121 research outputs found

    Endovascular Abdominal Aortic Aneurysm Repair With Ovation Alto Stent Graft: Protocol for the ALTAIR (ALTo endogrAft Italian Registry) Study

    Get PDF
    Background: Since 2010, the Ovation Abdominal Stent Graft System has offered an innovative sealing option for abdominal aortic aneurysm (AAA) by including a sealing ring filled with polymer 13 mm from the renal arteries. In August 2020, the redesigned Ovation Alto, with a sealing ring 6 mm closer to the top of the fabric, received CE Mark approval. Objective: This registry study aims to evaluate intraoperative, perioperative, and postoperative results in patients treated by the Alto stent graft (Endologix Inc.) for elective AAA repair in a multicentric consecutive experience. Methods: All consecutive eligible patients submitted to endovascular aneurysm repair (EVAR) by Alto Endovascular AAA implantation will be included in this analysis. Patients will be submitted to EVAR procedures based on their own preferences, anatomical features, and operators experience. An estimated number of 300 patients submitted to EVAR with Alto stent graft should be enrolled. It is estimated that the inclusion period will be 24 months. The follow-up period is set to be 5 years. Full data sets and cross-sectional images of contrast-enhanced computed tomography scan performed before EVAR, at the first postoperative month, at 24 or 36 months, and at 5-year follow-up interval will be reported in the central database for a centralized core laboratory review of morphological changes. The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with the Alto stent graft in short- (90-day), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will be also addressed: operative time; intraoperative radiation exposure; contrast medium usage; AAA sac shrinkage at 12-month and 5-year follow-up; any potential role of patients' baseline characteristics, valuated on preoperative computed tomography angiographic study, and of device configuration (number of component) in the primary endpoint. Results: The study is currently in the recruitment phase and the final patient is expected to be treated by the end of 2023 and then followed up for 5 years. A total of 300 patients will be recruited. Analyses will focus on primary and secondary endpoints. Updated results will be shared at 1- and 3-5-year follow-ups. Conclusions: The results from this registry study could validate the safety and effectiveness of the new design of the Ovation Alto Stent Graft. The technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on-label

    Restenosis after Coronary and Peripheral Intervention: Efficacy and Clinical Impact of Cilostazol

    Get PDF
    Restenosis is one of the main complications in patients undergoing coronary or peripheral revascularization procedures and is the leading cause for their long-term failures. Cilostazol is the only pharmacotherapy that showed an adequate efficacy for preventing restenosis in randomized, controlled studies after coronary or peripheral revascularization procedures. The present review sums up the main clinical evidence supporting the use of cilostazol after revascularization interventions, focusing on all its benefits, warnings, and administration schedules

    Acute deep vein thrombosis and pulmonary embolism: is the thromboaspiration device an appropriate choice?

    Get PDF
    Nowadays patients affected by deep vein thrombosis (DVT) and pulmonary embolism (PE) are studied widely but the challenge for physicians is when and how they are to be treated. Most patients present serious comorbidities that can potentially make treatment difficult. An increasing cohort of patients cannot be treated with systemic fibrinolysis but fortunately today, physicians can utilize a number of different instruments to resolve acute DVT and PE

    Midterm results of proximal aneurysm sealing with the ovation stent-graft according to On-vs off-label use

    Get PDF
    Purpose: To compare the use of the Ovation stent-graft according to the â\u89¥7-mm neck length specified by the original instructions for use (IFU) vs those treated off-label (OL) for necks 2 mm). Results: At 3 years, there was no aneurysm-related death, rupture, stent-graft migration, or neck enlargement. There were no differences in terms of freedom from type Ia endoleak (98.2% IFU vs 96.8% OL, p=0.6; hazard ratio [HR] 0.55, 95% CI 0.02 to 9.71 or freedom from any device-related reintervention (92.8% IFU vs 96.4% OL, p=0.4; HR 2.42, 95% CI 0.34 to 12.99). In the sealing zone, the mean change in diameters was-0.05±0.8 mm in the IFU group and -0.1±0.5 mm in the OL group. Conclusion: Use of the Ovation stent-graft in patients with neck length <7 mm achieved midterm outcomes similar to patients with â\u89¥7-mm-long necks. These midterm data show that the use of the Ovation system for the treatment of infrarenal abdominal aortic aneurysm is not restricted by the conventional measurement of aortic neck length, affirming the recent Food and Drug Administration-approved changes to the IFU

    Focusing on diabetic ulcers

    Get PDF
    Foot ulcers associated with Diabetes mellitus require immediate attention due to risk of amputation if left untreated. Herein we focus on the mitigating risk factors and physiopathology of the diabetic foot, recounting our own surgical approach and revascularization procedures

    Impact on outcome of different types of carotid stent: Results from the European Registry of Carotid Artery Stenting

    Get PDF
    AIMS: Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). METHODS AND RESULTS: The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). CONCLUSIONS: Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk

    ZILVERPASS Study: ZILVER PTX Stent versus Prosthetic Above-the-Knee Bypass Surgery in Femoropopliteal Lesions, 5-year Results.

    Get PDF
    PURPOSE To report the 60-month safety and effectiveness results of a multicenter, prospective, randomized controlled trial comparing the ZILVER PTX paclitaxel-eluting stent to prosthetic above-the-knee bypass for the treatment of symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions. MATERIALS AND METHODS Patients were enrolled between October 2013 and July 2017. One of the secondary outcomes was primary patency at 60 months, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex ultrasound peak systolic velocity ratio < 2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass at 60 months. Survival rates after 5 years were also analyzed. RESULTS 220 patients (mean age 68.6 ± 10.5 years; 159 men) were included and randomized to ZILVER PTX (n = 113, 51.40%) or BYPASS group (n = 107, 48.60%). The 60-month primary patency rate was 49.3% for the ZILVER PTX group versus 40.7% for the bypass group (p = 0.6915). Freedom from TLR was 63.8% for the ZILVER PTX group versus 52.8% for the bypass group (p = 0.2637). At 5 years, no significant difference in survival rate could be seen between the ZILVER PTX and the bypass group (69.1% vs. 71% respectively, p = 0.5503). CONCLUSION Even at 5 years, non-inferior safety and effectiveness results of the ZILVER PTX could be seen. These findings confirmed that the use of ZILVER PTX stents can be considered as a valid alternative for bypass surgery when treating long and complex femoropopliteal lesions
    • …
    corecore