954 research outputs found

    On-orbit cryogenic fluid transfer

    Get PDF
    A number of future NASA and DOD missions have been identified that will require, or could benefit from resupply of cryogenic liquids in orbit. The most promising approach for accomplishing cryogenic fluid transfer in the weightlessness environment of space is to use the thermodynamic filling technique. This approach involves initially reducing the receiver tank temperature by using several charge hold vent cycles followed by filling the tank without venting. Martin Marietta Denver Aerospace, under contract to the NASA Lewis Research Center, is currently developing analytical models to describe the on orbit cryogenic fluid transfer process. A detailed design of a shuttle attached experimental facility, which will provide the data necessary to verify the analytical models, is also being performed

    HotSwap for bioinformatics: A STRAP tutorial

    Get PDF
    BACKGROUND: Bioinformatics applications are now routinely used to analyze large amounts of data. Application development often requires many cycles of optimization, compiling, and testing. Repeatedly loading large datasets can significantly slow down the development process. We have incorporated HotSwap functionality into the protein workbench STRAP, allowing developers to create plugins using the Java HotSwap technique. RESULTS: Users can load multiple protein sequences or structures into the main STRAP user interface, and simultaneously develop plugins using an editor of their choice such as Emacs. Saving changes to the Java file causes STRAP to recompile the plugin and automatically update its user interface without requiring recompilation of STRAP or reloading of protein data. This article presents a tutorial on how to develop HotSwap plugins. STRAP is available at and . CONCLUSION: HotSwap is a useful and time-saving technique for bioinformatics developers. HotSwap can be used to efficiently develop bioinformatics applications that require loading large amounts of data into memory

    Eg versus x relation from photoluminescence and electron microprobe investigations in p-type Hg1−xCdxTe (0.35 =< x =< 0.7)

    Get PDF
    Combined photoluminescence (at 10 T 300 K) and electron microprobe investigations have been carried out with HgCdTe samples grown from the melt or from solution. By exciting the samples through metallic masks with 200 μm diameter holes fixed with respect to the sample care was taken to pick-up both characteristic X-ray radiation as well as the photoluminescence from the same sample area. The Eg versus x relation determined in this way at T = 30 K has been compared with data from the interband absorption edge by other authors

    Horizontal travelling heater method growth of Hg1−xCdxTe with crucible rotation

    Get PDF
    A horizontal travelling heater method (THM) for growing cylindrical cyrstals from a partially filled solution zone has been investigated for the first time. By applying ampoule rotation, the whole cross section of the crystal is successively brought into contact with the liquid solution, which is effectively stirred by forced convection. This approach was used to grow single-crystalline Hg1−xCdxTe ingots from a Te-rich solution zone. The structural perfection and metallurgical homogeneity are equivalent to vertically-grown THM material

    Diagnosis of Fanconi Anemia: Mutation Analysis by Multiplex Ligation-Dependent Probe Amplification and PCR-Based Sanger Sequencing

    Get PDF
    Fanconi anemia (FA) is a rare inherited disease characterized by developmental defects, short stature, bone marrow failure, and a high risk of malignancies. FA is heterogeneous: 15 genetic subtypes have been distinguished so far. A clinical diagnosis of FA needs to be confirmed by testing cells for sensitivity to cross-linking agents in a chromosomal breakage test. As a second step, DNA testing can be employed to elucidate the genetic subtype of the patient and to identify the familial mutations. This knowledge allows preimplantation genetic diagnosis (PGD) and enables prenatal DNA testing in future pregnancies. Although simultaneous testing of all FA genes by next generation sequencing will be possible in the near future, this technique will not be available immediately for all laboratories. In addition, in populations with strong founder mutations, a limited test using Sanger sequencing and MLPA will be a cost-effective alternative. We describe a strategy and optimized conditions for the screening of FANCA, FANCB, FANCC, FANCE, FANCF, and FANCG and present the results obtained in a cohort of 54 patients referred to our diagnostic service since 2008. In addition, the follow up with respect to genetic counseling and carrier screening in the families is discussed

    Spin properties of dense near-surface ensembles of nitrogen-vacancy centres in diamond

    Get PDF
    We present a study of the spin properties of dense layers of near-surface nitrogen-vacancy (NV) centres in diamond created by nitrogen ion implantation. The optically detected magnetic resonance contrast and linewidth, spin coherence time, and spin relaxation time, are measured as a function of implantation energy, dose, annealing temperature and surface treatment. To track the presence of damage and surface-related spin defects, we perform in situ electron spin resonance spectroscopy through both double electron-electron resonance and cross-relaxation spectroscopy on the NV centres. We find that, for the energy (4304-30~keV) and dose (5×101110135\times10^{11}-10^{13}~ions/cm2^2) ranges considered, the NV spin properties are mainly governed by the dose via residual implantation-induced paramagnetic defects, but that the resulting magnetic sensitivity is essentially independent of both dose and energy. We then show that the magnetic sensitivity is significantly improved by high-temperature annealing at 1100\geq1100^\circC. Moreover, the spin properties are not significantly affected by oxygen annealing, apart from the spin relaxation time, which is dramatically decreased. Finally, the average NV depth is determined by nuclear magnetic resonance measurements, giving 10\approx10-17~nm at 4-6 keV implantation energy. This study sheds light on the optimal conditions to create dense layers of near-surface NV centres for high-sensitivity sensing and imaging applications.Comment: 12 pages, 7 figure

    A TQFT associated to the LMO invariant of three-dimensional manifolds

    Full text link
    We construct a Topological Quantum Field Theory (in the sense of Atiyah) associated to the universal finite-type invariant of 3-dimensional manifolds, as a functor from the category of 3-dimensional manifolds with parametrized boundary, satisfying some additional conditions, to an algebraic-combinatorial category. It is built together with its truncations with respect to a natural grading, and we prove that these TQFTs are non-degenerate and anomaly-free. The TQFT(s) induce(s) a (series of) representation(s) of a subgroup Lg{\cal L}_g of the Mapping Class Group that contains the Torelli group. The N=1 truncation produces a TQFT for the Casson-Walker-Lescop invariant.Comment: 28 pages, 13 postscript figures. Version 2 (Section 1 has been considerably shorten, and section 3 has been slightly shorten, since they will constitute a separate paper. Section 4, which contained only announce of results, has been suprimated; it will appear in detail elsewhere. Consequently some statements have been re-numbered. No mathematical changes have been made.

    Equivariant pretheories and invariants of torsors

    Full text link
    In the present paper we introduce and study the notion of an equivariant pretheory: basic examples include equivariant Chow groups, equivariant K-theory and equivariant algebraic cobordism. To extend this set of examples we define an equivariant (co)homology theory with coefficients in a Rost cycle module and provide a version of Merkurjev's (equivariant K-theory) spectral sequence for such a theory. As an application we generalize the theorem of Karpenko-Merkurjev on G-torsors and rational cycles; to every G-torsor E and a G-equivariant pretheory we associate a graded ring which serves as an invariant of E. In the case of Chow groups this ring encodes the information concerning the motivic J-invariant of E and in the case of Grothendieck's K_0 -- indexes of the respective Tits algebras.Comment: 23 pages; this is an essentially extended version of the previous preprint: the construction of an equivariant cycle (co)homology and the spectral sequence (generalizing the long exact localization sequence) are adde

    Superfluid Helium Tanker (SFHT) study

    Get PDF
    Replenishment of superfluid helium (SFHe) offers the potential of extending the on-orbit life of observatories, satellite instruments, sensors and laboratories which operate in the 2 K temperature regime. A reference set of resupply customers was identified as representing realistic helium servicing requirements and interfaces for the first 10 years of superfluid helium tanker (SFHT) operations. These included the Space Infrared Telescope Facility (SIRTF), the Advanced X-ray Astrophysics Facility (AXAF), the Particle Astrophysics Magnet Facility (Astromag), and the Microgravity and Materials Processing Sciences Facility (MMPS)/Critical Point Phenomena Facility (CPPF). A mixed-fleet approach to SFHT utilization was considered. The tanker permits servicing from the Shuttle cargo bay, in situ when attached to the OMV and carried to the user spacecraft, and as a depot at the Space Station. A SFHT Dewar ground servicing concept was developed which uses a dedicated ground cooling heat exchanger to convert all the liquid, after initial fill as normal fluid, to superfluid for launch. This concept permits the tanker to be filled to a near full condition, and then cooled without any loss of fluid. The final load condition can be saturated superfluid with any desired ullage volume, or the tank can be totally filed and pressurized. The SFHT Dewar and helium plumbing system design has sufficient component redundancy to meet fail-operational, fail-safe requirements, and is designed structurally to meet a 50 mission life usage requirement. Technology development recommendations were made for the selected SFHT concept, and a Program Plan and cost estimate prepared for a phase C/D program spanning 72 months from initiation through first launch in 1997

    Change in acetabular version after lumbar pedicle subtraction osteotomy to correct post-operative flat back: EOS® measurements of 38 acetabula

    Get PDF
    AbstractBackgroundAbnormalities in acetabular orientation can promote the development of hip osteoarthritis, femoro-acetabular impingement, or even acetabular cup malposition. The objective of the present study was to determine whether pedicle substraction osteotomy (PSO) to correct sagittal spinal imbalance affected acetabular orientation.HypothesisPSO performed to correct sagittal spinal imbalance affects acetabular orientation by changing the pelvic parameters.Materials and methodsThis was a descriptive study in which two observers measured the acetabular parameters on both sides in 19 patients (38 acetabula) before and after PSO for post-operative flat-back syndrome. Mean time from PSO to post-operative measurements was 19months. Measurements were taken twice at a 2-week interval, on standing images obtained using the EOS® imaging system and sterEOS® software to obtain 3D reconstructions of synchronised 2D images. Acetabular anteversion and inclination were measured relative to the vertical plane. Mean pre-PSO and post-PSO values were compared using the paired t-test, and P values lower than 0.05 were considered significant. To assess inter-observer and intra-observer reproducibility, we computed the intra-class correlation coefficients (ICCs).ResultsThe measurements showed significant acetabular retroversion after PSO, of 7.6° on the right and 6.5° on the left (P<0.001). Acetabular inclination diminished significantly, by 4.5° on the right and 2.5° on the left (P<0.01). Inclination of the anterior pelvic plane decreased by 8.4° (P<0.01). Pelvic incidence was unchanged, whereas sacral slope increased by 10.5° (P<0.001) and pelvic tilt decreased by 10.9° (P<0.001). The ICC was 0.98 for both inter-observer and intra-observer reproducibility.ConclusionChanging the sagittal spinal alignment modifies both the pelvic and the acetabular parameters. PSO significantly increases sacral slope, thus inducing anterior pelvic tilt with significant acetabular retroversion. The measurements obtained using sterEOS® showed good inter-observer and intra-observer reproducibility. To our knowledge, this is the first study of changes in acetabular version after PSO
    corecore