2,152 research outputs found
Endoscopic palliative management of esophageal and tracheal rupture
The increasing number of patients requiring intensive care and airway support has led to a growing recognition that significant short- and long-term morbidity may be associated with the use of artificial airways;
this is despite significant improvements
in the materials used in laryngeal
tubes, which aim to decrease the trauma
associated with long-term intubation.
We present the first case, to our knowledge,of huge, nontraumatic, esophageal perforation, widely communicating with the trachea, and which was treated successfully with double endoscopic stent placement
The artificial retina for track reconstruction at the LHC crossing rate
We present the results of an R&D study for a specialized processor capable of
precisely reconstructing events with hundreds of charged-particle tracks in
pixel and silicon strip detectors at , thus suitable for
processing LHC events at the full crossing frequency. For this purpose we
design and test a massively parallel pattern-recognition algorithm, inspired to
the current understanding of the mechanisms adopted by the primary visual
cortex of mammals in the early stages of visual-information processing. The
detailed geometry and charged-particle's activity of a large tracking detector
are simulated and used to assess the performance of the artificial retina
algorithm. We find that high-quality tracking in large detectors is possible
with sub-microsecond latencies when the algorithm is implemented in modern,
high-speed, high-bandwidth FPGA devices.Comment: 3 pages, 3 figures, ICHEP14. arXiv admin note: text overlap with
arXiv:1409.089
Surgical treatment of solitary sternal metastasis from breast cancer Case report
Bone metastasis is a frequent and early complication of breast cancer. This case report describes a technique for a partial exeresis of the sternum and the reconstruction of the pleura with autologous dermis from the lower abdomen and the loss of substance with a myocutaneous flap
Thoracoscopy in pleural effusion –two techniques: awake single-access video-assisted thoracic surgery versus 2-ports video-assisted thoracic surgery under general anesthesia
Awake single access video-assisted thoracic surgery with local anesthesia improves procedure tolerance, reduces postoperative stay and costs.
MATERIALS & METHODS: Local anesthesia was made with lidocaine and ropivacaine. We realize one 20 mm incision for the 'single-access', and two incisions for the '2-trocars technique'.
RESULTS: Mortality rate was 0% in both groups. Postoperative stay: 3dd ± 4 versus 4dd ± 5, mean operative time: 39 min versus 37 min (p < 0.05). Chest tube duration: 2dd ± 5 versus 3dd ± 6.
COMPLICATIONS: 11/95 versus 10/79.
CONCLUSION: Awake technique reduce postoperative hospital stay and chest drainage duration, similar complications and recurrence rate. The authors can say that 'awake single-access VATS' is an optimal diagnostic and therapeutic tool for the management of pleural effusions, but above extends surgical indication to high-risk patients
First prototype of a silicon tracker using an artificial retina for fast track finding
We report on the R\&D for a first prototype of a silicon tracker based on an
alternative approach for fast track finding. The working principle is inspired
from neurobiology, in particular by the processing of visual images by the
brain as it happens in nature. It is based on extensive parallelisation of data
distribution and pattern recognition. In this work we present the design of a
practical device that consists of a telescope based on single-sided silicon
detectors; we describe the data acquisition system and the implementation of
the track finding algorithms using available digital logic of commercial FPGA
devices. Tracking performance and trigger capabilities of the device are
discussed along with perspectives for future applications.Comment: 9 pages, 7 figures, Technology and Instrumentation in Particle
Physics 2014 (TIPP 2014), conference proceeding
Trocar-related abdominal wall bleeding in 200 patients after laparoscopic cholecistectomy: Personal experience
AIM: To determine the complications and incidence of the first and second access-related vascular injuries induced by videolaparoscopic cholecistectomy.
METHODS: We retrospectively reviewed vascular injuries in 200 consecutive patients who underwent videolaparoscopic cholecistectomy from 2003 to 2005. One hundred and one patients with placement of radial expanding trocars were assigned into group A and 99 patients with placement of pyramidal tipped trocars into group B. All the patients were submitted to open access according to Hasson for the first trocar.
RESULTS: Bleeding did not occur at the intraoperative cannula-site in group A. However, it occurred at the intraoperative cannula-site of 7 patients (7.1%) in group B, with a statistically significant difference (P < 0.01). No mortality was registered. More vascular lesions were found in group B.
CONCLUSION: The advantage of Hasson technique is that peritoneal cavity access is gained under direct vision, preventing most severe injuries. The open technique with radial expanding trocars is recommended for secure access to the abdominal cavity in videolaparoscopy. Great care should be taken to avoid major complications and understanding the abdominal wall anatomy is important for reducing bleeding during or after s placement of trocars
Whole genome semiconductor based sequencing of farmed European sea bass (Dicentrarchus labrax) Mediterranean genetic stocks using a DNA pooling approach
European sea bass (Dicentrarchus labrax) is an important marine species for commercial and sport fisheries and aquaculture production. Recently, the European sea bass genome has been sequenced and assembled. This resource can open new opportunities to evaluate and monitor variability and identify variants that could contribute to the adaptation to farming conditions. In this work, two DNA pools constructed from cultivated European sea bass were sequenced using a next generation semiconductor sequencing approach based on Ion Proton sequencer. Using the first draft version of the D. labrax genome as reference, sequenced reads obtained a total of about 1.6 million of single nucleotide polymorphisms (SNPs), spread all over the chromosomes. Transition/transversion (Ti/Tv) was equal to 1.28, comparable to what was already reported in Salmon species. A pilot homozygosity analysis across the D. labrax genome using DNA pool sequence datasets indicated that this approach can identify chromosome regions with putative signatures of selection, including genes involved in ion transport and chloride channel functions, amino acid metabolism and circadian clock and related neurological systems. This is the first study that reported genome wide polymorphisms in a fish species obtained with the Ion Proton sequencer. Moreover, this study provided a methodological approach for selective sweep analysis in this species
Alpha-particle clustering in excited expanding self-conjugate nuclei
The fragmentation of quasi-projectiles from the nuclear reaction 40Ca + 12C
at 25 MeV/nucleon was used to produce alpha-emission sources. From a careful
selection of these sources provided by a complete detection and from
comparisons with models of sequential and simultaneous decays, strong
indications in favour of -particle clustering in excited 16O, 20Ne and
24}Mg are reported.Comment: 8 pages, 4 figures, 12th International Conference on Nucleus-Nucleus
collisions (NN2015), 21-26 June 2015, Catania, Ital
Simulation and performance of an artificial retina for 40 MHz track reconstruction
We present the results of a detailed simulation of the artificial retina
pattern-recognition algorithm, designed to reconstruct events with hundreds of
charged-particle tracks in pixel and silicon detectors at LHCb with LHC
crossing frequency of . Performances of the artificial retina
algorithm are assessed using the official Monte Carlo samples of the LHCb
experiment. We found performances for the retina pattern-recognition algorithm
comparable with the full LHCb reconstruction algorithm.Comment: Final draft of WIT proceedings modified according to JINST referee's
comment
- …
