. The reciprocal of the spatial frequency at which the Lorentzian function falls to a value of 0.5 provides an estimate of the number of pixels at which the corresponding line-spread function falls to a value of 1/e. In addition, the excess noise due to stochastic variations in the magnitude of the response of the camera (for single-electron events) is characterized by the amount to which the appropriately normalized power spectrum does, or does not, exceed the total number of electrons in the image. These simple measurements provide an easy way to evaluate the relative performance of different cameras. To illustrate this point we present data for three different types of scintillator-coupled camera plus a silicon-pixel (direct detection) camera
Recommended from our members
Ranking TEM cameras by their response to electron shot noise.
We demonstrate two ways in which the Fourier transforms of images that consist solely of randomly distributed electrons (shot noise) can be used to compare the relative performance of different electronic cameras. The principle is to determine how closely the Fourier transform of a given image does, or does not, approach that of an image produced by an ideal camera, i.e. one for which single-electron events are modeled as Kronecker delta functions located at the same pixels where the electrons were incident on the camera. Experimentally, the average width of the single-electron response is characterized by fitting a single Lorentzian function to the azimuthally averaged amplitude of the Fourier transform. The reciprocal of the spatial frequency at which the Lorentzian function falls to a value of 0.5 provides an estimate of the number of pixels at which the corresponding line-spread function falls to a value of 1/e. In addition, the excess noise due to stochastic variations in the magnitude of the response of the camera (for single-electron events) is characterized by the amount to which the appropriately normalized power spectrum does, or does not, exceed the total number of electrons in the image. These simple measurements provide an easy way to evaluate the relative performance of different cameras. To illustrate this point we present data for three different types of scintillator-coupled camera plus a silicon-pixel (direct detection) camera