3,151 research outputs found

    Dynamics of coreless vortices and rotation-induced dissipation peak in superfluid films on rotating porous substrates

    Full text link
    We analyze dynamics of 3D coreless vortices in superfluid films covering porous substrates. The 3D vortex dynamics is derived from the 2D dynamics of the film. The motion of a 3D vortex is a sequence of jumps between neighboring substrate cells, which can be described, nevertheless, in terms of quasi-continuous motion with average vortex velocity. The vortex velocity is derived from the dissociation rate of vortex-antivortex pairs in a 2D film, which was developed in the past on the basis of the Kosterlitz-Thouless theory. The theory explains the rotation-induced dissipation peak in torsion-oscillator experiments on 4^4He films on rotating porous substrates and can be used in the analysis of other phenomena related to vortex motion in films on porous substrates.Comment: 8 pages, 3 figures submitted to Phys. Rev.

    Non-contrast renal magnetic resonance imaging to assess perfusion and corticomedullary differentiation in health and chronic kidney disease

    Get PDF
    AIMS Arterial spin labelling (ASL) MRI measures perfusion without administration of contrast agent. While ASL has been validated in animals and healthy volunteers (HVs), application to chronic kidney disease (CKD) has been limited. We investigated the utility of ASL MRI in patients with CKD. METHODS We studied renal perfusion in 24 HVs and 17 patients with CKD (age 22-77 years, 40% male) using ASL MRI at 3.0T. Kidney function was determined using estimated glomerular filtration rate (eGFR). T1 relaxation time was measured using modified look-locker inversion and xFB02;ow-sensitive alternating inversion recovery true-fast imaging and steady precession was performed to measure cortical and whole kidney perfusion. RESULTS T1 was higher in CKD within cortex and whole kidney, and there was association between T1 time and eGFR. No association was seen between kidney size and volume and either T1, or ASL perfusion. Perfusion was lower in CKD in cortex (136 ± 37 vs. 279 ± 69 ml/min/100 g; p < 0.001) and whole kidney (146 ± 24 vs. 221 ± 38 ml/min/100 g; p < 0.001). There was significant, negative, association between T1 longitudinal relaxation time and ASL perfusion in both the cortex (r = -0.75, p < 0.001) and whole kidney (r = -0.50, p < 0.001). There was correlation between eGFR and both cortical (r = 0.73, p < 0.01) and whole kidney (r = 0.69, p < 0.01) perfusion. CONCLUSIONS Significant differences in renal structure and function were demonstrated using ASL MRI. T1 may be representative of structural changes associated with CKD; however, further investigation is required into the pathological correlates of reduced ASL perfusion and increased T1 time in CKD

    Rotation-induced 3D vorticity in 4He superfluid films adsorbed on a porous glass

    Full text link
    Detailed study of torsional oscillator experiments under steady rotation up to 6.28 rad/sec is reported for a 4He superfluid monolayer film formed in 1 micrometer-pore diameter porous glass. We found a new dissipation peak with the height being in proportion to the rotation speed, which is located to the lower temperature than the vortex pair unbinding peak observed in the static state. We propose that 3D coreless vortices ("pore vortices") appear under rotation to explain this new peak. That is, the new peak originates from dissipation close to the pore vortex lines, where large superfluid velocity shifts the vortex pair unbinding dissipation to lower temperature. This explanation is confirmed by observation of nonlinear effects at high oscillation amplitudes.Comment: 4pages, 5figure

    Characterizing correlations of flow oscillations at bottlenecks

    Full text link
    "Oscillations" occur in quite different kinds of many-particle-systems when two groups of particles with different directions of motion meet or intersect at a certain spot. We present a model of pedestrian motion that is able to reproduce oscillations with different characteristics. The Wald-Wolfowitz test and Gillis' correlated random walk are shown to hold observables that can be used to characterize different kinds of oscillations

    Kinetic energy of solid neon by Monte Carlo with improved Trotter- and finite-size extrapolation

    Full text link
    The kinetic energy of solid neon is calculated by a path-integral Monte Carlo approach with a refined Trotter- and finite-size extrapolation. These accurate data present significant quantum effects up to temperature T=20 K. They confirm previous simulations and are consistent with recent experiments.Comment: Text and figures revised for minor corrections (4 pages, 3 figures included by psfig

    A preliminary assessment of the effects of ATI-2042 in subjects with paroxysmal atrial fibrillation using implanted pacemaker methodology

    Get PDF
    Aims ATI-2042 (budiodarone) is a chemical analogue of amiodarone with a half life of 7 h. It is electrophysiologically similar to amiodarone, but may not have metabolic and interaction side effects. The sophisticated electrocardiograph logs of advanced DDDRP pacemakers were used to monitor the efficacy of ATI-2042. The aim of this study was to determine the preliminary efficacy and safety of ATI-2042 in patients with paroxsymal atrial fibrillation (PAF) and pacemakers. Methods and results Six women with AF burden (AFB) between 1 and 50% underwent six sequential 2-week study periods. Patients received 200 mg bid of ATI-2042 during Period 2 (p2), 400 mg bid during p3, 600 mg bid during p4, 800 mg bid during p5, and no drug during baseline and washout (p1 and p6). Pacemaker data for the primary outcome measure AFB were downloaded during each period. Mean AFB decreased between baseline and all doses: AFB at baseline (SD) was 20.3 ± 14.6% and mean AFB at 200 mg bid was 5.2 ± 4.2%, at 400 mg bid 5.2 ± 5.2%, at 600 mg bid 2.8 ± 3.4%, and at 800 mg bid 1.5 ± 0.5%. The mean reductions in AFB at all doses of ATI-2042 were statistically significant (P < 0.005). Atrial fibrillation burden increased in washout. Atrial fibrillation episodes tended to increase with ATI-2042, but this was offset by substantial decreases in episode duration. ATI-2042 was generally well tolerated. Conclusion ATI-2042 effectively reduced AFB over all doses studied by reducing mean episode duration. A large-scale study will be required to confirm this effect
    • …
    corecore