29 research outputs found

    Biomechanical evaluation of combined short segment fixation and augmentation of incomplete osteoporotic burst fractures

    Full text link
    Background: Treating traumatic fractures in osteoporosis is challenging. Multiple clinical treatment options are found in literature. Augmentation techniques are promising to reduce treatment-related morbidity. In recent years, there have been an increasing number of reports about extended indication for augmentation techniques. However, biomechanical evaluations of these techniques are limited. Methods: Nine thoracolumbar osteoporotic spinal samples (4 FSU) were harvested from postmortem donors and immediately frozen. Biomechanical testing was performed by a robotic-based spine tester. Standardized incomplete burst fractures were created by a combination of osteotomy-like weakening and high velocity compression using a hydraulic material testing apparatus. Biomechanical measurements were performed on specimens in the following conditions: 1) intact, 2) fractured, 3) bisegmental instrumented, 4) bisegmental instrumented with vertebroplasty (hybrid augmentation, HA) and 5) stand-alone vertebroplasty (VP). The range of motion (RoM), neutral zone (NZ), elastic zone (EZ) and stiffness parameters were determined. Statistical evaluation was performed using Wilcoxon signed-rank test for paired samples (p = 0.05). Results: Significant increases in RoM and in the NZ and EZ (p < 0.005) were observed after fracture production. The RoM was decreased significantly by applying the dorsal bisegmental instrumentation to the fractured specimens (p < 0.005). VP reduced fractured RoM in flexion but was still increased significantly (p < 0.05) above intact kinematic values. NZ stiffness (p < 0.05) and EZ stiffness (p < 0.01) was increased by VP but remained lower than prefracture values. The combination of short segment instrumentation and vertebroplasty (HA) showed no significant changes in RoM and stiffness in NZ in comparison to the instrumented group, except for significant increase of EZ stiffness in flexion (p < 0.05). Conclusions: Stand-alone vertebroplasty (VP) showed some degree of support of the anterior column but was accompanied by persistent traumatic instability. Therefore, we would advocate against using VP as a stand-alone procedure in traumatic fractures. HA did not increase primary stability of short segment instrumentation. Some additional support of anterior column and changes of kinematic values of the EZ may lead one to suppose that additive augmentation may reduce the load of dorsal implants and possibly reduce the risk of implant failure.<br

    Графическое сопровождение международной конференции, посвященной изучению творчества японского писателя Акутагава Рюноске

    Get PDF
    Графическое сопровождение мероприятия на Восточном факультете в 2018 годуVisual identity of the event at the Eastern faculty in 201

    Venous injection of a triphasic calcium-based implant in a sheep model of pulmonary embolism demonstrates minimal acute systemic effects.

    Get PDF
    PURPOSE Implant leakage is the most common complication of vertebral augmentation. Alternative injectable materials must demonstrate intravascular safety comparable to or better than polymethyl methacrylate (PMMA). This study assessed the systemic effects of a triphasic calcium-based implant or PMMA injected directly into the femoral vein in a large animal model designed to mimic severe intravascular implant leakage. METHODS Six skeletally mature female sheep were randomly assigned (n = 3) to either the PMMA or the triphasic implant (AGN1, composition: calcium sulfate, β-tricalcium phosphate, brushite) treatment group. Femoral veins of each sheep were directly injected with 0.5 mL of implant material to mimic leakage volumes reported during PMMA vertebroplasty. To compare acute systemic effects of the materials, cardiovascular parameters, laboratory coagulation markers, and calcium and sulfate serum levels were monitored for 60 min after implant injection. Thrombotic and embolic events were evaluated by radiologic imaging, necropsy, and histopathology. RESULTS Heart rate, systemic arterial blood pressure, arterial oxygenation, arterial carbon dioxide content, and coagulation markers remained within physiological range after either AGN1 or PMMA injection. No blood flow interruption in the larger pulmonary vessels was observed in either group. Lung histopathology revealed that the severity of thrombotic changes after AGN1 injection was minimal to slight, while changes after PMMA injection were minimal to massive. CONCLUSION Acute systemic effects of intravascular AGN1 appeared to be comparable to or less than that of intravascular PMMA. Furthermore, in this preliminary study, the severity and incidence of pulmonary histological changes were lower for AGN1 compared to PMMA

    Experimentally induced incomplete burst fractures - a novel technique for calf and human specimens

    Full text link
    Background: Fracture morphology is crucial for the clinical decision-making process preceding spinal fracture treatment. The presented experimental approach was designed in order to ensure reproducibility of induced fracture morphology. Results: The presented method resulted in fracture morphology, found in clinical classification systems like the Magerl classification. In the calf spine samples, 70% displayed incomplete burst fractures corresponding to type A3.1 and A3.2 fractures. In all human samples, superior incomplete burst fractures (Magerl A3.1) were identified by an independent radiologist and spine surgeon. Conclusions: The presented set up enables the first experimental means to reliably model and study distinct incomplete burst fracture patterns in an in vitro setting. Thus, we envisage this protocol to facilitate further studies on spine fracture treatment of incomplete burst fractures

    Comparison and optimization of sheep in vivo intervertebral disc injury model.

    Get PDF
    Background The current standard of care for intervertebral disc (IVD) herniation, surgical discectomy, does not repair annulus fibrosus (AF) defects, which is partly due to the lack of effective methods to do so and is why new repair strategies are widely investigated and tested preclinically. There is a need to develop a standardized IVD injury model in large animals to enable comparison and interpretation across preclinical study results. The purpose of this study was to compare in vivo IVD injury models in sheep to determine which annulus fibrosus (AF) defect type combined with partial nucleus pulposus (NP) removal would better mimic degenerative human spinal pathologies. Methods Six skeletally mature sheep were randomly assigned to one of the two observation periods (1 and 3 months) and underwent creation of 3 different AF defect types (slit, cruciate, and box-cut AF defects) in conjunction with 0.1 g NP removal in three lumbar levels using a lateral retroperitoneal surgical approach. The spine was monitored by clinical CT scans pre- and postoperatively, at 2 weeks and euthanasia, and by magnetic resonance imaging (MRI) and histology after euthanasia to determine the severity of degeneration (disc height loss, Pfirrmann grading, semiquantitative histopathology grading). Results All AF defects led to significant degenerative changes detectable on CT and MR images, produced bulging of disc tissue without disc herniation and led to degenerative and inflammatory histopathological changes. However, AF defects were not equal in terms of disc height loss at 3 months postoperatively; the cruciate and box-cut AF defects showed significantly decreased disc height compared to their preoperative height, with the box-cut defect creating the greatest disc height loss, while the slit AF defect showed restoration of normal preoperative disc height. Conclusions The tested IVD injury models do not all generate comparable disc degeneration but can be considered suitable IVD injury models to investigate new treatments. Results of the current study clearly indicate that slit AF defect should be avoided if disc height is used as one of the main outcomes; additional confirmatory studies may be warranted to generalize this finding

    Interlaboratory comparison of femur surface reconstruction from CT data compared to reference optical 3D scan

    Get PDF
    Background: The present study contrasts the accuracy of different reconstructed models with distinctive segmentation methods performed by various experts. Seven research groups reconstructed nine 3D models of one human femur based on an acquired CT image using their own computational methods. As a reference model for accuracy assessment, a 3D surface scan of the human femur was created using an optical measuring system. Prior to comparison, the femur was divided into four areas;"neck and greater trochanter", "proximal metaphysis", "diaphysis", and "distal metaphysis". The deviation analysis was carried out in GEOMAGIC studio v. 2013 software. Results: The results revealed that the highest deviation errors occurred in "neck and greater trochanter" area and "proximal metaphysis" area with RMSE of 0.84 and 0.83 mm respectively. Conclusion: In conclusion, this study shows that the average deviation of reconstructed models prepared by experts with various methods, skills and software from the surface 3D scan is lower than 0.79 mm, which is not a significant discrepancy

    Orbital floor repair using patient specific osteoinductive implant made by stereolithography

    Get PDF
    The orbital floor (OF) is an anatomical location in the craniomaxillofacial (CMF) region known to be highly variable in shape and size. When fractured, implants commonly consisting of titanium meshes are customized by plying and crude hand-shaping. Nevertheless, more precise customized synthetic grafts are needed to meticulously reconstruct the patients’ OF anatomy with better fidelity. As alternative to titanium mesh implants dedicated to OF repair, we propose a flexible patient-specific implant (PSI) made by stereolithography (SLA), offering a high degree of control over its geometry and architecture. The PSI is made of biodegradable poly(trimethylene carbonate) (PTMC) loaded with 40 wt % of hydroxyapatite (called Osteo-PTMC). In this work, we developed a complete work-flow for the additive manufacturing of PSIs to be used to repair the fractured OF, which is clinically relevant for individualized medicine. This work-flow consists of (i) the surgical planning, (ii) the design of virtual PSIs and (iii) their fabrication by SLA, (iv) the monitoring and (v) the biological evaluation in a preclinical large-animal model. We have found that once implanted, titanium meshes resulted in fibrous tissue encapsulation, whereas Osteo-PMTC resulted in rapid neovascularization and bone morphogenesis, both ectopically and in the OF region, and without the need of additional biotherapeutics such as bone morphogenic proteins. Our study supports the hypothesis that the composite osteoinductive Osteo-PTMC brings advantages compared to standard titanium mesh, by stimulating bone neoformation in the OF defects. PSIs made of Osteo-PTMC represent a significant advancement for patients whereby the anatomical characteristics of the OF defect restrict the utilization of traditional hand-shaped titanium mesh

    Removal of cement-augmented screws in distal femoral fractures and the effect of retained screws and cement on total knee arthroplasty: a biomechanical investigation

    No full text
    Wähnert D, Grüneweller N, Gueorguiev B, Vordemvenne T, Gehweiler D. Removal of cement-augmented screws in distal femoral fractures and the effect of retained screws and cement on total knee arthroplasty: a biomechanical investigation. Journal of Orthopaedics and Traumatology. 2021;22(1): 5.**Background** Given the increasing number of osteoporotic fractures of the distal femur, screw augmentation with bone cement is an option to enhance implant anchorage. However, in implant removal or revision surgeries, the cement cannot be removed from the distal femur without an extended surgical procedure. Therefore, the aims of this study were to investigate (1) whether cement augmentation has any influence on screw removal and removal torque, and (2) whether the implantation of a femoral component of a knee arthroplasty and its initial interface stability are affected by the remaining screws/cement. **Material and methods** Eight pairs of fresh-frozen human female cadaveric distal femurs (mean age, 86 years) with a simulated AO/OTA 33 A3 fracture were randomized in paired fashion to two groups and fixed with a distal femoral locking plate using cannulated perforated locking screws. Screw augmentation with bone cement was performed in one of the groups, while the other group received no screw augmentation. Following biomechanical testing until failure (results published separately), the screws were removed and the removal torque was measured. A femoral component of a knee arthroplasty was then implanted, and pull-out tests were performed after cement curing. Interference from broken screws/cement was assessed, and the maximum pull-out force was measured. **Results** The mean screw removal torque was not significantly different between the augmented (4.9 Nm, SD 0.9) and nonaugmented (4.6 Nm, SD 1.3,p = 0.65) screw groups. However, there were significantly more broken screws in in the augmented screw group (17 versus 9;p p = 0.94) screw groups. **Conclusion** The screw removal torque during implant removal surgery does not significantly differ between augmented and nonaugmented screws. In the augmented screw group, significantly more screws failed. To overcome this, the use of solid screws in holes B, C, and G can be considered. Additionally, it is possible to implant a femoral component for knee arthroplasty that retains the initial anchorage and does not suffer from interference with broken screws and/or residual cement. **Level of Evidence**

    Local bone quality measure and construct failure prediction: a biomechanical study on distal femur fractures

    No full text
    Gehweiler D, Styger U, Gueorguiev B, Colcuc C, Vordemvenne T, Wähnert D. Local bone quality measure and construct failure prediction: a biomechanical study on distal femur fractures. Archives of Orthopaedic and Trauma Surgery. 2022;142(6):1055-1061.Introduction The aim of this investigation was to better understand the differences in local bone quality at the distal femur and their correlation with biomechanical construct failure, with the intention to identify regions of importance to optimize implant anchorage. Materials and methods Seven fresh–frozen female femurs underwent high-resolution peripheral quantitative computed tomography (HR-pQCT) to determine bone mineral density (BMD) within three different regions of interest (distal, intermedium, and proximal) at the distal femur. In addition, local bone quality was assessed by measuring the peak torque necessary to break out the trabecular bone along each separate hole of a locking compression plate (LCP) during its instrumentation. Finally, biomechanical testing was performed using cyclic axial loading until failure in an AO/OTA 33 A3 fracture model. Results Local BMD was highest in the distal region. This was confirmed by the measurement of local bone quality using DensiProbe™. The most distal holes represented locations with the highest breakaway torque resistance, with the holes on the posterior side of the plate indicating higher values than those on its anterior side. We demonstrated strong correlation between the cycles to failure and local bone strength (measured with DensiProbe™) in the most distal posterior screw hole, having the highest peak torque. Conclusion The local bone quality at the distal femur indicates that in plated distal femur fractures the distal posterior screw holes seem to be the key ones and should be occupied. Measurement of the local bone strength with DensiProbe™ is one possibility to determine the risk of construct failure, therefore, thresholds need to be defined

    Material properties of human vertebral trabecular bone under compression can be predicted based on quantitative computed tomography

    No full text
    Gehweiler D, Schultz M, Schulze M, Riesenbeck O, Wähnert D, Raschke MJ. Material properties of human vertebral trabecular bone under compression can be predicted based on quantitative computed tomography. BMC Musculoskeletal Disorders. 2021;22(1): 709.**Background** The prediction of the stability of bones is becoming increasingly important. Especially osteoporotic vertebral body fractures are a growing problem and an increasing burden on the health system. Therefore, the aim of this study was to provide the best possible description of the relationship between the material properties of human vertebral trabecular bone measured under the most physiological conditions possible and the bone mineral density (BMD) determined by clinical quantitative computed tomography (QCT). **Methods** Forty eight cylindric cancellous bone samples with a diameter of 7.2 mm obtained from 13 human fresh-frozen lumbar vertebrae from 5 donors (3 men, 2 women) have been used for this study. After the specimens were temporarily reinserted into the vertebral body, the QCT was performed. For mechanical testing, the samples were embedded in a load-free manner using polymethylmetacrylate (PMMA). The surrounding test chamber was filled with phosphate buffered saline (PBS) and heated to 37 °C during the test. After 10 preconditioning load cycles, destructive testing was performed under axial compression. After determining the fracture site, BMD has been evaluated in this region only. Regression analyses have been performed. **Results** Fracture site had an average length of 2.4 (±1.4) mm and a position of 43.9 (±10.9) percent of the measurement length from the cranial end. No fracture reached the embedding. The average BMD at the fracture site was 80.2 (±28.7 | min. 14.5 | max. 137.8) mgCaHA/ml. In summary the results of the regression analyses showed for all three parameters a very good quality of fit by a power regression. **Conclusion** The results of this study show that QCT-based bone density measurements have a good predictive power for the material properties of the vertebral cancellous bone measured under near to physiological conditions. The mechanical bone properties of vertebral cancellous bone could be modelled with high accuracy in the investigated bone density range