59 research outputs found

    Five-year review of an international clinical research-training program

    Get PDF
    The exponential increase in clinical research has profoundly changed medical sciences. Evidence that has accumulated in the past three decades from clinical trials has led to the proposal that clinical care should not be based solely on clinical expertise and patient values, and should integrate robust data from systematic research. As a consequence, clinical research has become more complex and methods have become more rigorous, and evidence is usually not easily translated into clinical practice. Therefore, the instruction of clinical research methods for scientists and clinicians must adapt to this new reality. To address this challenge, a global distance-learning clinical research-training program was developed, based on collaborative learning, the pedagogical goal of which was to develop critical thinking skills in clinical research. We describe and analyze the challenges and possible solutions of this course after 5 years of experience (2008-2012) with this program. Through evaluation by students and faculty, we identified and reviewed the following challenges of our program: 1) student engagement and motivation, 2) impact of heterogeneous audience on learning, 3) learning in large groups, 4) enhancing group learning, 5) enhancing social presence, 6) dropouts, 7) quality control, and 8) course management. We discuss these issues and potential alternatives with regard to our research and background

    Five-year review of an international clinical research-training program

    Get PDF
    The exponential increase in clinical research has profoundly changed medical sciences. Evidence that has accumulated in the past three decades from clinical trials has led to the proposal that clinical care should not be based solely on clinical expertise and patient values, and should integrate robust data from systematic research. As a consequence, clinical research has become more complex and methods have become more rigorous, and evidence is usually not easily translated into clinical practice. Therefore, the instruction of clinical research methods for scientists and clinicians must adapt to this new reality. To address this challenge, a global distance-learning clinical research-training program was developed, based on collaborative learning, the pedagogical goal of which was to develop critical thinking skills in clinical research. We describe and analyze the challenges and possible solutions of this course after 5 years of experience (2008-2012) with this program. Through evaluation by students and faculty, we identified and reviewed the following challenges of our program: 1) student engagement and motivation, 2) impact of heterogeneous audience on learning, 3) learning in large groups, 4) enhancing group learning, 5) enhancing social presence, 6) dropouts, 7) quality control, and 8) course management. We discuss these issues and potential alternatives with regard to our research and background

    Rapid Tooling Method for Soft Customized Removable Oral Appliances

    Get PDF
    Traditionally oral appliances i.e. removable orthodontic appliances, bite splints and snoring / sleep apnea appliances are made with alginate impressions and wax registrations. Our aim was to describe the process of manufacturing customized oral appliances with a new technique i.e. rapid tooling method. The appliance should ideally be custom made to match the teeth. An orthodontic patient, scheduled for conventional orthodontic treatment, served as a study subject. After a precise clinical and radiographic examination, the approach was to digitize the patient’s dental arches and then to correct them virtually by computer. Additive manufacturing was then used to fabricate a mould for a soft customized appliance. The mould was manufactured using stereolithography from Somos ProtoGen O-XT 18420 material. Casting material for the mould to obtain the final appliance was silicone. As a result we managed to create a customized soft orthodontic appliance. Also, the accuracy of the method was found to be adequate. Two versions of the described device were manufactured: one with small and one with moderate orthodontic force. The study person also gave information on the subjective patient adaptation aspects of the oral appliance

    Generic acquisition protocol for quantitative MRI of the spinal cord

    Get PDF
    Quantitative spinal cord (SC) magnetic resonance imaging (MRI) presents many challenges, including a lack of standardized imaging protocols. Here we present a prospectively harmonized quantitative MRI protocol, which we refer to as the spine generic protocol, for users of 3T MRI systems from the three main manufacturers: GE, Philips and Siemens. The protocol provides guidance for assessing SC macrostructural and microstructural integrity: T1-weighted and T2-weighted imaging for SC cross-sectional area computation, multi-echo gradient echo for gray matter cross-sectional area, and magnetization transfer and diffusion weighted imaging for assessing white matter microstructure. In a companion paper from the same authors, the spine generic protocol was used to acquire data across 42 centers in 260 healthy subjects. The key details of the spine generic protocol are also available in an open-access document that can be found at https://github.com/spine-generic/protocols. The protocol will serve as a starting point for researchers and clinicians implementing new SC imaging initiatives so that, in the future, inclusion of the SC in neuroimaging protocols will be more common. The protocol could be implemented by any trained MR technician or by a researcher/clinician familiar with MRI acquisition

    Search for slow magnetic monopoles with the NOvA detector on the surface

    Get PDF
    We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment’s Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of 2 × 10−14 cm−2 s−1 sr−1 at 90% C.L. for monopole speed 6 × 10−4 < β < 5 × 10−3 and mass greater than 5 × 108 GeV. Because of NOvA’s small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region

    First measurement of neutrino oscillation parameters using neutrinos and antineutrinos by NOvA

    Get PDF
    The NOvA experiment has seen a 4.4σ signal of ν̄e appearance in a 2 GeV ν̄μ beam at a distance of 810 km. Using 12.33×1020 protons on target delivered to the Fermilab NuMI neutrino beamline, the experiment recorded 27 ν̄μ→ν̄e candidates with a background of 10.3 and 102 ν̄μ→ν̄μ candidates. This new antineutrino data are combined with neutrino data to measure the parameters |Δm322|=2.48-0.06+0.11×10-3 eV2/c4 and sin2θ23 in the ranges from (0.53-0.60) and (0.45-0.48) in the normal neutrino mass hierarchy. The data exclude most values near δCP=π/2 for the inverted mass hierarchy by more than 3σ and favor the normal neutrino mass hierarchy by 1.9σ and θ23 values in the upper octant by 1.6σ
    corecore