64 research outputs found

    Tibiofemoral Contact Forces in the Anterior Cruciate Ligament-Reconstructed Knee.

    Get PDF
    PURPOSE: To investigate differences in ACL reconstructed (ACLR) and healthy individuals in terms of the magnitude of the tibiofemoral contact forces, as well as the relative muscle and external load contributions to those contact forces, during walking, running and sidestepping gait tasks. METHODS: A computational electromyography-driven neuromusculoskeletal model was used to estimate the muscle and tibiofemoral contact forces in those with combined semitendinosus and gracilis tendon autograft ACLR (n=104, 29.7±6.5 years, 78.1±14.4 kg) and healthy controls (n=60, 27.5±5.4 years, 67.8±14.0 kg) during walking (1.4±0.2 ms), running (4.5±0.5 ms) and sidestepping (3.7±0.6 ms). Within the computational model, the semitendinosus of ACLR participants was adjusted to account for literature reported strength deficits and morphological changes subsequent to autograft harvesting. RESULTS: ACLRs had smaller maximum total and medial tibiofemoral contact forces (~80% of control values, scaled to bodyweight) during the different gait tasks. Compared to controls, ACLRs were found to have a smaller maximum knee flexion moment, which explained the smaller tibiofemoral contact forces. Similarly, compared to controls, ACLRs had both a smaller maximum knee flexion angle and knee flexion excursion during running and sidestepping, which may have concentrated the articular contact forces to smaller areas within the tibiofemoral joint. Mean relative muscle and external load contributions to the tibiofemoral contact forces were not significantly different between ACLRs and controls. CONCLUSION: ACLRs had lower bodyweight-scaled tibiofemoral contact forces during walking, running and sidestepping, likely due to lower knee flexion moments and straighter knee during the different gait tasks. The relative contributions of muscles and external loads to the contact forces were equivalent between groups

    Tibiofemoral contact forces during walking, running and sidestepping

    Get PDF
    We explored the tibiofemoral contact forces and the relative contributions of muscles and external loads to those contact forces during various gait tasks. Second, we assessed the relationships between external gait measures and contact forces. A calibrated electromyography-driven neuromusculoskeletal model estimated the tibiofemoral contact forces during walking (1.44 ± 0.22 m s−1), running (4.38 ± 0.42 m s−1) and sidestepping (3.58 ± 0.50 m s−1) in healthy adults (n = 60, 27.3 ± 5.4 years, 1.75 ± 0.11 m, and 69.8 ± 14.0 kg). Contact forces increased from walking (∼1–2.8 BW) to running (∼3–8 BW), sidestepping had largest maximum total (8.47 ± 1.57 BW) and lateral contact forces (4.3 ± 1.05 BW), while running had largest maximum medial contact forces (5.1 ± 0.95 BW). Relative muscle contributions increased across gait tasks (up to 80–90% of medial contact forces), and peaked during running for lateral contact forces (∼90%). Knee adduction moment (KAM) had weak relationships with tibiofemoral contact forces (all R2 < 0.36) and the relationships were gait task-specific. Step-wise regression of multiple external gait measures strengthened relationships (0.20 < Radj2 < 0.78), but were variable across gait tasks. Step-wise regression equations from a particular gait task (e.g. walking) produced large errors when applied to a different gait task (e.g. running or sidestepping). Muscles well stabilized the knee, increasing their role in stabilization from walking to running to sidestepping. KAM was a poor predictor of medial contact force and load distributions. Step-wise regression models results suggest the relationships between external gait measures and contact forces cannot be generalized across tasks. Neuromusculoskeletal modelling may be required to examine tibiofemoral contact forces and role of muscle in knee stabilization across gait tasks

    Resonant scattering of spin waves from a region of inhomogeneous magnetic field in a ferromagnetic film

    Full text link
    The transmission of a dipole-dominated spin wave in a ferromagnetic film through a localised inhomogeneity in the form of a magnetic field produced by a dc current through a wire placed on the film surface was studied experimentally and theoretically. It was shown that the amplitude and phase of the transmitted wave can be simultaneously affected by the current induced field, a feature that will be relevant for logic based on spin wave transport. The direction of the current creates either a barrier or well for spin wave transmission. The main observation is that the current dependence of the amplitude of the spin wave transmitted through the well inhomogeneity is non-monotonic. The dependence has a minimum and an additional maximum. A theory was constructed to clarify the nature of the maximum. It shows that the transmission of spin waves through the inhomogeneity can be considered as a scattering process and that the additional maximum is a scattering resonance

    Mortality from gastrointestinal congenital anomalies at 264 hospitals in 74 low-income, middle-income, and high-income countries: a multicentre, international, prospective cohort study

    Get PDF
    Background: Congenital anomalies are the fifth leading cause of mortality in children younger than 5 years globally. Many gastrointestinal congenital anomalies are fatal without timely access to neonatal surgical care, but few studies have been done on these conditions in low-income and middle-income countries (LMICs). We compared outcomes of the seven most common gastrointestinal congenital anomalies in low-income, middle-income, and high-income countries globally, and identified factors associated with mortality. // Methods: We did a multicentre, international prospective cohort study of patients younger than 16 years, presenting to hospital for the first time with oesophageal atresia, congenital diaphragmatic hernia, intestinal atresia, gastroschisis, exomphalos, anorectal malformation, and Hirschsprung's disease. Recruitment was of consecutive patients for a minimum of 1 month between October, 2018, and April, 2019. We collected data on patient demographics, clinical status, interventions, and outcomes using the REDCap platform. Patients were followed up for 30 days after primary intervention, or 30 days after admission if they did not receive an intervention. The primary outcome was all-cause, in-hospital mortality for all conditions combined and each condition individually, stratified by country income status. We did a complete case analysis. // Findings: We included 3849 patients with 3975 study conditions (560 with oesophageal atresia, 448 with congenital diaphragmatic hernia, 681 with intestinal atresia, 453 with gastroschisis, 325 with exomphalos, 991 with anorectal malformation, and 517 with Hirschsprung's disease) from 264 hospitals (89 in high-income countries, 166 in middle-income countries, and nine in low-income countries) in 74 countries. Of the 3849 patients, 2231 (58·0%) were male. Median gestational age at birth was 38 weeks (IQR 36–39) and median bodyweight at presentation was 2·8 kg (2·3–3·3). Mortality among all patients was 37 (39·8%) of 93 in low-income countries, 583 (20·4%) of 2860 in middle-income countries, and 50 (5·6%) of 896 in high-income countries (p<0·0001 between all country income groups). Gastroschisis had the greatest difference in mortality between country income strata (nine [90·0%] of ten in low-income countries, 97 [31·9%] of 304 in middle-income countries, and two [1·4%] of 139 in high-income countries; p≤0·0001 between all country income groups). Factors significantly associated with higher mortality for all patients combined included country income status (low-income vs high-income countries, risk ratio 2·78 [95% CI 1·88–4·11], p<0·0001; middle-income vs high-income countries, 2·11 [1·59–2·79], p<0·0001), sepsis at presentation (1·20 [1·04–1·40], p=0·016), higher American Society of Anesthesiologists (ASA) score at primary intervention (ASA 4–5 vs ASA 1–2, 1·82 [1·40–2·35], p<0·0001; ASA 3 vs ASA 1–2, 1·58, [1·30–1·92], p<0·0001]), surgical safety checklist not used (1·39 [1·02–1·90], p=0·035), and ventilation or parenteral nutrition unavailable when needed (ventilation 1·96, [1·41–2·71], p=0·0001; parenteral nutrition 1·35, [1·05–1·74], p=0·018). Administration of parenteral nutrition (0·61, [0·47–0·79], p=0·0002) and use of a peripherally inserted central catheter (0·65 [0·50–0·86], p=0·0024) or percutaneous central line (0·69 [0·48–1·00], p=0·049) were associated with lower mortality. // Interpretation: Unacceptable differences in mortality exist for gastrointestinal congenital anomalies between low-income, middle-income, and high-income countries. Improving access to quality neonatal surgical care in LMICs will be vital to achieve Sustainable Development Goal 3.2 of ending preventable deaths in neonates and children younger than 5 years by 2030

    Mortality from gastrointestinal congenital anomalies at 264 hospitals in 74 low-income, middle-income, and high-income countries: a multicentre, international, prospective cohort study

    Get PDF
    Summary Background Congenital anomalies are the fifth leading cause of mortality in children younger than 5 years globally. Many gastrointestinal congenital anomalies are fatal without timely access to neonatal surgical care, but few studies have been done on these conditions in low-income and middle-income countries (LMICs). We compared outcomes of the seven most common gastrointestinal congenital anomalies in low-income, middle-income, and high-income countries globally, and identified factors associated with mortality. Methods We did a multicentre, international prospective cohort study of patients younger than 16 years, presenting to hospital for the first time with oesophageal atresia, congenital diaphragmatic hernia, intestinal atresia, gastroschisis, exomphalos, anorectal malformation, and Hirschsprung’s disease. Recruitment was of consecutive patients for a minimum of 1 month between October, 2018, and April, 2019. We collected data on patient demographics, clinical status, interventions, and outcomes using the REDCap platform. Patients were followed up for 30 days after primary intervention, or 30 days after admission if they did not receive an intervention. The primary outcome was all-cause, in-hospital mortality for all conditions combined and each condition individually, stratified by country income status. We did a complete case analysis. Findings We included 3849 patients with 3975 study conditions (560 with oesophageal atresia, 448 with congenital diaphragmatic hernia, 681 with intestinal atresia, 453 with gastroschisis, 325 with exomphalos, 991 with anorectal malformation, and 517 with Hirschsprung’s disease) from 264 hospitals (89 in high-income countries, 166 in middleincome countries, and nine in low-income countries) in 74 countries. Of the 3849 patients, 2231 (58·0%) were male. Median gestational age at birth was 38 weeks (IQR 36–39) and median bodyweight at presentation was 2·8 kg (2·3–3·3). Mortality among all patients was 37 (39·8%) of 93 in low-income countries, 583 (20·4%) of 2860 in middle-income countries, and 50 (5·6%) of 896 in high-income countries (p<0·0001 between all country income groups). Gastroschisis had the greatest difference in mortality between country income strata (nine [90·0%] of ten in lowincome countries, 97 [31·9%] of 304 in middle-income countries, and two [1·4%] of 139 in high-income countries; p≤0·0001 between all country income groups). Factors significantly associated with higher mortality for all patients combined included country income status (low-income vs high-income countries, risk ratio 2·78 [95% CI 1·88–4·11], p<0·0001; middle-income vs high-income countries, 2·11 [1·59–2·79], p<0·0001), sepsis at presentation (1·20 [1·04–1·40], p=0·016), higher American Society of Anesthesiologists (ASA) score at primary intervention (ASA 4–5 vs ASA 1–2, 1·82 [1·40–2·35], p<0·0001; ASA 3 vs ASA 1–2, 1·58, [1·30–1·92], p<0·0001]), surgical safety checklist not used (1·39 [1·02–1·90], p=0·035), and ventilation or parenteral nutrition unavailable when needed (ventilation 1·96, [1·41–2·71], p=0·0001; parenteral nutrition 1·35, [1·05–1·74], p=0·018). Administration of parenteral nutrition (0·61, [0·47–0·79], p=0·0002) and use of a peripherally inserted central catheter (0·65 [0·50–0·86], p=0·0024) or percutaneous central line (0·69 [0·48–1·00], p=0·049) were associated with lower mortality. Interpretation Unacceptable differences in mortality exist for gastrointestinal congenital anomalies between lowincome, middle-income, and high-income countries. Improving access to quality neonatal surgical care in LMICs will be vital to achieve Sustainable Development Goal 3.2 of ending preventable deaths in neonates and children younger than 5 years by 2030

    Nouvel ergomètre de terrain pour mesurer de manière reproductible la force maximale et le taux de développement de la force des ischio-jambiers

    No full text
    International audienceObjectives. — Hamstring strain injuries are common in sprint-based activities and multifacto- rial. One of the main risk factors is the deficit of hamstring eccentric strength, which is not easily assessed in field conditions. Therefore, a new ergometer named ‘‘Hamtech’’ has been developed to accurately and practically assess hamstring force output. The aim of this study was to test the reproducibility of this novel ergometer during maximal isometric and eccentric contractions.Materials and methods. — Thirteen soccer players (age: 20.7 ± 1.6 years; stature: 178.1±4.9cm; body mass: 72.1±6.3kg) were recruited. After two familiarization ses- sions, hamstring force production was recorded during maximal isometric and eccentric contractions using the Hamtech. The coefficients of variations and intra-class correlations coefficients were used to quantify reproducibility.Results. — This ergometer allows reproducible measurements of unilateral (isomet- ric+eccentric) and bilateral (eccentric) peak force. However, the reproducibility was moderate to good (unilateral) and poor (bilateral) for the knee angle at the eccentric peak force. A good reproducibility was observed for the rate of force development at 200-ms during maximal isometric contractions. The Hamtech offers a simple and reproducible solution to measure hamstring force production during isometric and eccentric contractions. The use of unilateral hamstring muscles at long muscular length might provide a valuable alternative to the classical bilateral condition to assess the hamstring force production.Objectifs : Les blessures aux ischio-jambiers sont fréquentes dans les activités basées sur le sprint et sont multifactorielles. L'un des principaux facteurs de risque est le déficit de force excentrique des ischio-jambiers, qui n'est pas facile à évaluer sur le terrain. Par conséquent, un nouvel ergomètre appelé "Hamtech" a été développé pour évaluer de manière précise et pratique, la force des ischio-jambiers. L'objectif de cette étude était de tester la reproductibilité de ce nouvel ergomètre lors de contractions isométriques et excentriques maximales

    Greater magnitude tibiofemoral contact forces are associated with reduced prevalence of osteochondral pathologies 2-3 years following anterior cruciate ligament reconstruction

    Get PDF
    PURPOSE: External loading of osteoarthritic and healthy knees correlates with current and future osteochondral tissue state. These relationships have not been examined following anterior cruciate ligament reconstruction. We hypothesised greater magnitude tibiofemoral contact forces were related to increased prevalence of osteochondral pathologies, and these relationships were exacerbated by concomitant meniscal injury. METHODS: This was a cross-sectional study of 100 individuals (29.7 ± 6.5 years, 78.1 ± 14.4 kg) examined 2-3 years following hamstring tendon anterior cruciate ligament reconstruction. Thirty-eight participants had concurrent meniscal pathology (30.6 ± 6.6 years, 83.3 ± 14.3 kg), which included treated and untreated meniscal injury, and 62 participants (29.8 ± 6.4 years, 74.9 ± 13.3 kg) were free of meniscal pathology. Magnetic resonance imaging of reconstructed knees was used to assess prevalence of tibiofemoral osteochondral pathologies (i.e., cartilage defects and bone marrow lesions). A calibrated electromyogram-driven neuromusculoskeletal model was used to predict medial and lateral tibiofemoral compartment contact forces from gait analysis data. Relationships between contact forces and osteochondral pathology prevalence were assessed using logistic regression models. RESULTS: In patients with reconstructed knees free from meniscal pathology, greater medial contact forces were related to reduced prevalence of medial cartilage defects (odds ratio (OR) = 0.7, Wald χ2(2) = 7.9, 95% confidence interval (CI) = 0.50-95, p = 0.02) and medial bone marrow lesions (OR = 0.8, Wald χ2(2) = 4.2, 95% CI = 0.7-0.99, p = 0.04). No significant relationships were found in lateral compartments. In reconstructed knees with concurrent meniscal pathology, no relationships were found between contact forces and osteochondral pathologies. CONCLUSIONS: In patients with reconstructed knees free from meniscal pathology, increased contact forces were associated with fewer cartilage defects and bone marrow lesions in medial, but not, lateral tibiofemoral compartments. No significant relationships were found between contact forces and osteochondral pathologies in reconstructed knees with meniscal pathology for any tibiofemoral compartment. Future studies should focus on determining longitudinal effects of contact forces and changes in osteochondral pathologies. LEVEL OF EVIDENCE: IV

    Features of information erasing from multidisc HDDs by pulse magnetic field

    No full text
    This work presents the research results of information erasing from modern multidisc HDDs by pulse magnetic fields. The quality of information erasing was assessed by methods of atomic force microscopy. The island character of information erasing is explained by shielding of magnetic impulse by metal elements of HDD design. Amplitude and time characteristics of magnetic pulses needed for reliable information erasing from modern multidisc HDDs are defined

    SYNTHESIS AND USE OF (E)-1-ETHOXY-3-FLUOROALKYL-3-HYDROXY-4-(-4-METHYLPHENYLSULFINYL)BUT-1-ENES

    No full text
    Condensation of the lithium salt of (R)-methyl p-tolyl sulfoxide 1 with fluorinated N,P-unsaturated ketones 2 leads to (3 R/S,R,)-(E)- 1- ethoxy-3-fluoroalkyl-3-hydroxy-4-(4-methylphenylsulfinyl)b1u- te-n es 3, whose absolute stereochemistry was determined by X-ray diffraction and NMR analyses. Reductive removal of the sulfinyl chiral auxiliary allows the preparation of both enantiomers of fluorinated tertiary alcohols of type 8 and 9
    • …
    corecore