50 research outputs found

    Stress distribution in the trochlear notch

    Get PDF
    n 16 cadaver humeroulnar joints, the distribution of subchondral mineralisation was assessed by CT osteoabsorptiometry and the position and size of the contact areas by polyether casting under loads of 10 N to 1280 N. Ulnas with separate olecranon and coronoid cartilaginous surfaces showed matching bicentric patterns of mineralisation. Under small loads there were separate contact areas on the olecranon and coronoid surfaces; these areas merged centrally as the load increased. They occupied as little as 9% of the total articular surface at 10 N and up to 73% at 1280 N. Ulnas with continuous cartilaginous surfaces also had density patterns with two maxima but those were less prominent, and in these specimens the separate contact areas merged at lower loads. The findings indicate a physiological incongruity of the articular surfaces which may serve to optimise the distribution of stress

    Physiological incongruity of the humero-ulnar joint

    Get PDF
    Investigations into the distribution of subchondral bone density in the human elbow have suggested that the geometry of the trochlear notch deviates from a perfect fit with the trochlea, and that the load is transmitted ventrally and dorsally rather than through the centre of the humero-ulnar joint. We therefore decided to make a quantitative assessment of the degree of incongruity between the two components in 15 human specimens (age distribution 60 to 93 years) with different types of joint surface. Polyether casts of the joint cavity were prepared under loads of 10,40,160 and 640 N. The thickness of the casts was then measured at 50 predetermined points, and an area distribution of the width of the joint space represented in a two-dimensional template of the trochlear notch. The reproducibility of this procedure was tested by image analysis. At a load of 10 N, only a narrow space was present ventrally and dorsally in the joint, but in the depths of the trochlear notch a width of 0.5 to 1 mm was recorded in the centre, and up to 3 mm at its medial and lateral edges. Specimens with continuous articular cartilage showed a lower degree of incongruity than those with a divided articular surface. As the load was increased to 640 N, however, the original incongruity between the articular surfaces disappeared almost completely. The joint surfaces became more congruous, probably because of the viscoelastic properties of the articular cartilage and the subchondral bone, and the contact areas merged in the centre of the joint. It is suggested that this physiological incongruity brings about an optimal distribution of stress over the articular surface during the transmission of the load, and it may lead to better nourishment of the articular cartilage by providing intermittent mechanical stimulation and circulation of the synovial fluid

    Computed tomography-osteoabsorptiometry for assessing the density distribution of subchondral bone as a measure of long-term mechanical adaptation in individual joints

    Get PDF
    To estimate subchondral mineralisation patterns which represent the long-term loading history of individual joints, a method has been developed employing computed tomography (CT) which permits repeated examination of living joints. The method was tested on 5 knee, 3 sacroiliac, 3 ankle and 5 shoulder joints and then investigated with X-ray densitometry. A CT absorptiometric presentation and maps of the area distribution of the subchondral bone density areas were derived using an image analyser. Comparison of the results from both X-ray densitometry and CT-absorptiometry revealed almost identical pictures of distribution of the subchondral bone density. The method may be used to examine subchondral mineralisation as a measure of the mechanical adaptability of joints in the living subject
    corecore