9 research outputs found
Effect of 15-deoxyspergualin on experimental organ transplantation
DSPG had a definite but relatively feeble immunosuppressive effect in rats undergoing heterotopic heart transplantation and in dogs after renal transplantation. The drug was toxic in both species, although less so in rats. In dogs, synergistic interactions with cyclosporine and steroids were not evident
Canine kidney transplantation with FK-506 alone or in combination with cyclosporine and steroids.
The immunosuppressive agent FK permitted increased kidney transplant survival in dogs over a wide dose range, but with weight loss and manifold evidence of toxicity. The best use of FK at low doses was in combination with CyA and Pred
Deep Learning Algorithms for the Detection of Suspicious Pigmented Skin Lesions in Primary Care Settings: A Systematic Review and Meta- Analysis
Early detection of suspicious pigmented skin lesions is crucial for improving the outcomes and survival rates of skin cancers. However, the accuracy of clinical diagnosis by primary care physicians (PCPs) is suboptimal, leading to unnecessary referrals and biopsies. In recent years, deep learning (DL) algorithms have shown promising results in the automated detection and classification of skin lesions. This systematic review and meta-analysis aimed to evaluate the diagnostic performance of DL algorithms for the detection of suspicious pigmented skin lesions in primary care settings. A comprehensive literature search was conducted using electronic databases, including PubMed, Scopus, IEEE Xplore, Cochrane Central Register of Controlled Trials (CENTRAL), and Web of Science. Data from eligible studies were extracted, including study characteristics, sample size, algorithm type, sensitivity, specificity, diagnostic odds ratio (DOR), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and receiver operating characteristic curve analysis. Three studies were included. The results showed that DL algorithms had a high sensitivity (90%, 95% CI: 90-91%) and specificity (85%, 95% CI: 84-86%) for detecting suspicious pigmented skin lesions in primary care settings. Significant heterogeneity was observed in both sensitivity (p = 0.0062, I² = 80.3%) and specificity (p < 0.001, I² = 98.8%). The analysis of DOR and PLR further demonstrated the strong diagnostic performance of DL algorithms. The DOR was 26.39, indicating a strong overall diagnostic performance of DL algorithms. The PLR was 4.30, highlighting the ability of these algorithms to influence diagnostic outcomes positively. The NLR was 0.16, indicating that a negative test result decreased the odds of misdiagnosis. The area under the curve of DL algorithms was 0.95, indicating excellent discriminative ability in distinguishing between benign and malignant pigmented skin lesions. DL algorithms have the potential to significantly improve the detection of suspicious pigmented skin lesions in primary care settings. Our analysis showed that DL exhibited promising performance in the early detection of suspicious pigmented skin lesions. However, further studies are needed