12 research outputs found

    External quality assessment of molecular biology-based methods used in laboratories of clinical chemistry and human genetics

    Get PDF
    The Reference Institute of Bioanalysis of the German Society of Clinical Chemistry has performed the first external assessment of molecular genetics methods used in medical diagnosis. The following procedures were tested: (I) DNA preparation from whole blood, (II) PCR amplification using "standard" primers, and (III) submarine agarose gel electrophoresis. Out of 50 participants, 45 returned samples for evaluation

    Methodologic European External Quality Assurance for DNA Sequencing: The EQUALseq Program

    Get PDF
    Abstract Background: DNA sequencing is a key technique in molecular diagnostics, but to date no comprehensive methodologic external quality assessment (EQA) programs have been instituted. Between 2003 and 2005, the European Union funded, as specific support actions, the EQUAL initiative to develop methodologic EQA schemes for genotyping (EQUALqual), quantitative PCR (EQUALquant), and sequencing (EQUALseq). Here we report on the results of the EQUALseq program. Methods: The participating laboratories received a 4-sample set comprising 2 DNA plasmids, a PCR product, and a finished sequencing reaction to be analyzed. Data and information from detailed questionnaires were uploaded online and evaluated by use of a scoring system for technical skills and proficiency of data interpretation. Results: Sixty laboratories from 21 European countries registered, and 43 participants (72%) returned data and samples. Capillary electrophoresis was the predominant platform (n = 39; 91%). The median contiguous correct sequence stretch was 527 nucleotides with considerable variation in quality of both primary data and data evaluation. The association between laboratory performance and the number of sequencing assays/year was statistically significant (P <0.05). Interestingly, more than 30% of participants neither added comments to their data nor made efforts to identify the gene sequences or mutational positions. Conclusions: Considerable variations exist even in a highly standardized methodology such as DNA sequencing. Methodologic EQAs are appropriate tools to uncover strengths and weaknesses in both technique and proficiency, and our results emphasize the need for mandatory EQAs. The results of EQUALseq should help improve the overall quality of molecular genetics findings obtained by DNA sequencing

    International descriptive and interventional survey for oxycholesterol determination by gas- and liquid-chromatographic methods

    Get PDF
    Increasing numbers of laboratories develop new methods based on gas-liquid and high-performance liquid chromatography to determine serum concentrations of oxygenated cholesterol metabolites such as 7α-, 24(S)-, and 27-hydroxycholesterol. We initiated a first international descriptive oxycholesterol (OCS) survey in 2013 and a second interventional survey 2014 in order to compare levels of OCS reported by different laboratories and to define possible sources of analytical errors. In 2013 a set of two lyophilized serum pools (A and B) was sent to nine laboratories in different countries for OCS measurement utilizing their own standard stock solutions. In 2014 eleven laboratories were requested to determine OCS concentrations in lyophilized pooled sera (C and D) utilizing the same provided standard stock solutions of OCS. The participating laboratories submitted results obtained after capillary gas-liquid chromatography-mass selective detection with either epicoprostanol or deuterium labelled sterols as internal standards and high-performance liquid chromatography with mass selective detection and deuterated OCS as internal standard. Each participant received a clear overview of the results in form of Youden-Plots and basic statistical evaluation in its used unit. The coefficients of variation of the concentrations obtained by all laboratories using their individual methods were 58.5–73.3% (survey 1), 56.8–60.3% (survey 2); 36.2–35.8% (survey 1), 56.6–59.8, (survey 2); 61.1–197.7% (survey 1), 47.2–74.2% (survey 2) for 24(S)-, 27-, and 7α-hydroxycholesterol, respectively. We are surprised by the very great differences between the laboratories, even under conditions when the same standards were used. The values of OCS's must be evaluated in relation to the analytical technique used, the efficiency of the ample separation and the nature of the internal standard used. Quantification of the calibration solution and inappropriate internal standards could be identified as major causes for the high variance in the reported results from the different laboratories. A harmonisation of analytical standard methods is highly needed

    First international descriptive and interventional survey for cholesterol and non-cholesterol sterol determination by gas- and liquid- chromatography–Urgent need for harmonisation of analytical methods

    Get PDF
    Serum concentrations of lathosterol, the plant sterols campesterol and sitosterol and the cholesterol metabolite 5α-cholestanol are widely used as surrogate markers of cholesterol synthesis and absorption, respectively. Increasing numbers of laboratories utilize a broad spectrum of well-established and recently developed methods for the determination of cholesterol and non-cholesterol sterols (NCS). In order to evaluate the quality of these measurements and to identify possible sources of analytical errors our group initiated the first international survey for cholesterol and NCS. The cholesterol and NCS survey was structured as a two-part survey which took place in the years 2013 and 2014. The first survey part was designed as descriptive, providing information about the variation of reported results from different laboratories. A set of two lyophilized pooled sera (A and B) was sent to twenty laboratories specialized in chromatographic lipid analysis. The different sterols were quantified either by gas chromatography-flame ionization detection, gas chromatography- or liquid chromatography-mass selective detection. The participants were requested to determine cholesterol and NCS concentrations in the provided samples as part of their normal laboratory routine. The second part was designed as interventional survey. Twenty-two laboratories agreed to participate and received again two different lyophilized pooled sera (C and D). In contrast to the first international survey, each participant received standard stock solutions with defined concentrations of cholesterol and NCS. The participants were requested to use diluted calibration solutions from the provided standard stock solutions for quantification of cholesterol and NCS. In both surveys, each laboratory used its own internal standard (5α-cholestane, epicoprostanol or deuterium labelled sterols). Main outcome of the survey was, that unacceptably high interlaboratory variations for cholesterol and NCS concentrations are reported, even when the individual laboratories used the same calibration material. We discuss different sources of errors and recommend all laboratories analysing cholesterol and NCS to participate in regular quality control programs
    corecore