1,608 research outputs found

    Photovoltaic power systems workshop

    Get PDF
    Discussions are presented on apparent deficiencies in NASA planning and technology development relating to a standard power module (25-35 kW) and to future photovoltaic power systems in general. Topics of discussion consider the following: (1) adequate studies on power systems; (2) whether a standard power system module should be developed from a standard spacecraft; (3) identification of proper approaches to cost reduction; (4) energy storage avoidance; (5) attitude control; (6) thermal effects of heat rejection on solar array configuration stability; (7) assembly of large power systems in space; and (8) factoring terrestrial photovoltaic work into space power systems for possible payoff

    Alien Registration- Given, Robert J. (Millinocket, Penobscot County)

    Get PDF
    https://digitalmaine.com/alien_docs/7210/thumbnail.jp

    Factors affecting the operation of laser-triggered gas switch (LTGS) with multi-electrode spark gap

    Get PDF
    Multi-electrode spark switches can be used for switching applications at elevated voltages or for command triggering. Symmetrical field graded electrodes allow the electrical stress across individual gaps to be controlled, thus maximising the hold off voltage and reducing switch pre-fire. The paper considers some aspects of multielectrode switch design and their influence on switching behavior. Non-symmetrical, uni-directional electrode topologies can be employed with advantages over traditional symmetrical design. The choice of working gas and gas pressure can influence switching performance in terms of delay-time and jitter. Transient analysis of switch characteristics has been undertaken in order to understand multi-electrode switching

    The triggered behavior of a controlled corona stabilised cascade switch

    Get PDF
    Corona stabilised switches have been shown to have advantages in pulse power switching applications due to their high repetition rates and low jitter. Work performed in recent years by the High Voltage Technologies Group within the Department of Electronic and Electrical Engineering at the University of Strathclyde has shown that the operating voltage range of such switches can be extended by using a multi-gap cascade configuration. One particular multi-gap topology was shown to operate under pressure at 100 kV with a switching jitter of 2ns. It has since been shown that by modifying the topology of the corona sources on the electrodes, it is possible to control the grading of the voltage distribution across the gaps in the cascade. The voltages across each gap and the self-break behaviour of the cascade were found to be in close agreement with the values predicted from the corona emission characteristics for the tested electrode topologies. This paper reports on a further examination of the behaviour of the corona controlled switching topology, where triggered operation of the switch has been investigated for different voltage distributions across the cascade gaps

    Time-dependent gravity in southern California, May 1974 - Apr 1979

    Get PDF
    Gravity measurements were coordinated with the long baseline three dimensional geodetic measurements of the Astronomical Radio Interferometric Earth Surveying project which used radio interferometry with extra-galactic radio sources. Gravity data from 28 of the stations had a single reading standard deviation of 11 microgal which gives a relative single determination between stations a standard deviation of 16 microgal. The largest gravity variation observed, 80 microgal, correlated with nearby waterwell variations and with smoothed rainfall. Smoothed rainfall data appeared to be a good indicator of the qualitative response of gravity to changing groundwater levels at other suprasediment stations, but frequent measurement of gravity at a station was essential until the quantitative calibration of the station's response to groundwater variations was accomplished

    Surface flashover of oil-immersed dielectric materials in uniform and non-uniform fields

    Get PDF
    The applied electrical fields required to initiate surface flashover of different types of dielectric material immersed in insulating oil have been investigated, by applying impulses of increasing peak voltage until surface flashover occurred. The behavior of the materials in repeatedly over-volted gaps was also analyzed in terms of breakdown mode (some bulk sample breakdown behaviour was witnessed in this regime), time to breakdown, and breakdown voltage. Cylindrical samples of polypropylene, low-density polyethylene, ultra-high molecular weight polyethylene, and Rexolite, were held between two electrodes immersed in insulating oil, and subjected to average applied electrical fields up to 870 kV/cm. Tests were performed in both uniform- and non-uniform-fields, and with different sample topologies. In applied field measurements, polypropylene required the highest levels of average applied field to initiate flashover in all electrode configurations tested, settling at similar to 600 kV/cm in uniform fields, and similar to 325 kV/cm in non-uniform fields. In over-volted point-plane gaps, ultra-high molecular weight polyethylene exhibited the longest pre-breakdown delay times. The results will provide comparative data for system designers for the appropriate choice of dielectric materials to act as insulators for high-voltage, pulsed-power machines

    Probing Disordered Substrates by Imaging the Adsorbate in its Fluid Phase

    Get PDF
    Several recent imaging experiments access the equilibrium density profiles of interacting particles confined to a two-dimensional substrate. When these particles are in a fluid phase, we show that such data yields precise information regarding substrate disorder as reflected in one-point functions and two-point correlations of the fluid. Using Monte Carlo simulations and replica generalizations of liquid state theories, we extract unusual two-point correlations of time-averaged density inhomogeneities induced by disorder. Distribution functions such as these have not hitherto been measured but should be experimentally accessible.Comment: 10 pages revtex 4 figure

    Barriers to mental health service use among distressed family caregivers of lung cancer patients

    Get PDF
    Although family caregivers of patients with lung and other cancers show high rates of psychological distress, they underuse mental health services. This qualitative study aimed to identify barriers to mental health service use among 21 distressed family caregivers of lung cancer patients. Caregivers had not received mental health services during the patient's initial months of care at a comprehensive cancer centre in New York City. Thematic analysis of interview data was framed by Andersen's model of health service use and Corrigan's stigma theory. Results of our analysis expand Andersen's model by providing a description of need variables (e.g. psychiatric symptoms), enabling factors (e.g. finances), and psychosocial factors associated with caregivers' non-use of mental health services. Regarding psychosocial factors, caregivers expressed negative perceptions of mental health professionals and a desire for independent management of emotional concerns. Additionally, caregivers perceived a conflict between mental health service use and the caregiving role (e.g. prioritising the patient's needs). Although caregivers denied stigma associated with service use, their anticipated negative self-perceptions if they were to use services suggest that stigma may have influenced their decision to not seek services. Findings suggest that interventions to improve caregivers' uptake of mental health services should address perceived barriers

    Theory of continuum percolation III. Low density expansion

    Full text link
    We use a previously introduced mapping between the continuum percolation model and the Potts fluid (a system of interacting s-states spins which are free to move in the continuum) to derive the low density expansion of the pair connectedness and the mean cluster size. We prove that given an adequate identification of functions, the result is equivalent to the density expansion derived from a completely different point of view by Coniglio et al. [J. Phys A 10, 1123 (1977)] to describe physical clustering in a gas. We then apply our expansion to a system of hypercubes with a hard core interaction. The calculated critical density is within approximately 5% of the results of simulations, and is thus much more precise than previous theoretical results which were based on integral equations. We suggest that this is because integral equations smooth out overly the partition function (i.e., they describe predominantly its analytical part), while our method targets instead the part which describes the phase transition (i.e., the singular part).Comment: 42 pages, Revtex, includes 5 EncapsulatedPostscript figures, submitted to Phys Rev
    • …
    corecore