567 research outputs found

    Linking urban design to sustainability : formal indicators of social urban sustainability field research in Perth, Western Australia

    Get PDF
    The making of a livable urban community is a complex endeavor. For much of the 20th Century plannersand engineers believed that modern and rational decision-making would create successful cities. Today, political leaders across the globe are considering ways to promote sustainable development and the concepts of New Urbanism are making their way from the drawing board to the ground. While much has changed in the world, the creation of a successful street is as much of an art today as it was in the 1960s.Our work seeks to investigate 'street life' in cities as a crucial factor towards community success. What arethe components of the neighborhood and street form that contributes to the richness of street life? To answer this question we rely on the literature. The aim of the Formal Indicators of Social Urban Sustainability studyis to measure the formal components of a neighborhood and street that theorists have stated important in promoting sustainability. This paper will describe how this concept helps to bridge urban design and sustainability. It will describe the tool and show how this was applied in a comparative assessment of Joondalup and Fremantle, two urban centers in the Perth metropolitan area

    Product Service System Innovation in the Smart City

    Get PDF
    Product service systems (PSS) may usefully form part of the mix of innovations necessary to move society toward more sustainable futures. However, despite such potential, PSS implementation is highly uneven and limited. Drawing on an alternate socio-technical perspective of innovation, this paper provides fresh insights, on among other things the role of context in PSS innovation, to address this issue. Case study research is presented focusing on a use orientated PSS in an urban environment: the Copenhagen city bike scheme. The paper shows that PSS innovation is a situated complex process, shaped by actors and knowledge from other locales. It argues that further research is needed to investigate how actors interests shape PSS innovation. It recommends that institutional spaces should be provided in governance landscapes associated with urban environments to enable legitimate PSS concepts to co-evolve in light of locally articulated sustainability principles and priorities

    Rapid earthquake loss updating of spatially distributed systems via sampling-based bayesian inference

    Get PDF
    Within moments following an earthquake event, observations collected from the affected area can be used to define a picture of expected losses and to provide emergency services with accurate information. A Bayesian Network framework could be used to update the prior loss estimates based on ground-motion prediction equations and fragility curves, considering various field observations (i.e., evidence). While very appealing in theory, Bayesian Networks pose many challenges when applied to real-world infrastructure systems, especially in terms of scalability. The present study explores the applicability of approximate Bayesian inference, based on Monte-Carlo Markov-Chain sampling algorithms, to a real-world network of roads and built areas where expected loss metrics pertain to the accessibility between damaged areas and hospitals in the region. Observations are gathered either from free-field stations (for updating the ground-motion field) or from structure-mounted stations (for the updating of the damage states of infrastructure components). It is found that the proposed Bayesian approach is able to process a system comprising hundreds of components with reasonable accuracy, time and computation cost. Emergency managers may readily use the updated loss distributions to make informed decisions

    Characterization of 1D photonic crystal nanobeam cavities using curved microfiber

    Get PDF
    We investigate high-Q, small mode volume photonic crystal nanobeam cavities using a curved, tapered optical microfiber loop. The strength of the coupling between the cavity and the microfiber loop is shown to depend on the contact position on the nanobeam, angle between the nanobeam and the microfiber, and polarization of the light in the fiber. The results are compared to a resonant scattering measurement

    Comparative Study of Vented vs. Unvented Crawlspaces

    Get PDF
    There has been a significant amount of research in the area of building energy efficiency and durability. However, well-documented quantitative information on the impact of crawlspaces on the performance of residential structures is lacking. The objective of this study was to evaluate and compare the effects of two crawlspace strategies on the whole-house performance of a pair of houses in a mixed humid climate. These houses were built with advanced envelope systems to provide energy savings of 50% or more compared to traditional 2010 new construction. One crawlspace contains insulated walls and is sealed and semi-conditioned. The other is a traditional vented crawlspace with insulation in the crawlspace ceiling. The vented (traditional) crawlspace contains fiberglass batts installed in the floor chase cavities above the crawl, while the sealed and insulated crawlspace contains foil-faced polyisocyanurate foam insulation on the interior side of the masonry walls. Various sensors to measure temperatures, heat flux through crawlspace walls and ceiling, and relative humidity were installed in the two crawlspaces. Data from these sensors have been analyzed to compare the performance of the two crawlspace designs. The analysis results indicated that the sealed and insulated crawlspace design is better than the traditional vented crawlspace in the mixed humid climate

    Effect of atomic layer deposition on the quality factor of silicon nanobeam cavities

    Get PDF
    In this work we study the effect of thin-film deposition on the quality factor (Q) of silicon nanobeam cavities. We observe an average increase in the Q of 38±31% in one sample and investigate the dependence of this increase on the initial nanobeam hole sizes. We note that this process can be used to modify cavities that have larger than optimal hole sizes following fabrication. Additionally, the technique allows the tuning of the cavity mode wavelength and the incorporation of new materials, without significantly degrading Q

    Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

    Get PDF
    Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use
    corecore