11 research outputs found

    Characterizing reproducibility of cerebral hemodynamic responses when applying short-channel regression in functional near-infrared spectroscopy

    Full text link
    Significance: Functional near-infrared spectroscopy (fNIRS) enables the measurement of brain activity noninvasively. Optical neuroimaging with fNIRS has been shown to be reproducible on the group level and hence is an excellent research tool, but the reproducibility on the single-subject level is still insufficient, challenging the use for clinical applications. Aim: We investigated the effect of short-channel regression (SCR) as an approach to obtain fNIRS measurements with higher reproducibility on a single-subject level. SCR simultaneously considers contributions from long- and short-separation channels and removes confounding physiological changes through the regression of the short-separation channel information. Approach: We performed a test-retest study with a hand grasping task in 15 healthy subjects using a wearable fNIRS device, optoHIVE. Relevant brain regions were localized with transcranial magnetic stimulation to ensure correct placement of the optodes. Reproducibility was assessed by intraclass correlation, correlation analysis, mixed effects modeling, and classification accuracy of the hand grasping task. Further, we characterized the influence of SCR on reproducibility. Results: We found a high reproducibility of fNIRS measurements on a single-subject level ( and correlation ). SCR increased the reproducibility from 0.64 to 0.81 ( ) but did not affect classification (85% overall accuracy). Significant intersubject variability in the reproducibility was observed and was explained by Mayer wave oscillations and low raw signal strength. The raw signal-to-noise ratio (threshold at 40 dB) allowed for distinguishing between persons with weak and strong activations. Conclusions: We report, for the first time, that fNIRS measurements are reproducible on a single-subject level using our optoHIVE fNIRS system and that SCR improves reproducibility. In addition, we give a benchmark to easily assess the ability of a subject to elicit sufficiently strong hemodynamic responses. With these insights, we pave the way for the reliable use of fNIRS neuroimaging in single subjects for neuroscientific research and clinical applications

    Characterizing reproducibility of cerebral hemodynamic responses when applying short-channel regression in functional near-infrared spectroscopy.

    Get PDF
    Significance: Functional near-infrared spectroscopy (fNIRS) enables the measurement of brain activity noninvasively. Optical neuroimaging with fNIRS has been shown to be reproducible on the group level and hence is an excellent research tool, but the reproducibility on the single-subject level is still insufficient, challenging the use for clinical applications. Aim: We investigated the effect of short-channel regression (SCR) as an approach to obtain fNIRS measurements with higher reproducibility on a single-subject level. SCR simultaneously considers contributions from long- and short-separation channels and removes confounding physiological changes through the regression of the short-separation channel information. Approach: We performed a test-retest study with a hand grasping task in 15 healthy subjects using a wearable fNIRS device, optoHIVE. Relevant brain regions were localized with transcranial magnetic stimulation to ensure correct placement of the optodes. Reproducibility was assessed by intraclass correlation, correlation analysis, mixed effects modeling, and classification accuracy of the hand grasping task. Further, we characterized the influence of SCR on reproducibility. Results: We found a high reproducibility of fNIRS measurements on a single-subject level ( and correlation ). SCR increased the reproducibility from 0.64 to 0.81 ( ) but did not affect classification (85% overall accuracy). Significant intersubject variability in the reproducibility was observed and was explained by Mayer wave oscillations and low raw signal strength. The raw signal-to-noise ratio (threshold at 40 dB) allowed for distinguishing between persons with weak and strong activations. Conclusions: We report, for the first time, that fNIRS measurements are reproducible on a single-subject level using our optoHIVE fNIRS system and that SCR improves reproducibility. In addition, we give a benchmark to easily assess the ability of a subject to elicit sufficiently strong hemodynamic responses. With these insights, we pave the way for the reliable use of fNIRS neuroimaging in single subjects for neuroscientific research and clinical applications

    Comparison of CT, MRI, and F-18 FDG PET/CT for initial N-staging of oral squamous cell carcinoma: a cost-effectiveness analysis.

    Get PDF
    BACKGROUND AND PURPOSE Treatment of oral squamous cell carcinoma (OSCC) is based on clinical exam, biopsy, and a precise imaging-based TNM-evaluation. A high sensitivity and specificity for magnetic resonance imaging (MRI) and F-18 FDG PET/CT are reported for N-staging. Nevertheless, staging of oral squamous cell carcinoma is most often based on computed tomography (CT) scans. This study aims to evaluate cost-effectiveness of MRI and PET/CT compared to standard of care imaging in initial staging of OSCC within the US Healthcare System. METHODS A decision model was constructed using quality-adjusted life years (QALYs) and overall costs of different imaging strategies including a CT of the head, neck, and the thorax, MRI of the neck with CT of the thorax, and whole body F-18 FDG PET/CT using Markov transition simulations for different disease states. Input parameters were derived from literature and willingness to pay (WTP) was set to US 100,000/QALY.Deterministicsensitivityanalysisofdiagnosticparametersandcostswasperformed.MonteCarlomodelingwasusedforprobabilisticsensitivityanalysis.RESULTSInthebasecasescenario,totalcostswereatUS100,000/QALY. Deterministic sensitivity analysis of diagnostic parameters and costs was performed. Monte Carlo modeling was used for probabilistic sensitivity analysis. RESULTS In the base-case scenario, total costs were at US 239,628 for CT, US 240,001forMRI,andUS240,001 for MRI, and US 239,131 for F-18 FDG PET/CT whereas the model yielded an effectiveness of 5.29 QALYs for CT, 5.30 QALYs for MRI, and 5.32 QALYs for F-18 FDG PET/CT respectively. F-18 FDG PET/CT was the most cost-effective strategy over MRI as well as CT, and MRI was the cost-effective strategy over CT. Deterministic and probabilistic sensitivity analysis showed high robustness of the model with incremental cost effectiveness ratio remaining below US $100,000/QALY for a wide range of variability of input parameters. CONCLUSION F-18 FDG PET/CT is the most cost-effective strategy in the initial N-staging of OSCC when compared to MRI and CT. Despite less routine use, both whole body PET/CT and MRI are cost-effective modalities in the N-staging of OSCC. Based on these findings, the implementation of PET/CT for initial staging could be suggested to help reduce costs while increasing effectiveness in OSCC

    SNR analysis of contrast-enhanced MR imaging for early detection of rheumatoid arthritis.

    No full text
    OBJECTIVE:To investigate whether signal to noise (SNR) analysis of contrast-enhanced MRI gives additional benefit for early disease detection by Magnetic Resonance Imaging (MRI) of experimental rheumatoid arthritis (RA) in a small animal model. METHODS:We applied contrast-enhanced MRI at 7T in DBA mice with or without collagen-induced arthritis (CIA). Clinical score, OMERACT RAMRIS analysis and analysis of signal to noise ratios (SNR) of regions of interest in RA bearing mice, methotrexate/methylprednisolone acetate treated RA and control animals were compared with respect to benefit for early diagnosis. RESULTS:While treated RA and control animals did not show signs of RA activity in any of the above-mentioned scoring methods at any time point analyzed, RA animals revealed characteristic signs of RA in RAMRIS at the same time point when RA was detected clinically through scoring of the paws. The MR-based SNR analysis detected signs of synovitis, the earliest indication of RA, not only in late clinical stages, but also at an early stage when little or no clinical signs of RA were present in CIA animals and RAMRIS did not allow a distinct early detection. CONCLUSION:SNR analysis of contrast-enhanced MR imaging provides additional benefit for early arthritis detection in CIA mice

    Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT

    No full text
    The aim of this study is to assess whether perifocal bone marrow edema (BME) in patients with osteoid osteoma (OO) can be accurately detected on dual-layer spectral CT (DLCT) with three-material decomposition. To that end, 18 patients with OO (25.33 ± 12.44 years; 7 females) were pairwise-matched with 18 patients (26.72 ± 9.65 years; 9 females) admitted for suspected pathologies other than OO in the same anatomic location but negative imaging findings. All patients were examined with DLCT and MRI. DLCT data was decomposed into hydroxyapatite and water- and fat-equivalent volume fraction maps. Two radiologists assessed DLCT-based volume fraction maps for the presence of perifocal BME, using a Likert scale (1 = no edema; 2 = likely no edema; 3 = likely edema; 4 = edema). Accuracy, sensitivity, and specificity for the detection of BME on DLCT were analyzed using MR findings as standard of reference. For the detection of BME in patients with OO, DLCT showed a sensitivity of 0.92, a specificity of 0.94, and an accuracy of 0.92 for both radiologists. Interreader agreement for the assessment of BME with DLCT was substantial (weighted κ = 0.78; 95% CI, 0.59, 0.94). DLCT with material-specific volume fraction maps allowed accurate detection of BME in patients with OO. This may spare patients additional examinations and facilitate the diagnosis of OO

    18F FDG PET/MRI with hepatocyte-specific contrast agent for M staging of rectal cancer: a primary economic evaluation

    No full text
    Purpose!#!Rectal cancer is one of the most frequent causes of cancer-related morbidity and mortality in the world. Correct identification of the TNM state in primary staging of rectal cancer has critical implications on patient management. Initial evaluations revealed a high sensitivity and specificity for whole-body PET/MRI in the detection of metastases allowing for metastasis-directed therapy regimens. Nevertheless, its cost-effectiveness compared with that of standard-of-care imaging (SCI) using pelvic MRI + chest and abdominopelvic CT is yet to be investigated. Therefore, the aim of this study was to analyze the cost-effectiveness of whole-body !##!Methods!#!For estimation of quality-adjusted life years (QALYs) and lifetime costs of diagnostic modalities, a decision model including whole-body !##!Results!#!In the base-case scenario, the strategy whole-body !##!Conclusion!#!Based on the results of the analysis, use of whole-bod

    K2S Challenge: From Undersampled K-Space to Automatic Segmentation

    Get PDF
    Magnetic Resonance Imaging (MRI) offers strong soft tissue contrast but suffers from long acquisition times and requires tedious annotation from radiologists. Traditionally, these challenges have been addressed separately with reconstruction and image analysis algorithms. To see if performance could be improved by treating both as end-to-end, we hosted the K2S challenge, in which challenge participants segmented knee bones and cartilage from 8× undersampled k-space. We curated the 300-patient K2S dataset of multicoil raw k-space and radiologist quality-checked segmentations. 87 teams registered for the challenge and there were 12 submissions, varying in methodologies from serial reconstruction and segmentation to end-to-end networks to another that eschewed a reconstruction algorithm altogether. Four teams produced strong submissions, with the winner having a weighted Dice Similarity Coefficient of 0.910 ± 0.021 across knee bones and cartilage. Interestingly, there was no correlation between reconstruction and segmentation metrics. Further analysis showed the top four submissions were suitable for downstream biomarker analysis, largely preserving cartilage thicknesses and key bone shape features with respect to ground truth. K2S thus showed the value in considering reconstruction and image analysis as end-to-end tasks, as this leaves room for optimization while more realistically reflecting the long-term use case of tools being developed by the MR community

    Literaturverzeichnis

    No full text
    corecore