40 research outputs found

    Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind

    Get PDF
    PurposeRetinitis pigmentosa (RP) is a group of inherited retinal degenerations leading to blindness due to photoreceptor loss. Retinitis pigmentosa is a rare disease, affecting only approximately 100 000 people in the United States. There is no cure and no approved medical therapy to slow or reverse RP. The purpose of this clinical trial was to evaluate the safety, reliability, and benefit of the Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) in restoring some visual function to subjects completely blind from RP. We report clinical trial results at 1 and 3 years after implantation.DesignThe study is a multicenter, single-arm, prospective clinical trial.ParticipantsThere were 30 subjects in 10 centers in the United States and Europe. Subjects served as their own controls, that is, implanted eye versus fellow eye, and system on versus system off (native residual vision).MethodsThe Argus II System was implanted on and in a single eye (typically the worse-seeing eye) of blind subjects. Subjects wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina.Main Outcome MeasuresThe primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests.ResultsA total of 29 of 30 subjects had functioning Argus II Systems implants 3 years after implantation. Eleven subjects experienced a total of 23 serious device- or surgery-related adverse events. All were treated with standard ophthalmic care. As a group, subjects performed significantly better with the system on than off on all visual function tests and functional vision assessments.ConclusionsThe 3-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. Earlier results from this trial were used to gain approval of the Argus II by the Food and Drug Administration and a CE mark in Europe. The Argus II System is the first and only retinal implant to have both approvals

    Worldwide Argus II implantation: recommendations to optimize patient outcomes

    Get PDF
    Abstract Background A position paper based on the collective experiences of Argus II Retinal Prosthesis System investigators to review strategies to optimize outcomes in patients with retinitis pigmentosa undergoing retinal prosthesis implantation. Methods Retinal surgeons, device programmers, and rehabilitation specialists from Europe, Canada, Middle East, and the United States were convened to the first international Argus II Investigator Meeting held in Ann Arbor, MI in March 2015. The recommendations from the collective experiences were collected. Factors associated with successful outcomes were determined. Results Factors leading to successful outcomes begin with appropriate patient selection, expectation counseling, and preoperative retinal assessment. Challenges to surgical implantation include presence of staphyloma and inadequate Tenon’s capsule or conjunctiva. Modified surgical technique may reduce risks of complications such as hypotony and conjunctival erosion. Rehabilitation efforts and correlation with validated outcome measures following implantation are critical. Conclusions Bringing together Argus II investigators allowed the identification of strategies to optimize patient outcomes. Establishing an on-line collaborative network will foster coordinated research efforts to advance outcome assessment and rehabilitation strategies.http://deepblue.lib.umich.edu/bitstream/2027.42/134581/1/12886_2016_Article_225.pd

    Effects and feasibility of a standardised orientation and mobility training in using an identification cane for older adults with low vision: design of a randomised controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Orientation and mobility training (O&M-training) in using an identification cane, also called symbol cane, is provided to people with low vision to facilitate independent participation in the community. In The Netherlands this training is mainly practice-based because a standardised and validly evaluated O&M-training in using the identification cane is lacking. Recently a standardised O&M-training in using the identification cane was developed. This training consists of two face-to-face sessions and one telephone session during which, in addition to usual care, the client's needs regarding mobility are prioritised, and cognitive restructuring techniques, action planning and contracting are applied to facilitate the use of the cane. This paper presents the design of a randomised controlled trial aimed to evaluate this standardised O&M-training in using the identification cane in older adults with low vision.</p> <p>Methods/design</p> <p>A parallel group randomised controlled trial was designed to compare the standardised O&M-training with usual care, i.e. the O&M-training commonly provided by the mobility trainer. Community-dwelling older people who ask for support at a rehabilitation centre for people with visual impairment and who are likely to receive an O&M-training in using the identification cane are included in the trial (N = 190). The primary outcomes of the effect evaluation are ADL self care and visual functioning with respect to distance activities and mobility. Secondary outcomes include quality of life, feelings of anxiety, symptoms of depression, fear of falling, and falls history. Data for the effect evaluation are collected by means of telephone interviews at baseline, and at 5 and 17 weeks after the start of the O&M-training. In addition to an effect evaluation, a process evaluation to study the feasibility of the O&M-training is carried out.</p> <p>Discussion</p> <p>The screening procedure for eligible participants started in November 2007 and will continue until October 2009. Preliminary findings regarding the evaluation are expected in the course of 2010. If the standardised O&M-training is more effective than the current O&M-training or, in case of equal effectiveness, is considered more feasible, the training will be embedded in the Dutch national instruction for mobility trainers.</p> <p>Trial registration</p> <p>ClinicalTrials.gov NCT00946062</p

    Update on the Development of a Prosthetic Low Vision Rehabilitation (PLoVR) curriculum

    No full text

    Analysis of Case Reports for the Argus II Retinal Implant

    No full text

    Towards a unified set of performance outcomes for vision restoration trials

    No full text

    Developing a calibrated ultra-low vision (ULV) assessment toolkit

    No full text

    Elaborating a Rehabilitation Curriculum for Argus® II Retinal Prosthesis System Users

    No full text
    corecore