13 research outputs found

    Status Quo der Biodiversitätsbewertung in Ökobilanzen

    Get PDF
    During the last years the demand and use of Life Cycle Assessment (LCA) for calculating and comparing the ecological impacts of agricultural products has increased. However, within LCA important environmental impacts of agriculture, for instance biodiversity, soil quality or animal welfare are considered inadequately or stay unaccounted. In the case of biodiversity agriculture is considered as the main driver for the worldwide biodiversity loss. Thus, biodiversity cannot be neglected in future agricultural LCAs. Even though there is no widely accepted approach yet, a lot of research has been undertaken to solve the question how biodiversity can be assessed in the LCA framework. Within a literature review eleven studies with biodiversity assessment approaches for Life Cycle Impact Assessment (LCIA) were analysed and compared. The results of this review will be the basis for the development of a new LCIA method for biodiversit

    Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis.

    Get PDF
    BACKGROUND Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA. AIM To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS. METHODS Fifty-six patients (43 males; mean age 62 years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24 months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded. RESULTS At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month. CONCLUSIONS The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions. https://clinicaltrials.gov/ct2/show/NCT01532427

    Successful treatment of COVID-19 infection with convalescent plasma in B-cell-depleted patients may promote cellular immunity

    Full text link
    Treatment with convalescent plasma has been shown to be safe in coronavirus disease in 2019 (COVID-19) infection, although efficacy reported in immunocompetent patients varies. Nevertheless, neutralizing antibodies are a key requisite in the fight against viral infections. Patients depleted of antibody-producing B cells, such as those treated with rituximab (anti-CD20) for hematological malignancies, lack a fundamental part of their adaptive immunity. Treatment with convalescent plasma appears to be of general benefit in this particularly vulnerable cohort. We analyzed clinical course and inflammation markers of three B-cell-depleted patients suffering from COVID-19 who were treated with convalescent plasma. In addition, we measured serum antibody levels as well as peripheral blood CD38/HLA-DR-positive T-cells ex vivo and CD137-positive T-cells after in vitro stimulation with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-derived peptides in these patients. We observed that therapy with convalescent plasma was effective in all three patients and analysis of CD137-positive T-cells after stimulation with SARS-CoV-2 peptides showed an increase in peptide-specific T-cells after application of convalescent plasma. In conclusion, we here demonstrate efficacy of convalescent plasma therapy in three B-cell-depleted patients and present data that suggest that while application of convalescent plasma elevates systemic antibody levels only transiently, it may also boost specific T-cell responses

    Increased serum miR-193a-5p during non-alcoholic fatty liver disease progression: diagnostic and mechanistic relevance

    Get PDF
    Background & Aims: Serum microRNAs (miRNAs) levels are known to change in non-alcoholic fatty liver disease (NAFLD) and may serve as useful biomarkers. This study aimed to profile miRNAs comprehensively at all NAFLD stages.Methods: We profiled 2,083 serum miRNAs in a discovery cohort (183 NAFLD cases representing the complete NAFLD spectrum and 10 population controls). MiRNA libraries generated by HTG EdgeSeq were sequenced by Illumina NextSeq. Selected serum miRNAs were profiled in 372 additional NAFLD cases and 15 population controls by quantitative reverse transcriptase-polymerase chain reaction.Results: Levels of 275 miRNAs differed between cases and population controls. Fewer differences were seen within individual NAFLD stages but miR-193a-5p consistently the showed increased levels in all comparisons. Relative to NAFL/NASH with mild fibrosis (stage 0/1), three miRNAs (miR-193a-5p, miR-378d and miR378d) were increased in cases with NASH and clinically significant fibrosis (stage 2-4), seven (miR193a-5p, miR-378d, miR-378e, miR-320b, c, d & e) increased in cases with NAFLD Activity Score (NAS) 5-8 compared with lower NAS, and three (miR-193a-5p, miR-378d, miR-378e) increased but one (miR-19b-3p) decreased in steatosis, activity, and fibrosis "activity" (SAF-A) score 2-4 compared with lower SAF-A. The significant findings for miR-193a-5p were replicated in the additional NAFLD cohort. Studies in Hep G2 cells showed that following palmitic acid treatment, miR-193a-5p expression decreased significantly. Gene targets for miR-193a-5p were investigated in liver RNAseq data for a case subgroup (n=80); liver GPX8 levels correlated positively with serum miR-193a-5p. Conclusions: Serum miR-193a-5p levels correlate strongly with NAFLD activity grade and fibrosis stage. MiR-193a-5p may have a role in the hepatic response to oxidative stress and is a potential clinically tractable circulating biomarker for progressive NAFLD

    Final safety and efficacy results from a 106 real-world patients registry with an ascites-mobilizing pump

    Get PDF
    Background and aims: Patients with cirrhotic refractory ascites ineligible for transjugular intrahepatic shunt (TIPSS) have limited treatment options apart from repeated large volume paracentesis. The alfapump® is an implantable device mobilizing ascites from the peritoneal cavity to the bladder, from where it can be excreted. The aim of this observational cohort study was to prospectively investigate safety and efficacy of the device in a real-world cohort with cirrhotic refractory ascites and contraindications for TIPSS. Methods: A total of 106 patients received an implant at 12 European centres and were followed up for up to 24 months. Complications, device deficiencies, frequency of paracentesis, clinical status and survival were recorded prospectively. Results: Approximately half of the patients died on-study, about a quarter was withdrawn because of serious adverse events leading to explant, a sixth were withdrawn because of liver transplant or recovery, and nine completed follow-up. The most frequent causes of on-study death and complication-related explant were progression of liver disease and infection. The device reduced the requirement for large-volume paracentesis significantly, with more than half of patients not having required any post-implant. Survival benefits were not observed. Device-related reinterventions were predominantly caused by device deficiencies. A post-hoc comparison of the first 50 versus the last 50 patients enrolled revealed a decreased reintervention rate in the latter, mainly related to peritoneal catheter modifications. Conclusions: The device reduced paracentesis frequency in a real-world setting. Technical complications were successfully decreased by optimization of management and device modification (NCT01532427)

    Final Safety and Efficacy Results from a 106 Real-World Patients Registry with an Ascites-Mobilizing Pump.

    No full text
    BACKGROUND & AIMS Patients with cirrhotic refractory ascites ineligible for transjugular intrahepatic shunt (TIPSS) have limited treatment options apart from repeated large volume paracentesis. The alfapump® is an implantable device mobilizing ascites from the peritoneal cavity to the bladder, from where it can be excreted. The aim of this observational cohort study was to prospectively investigate safety and efficacy of the device in a real-world cohort with cirrhotic refractory ascites and contraindications for TIPSS. METHODS A total of 106 patients received an implant at twelve European centers and were followed up for up to 24 months. Complications, device deficiencies, frequency of paracentesis, clinical status and survival were recorded prospectively. RESULTS Approximately half of the patients died on-study, about a quarter were withdrawn due to serious adverse events leading to explant, a sixth were withdrawn due to liver transplant or recovery, and nine completed follow-up. The most frequent causes of on-study death and complication-related explant were progression of liver disease and infection. The device reduced the requirement for large volume paracentesis significantly, with more than half of patients not having required any post-implant. Survival benefits were not observed. Device-related reinterventions were predominantly caused by device deficiencies. A post-hoc comparison of the first 50 vs. the last 50 patients enrolled revealed a decreased reintervention rate in the latter, mainly related to peritoneal catheter modifications. CONCLUSIONS The device reduced paracentesis frequency in a real-world setting. Technical complications were successfully decreased by optimization of management and device modification (NCT01532427)

    Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis

    No full text
    Background: Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA. Aim: To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS. Methods: Fifty-six patients (43 males; mean age 62 years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24 months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded. Results: At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month. Conclusions: The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions

    Protein Kinase D2 drives chylomicron‐mediated lipid transport in the intestine and promotes obesity

    No full text
    Abstract Lipids are the most energy‐dense components of the diet, and their overconsumption promotes obesity and diabetes. Dietary fat content has been linked to the lipid processing activity by the intestine and its overall capacity to absorb triglycerides (TG). However, the signaling cascades driving intestinal lipid absorption in response to elevated dietary fat are largely unknown. Here, we describe an unexpected role of the protein kinase D2 (PKD2) in lipid homeostasis. We demonstrate that PKD2 activity promotes chylomicron‐mediated TG transfer in enterocytes. PKD2 increases chylomicron size to enhance the TG secretion on the basolateral side of the mouse and human enterocytes, which is associated with decreased abundance of APOA4. PKD2 activation in intestine also correlates positively with circulating TG in obese human patients. Importantly, deletion, inactivation, or inhibition of PKD2 ameliorates high‐fat diet‐induced obesity and diabetes and improves gut microbiota profile in mice. Taken together, our findings suggest that PKD2 represents a key signaling node promoting dietary fat absorption and may serve as an attractive target for the treatment of obesity
    corecore