10,196 research outputs found

    Laser velocimeter measurements of the flowfield generated by an advanced counterrotating propeller

    Get PDF
    Results are presented of an investigation to measure the flowfield generated by an advanced counterrotating pusher propeller model similar to the full-scale Unducted Fan demonstrator engine. A laser Doppler velocimeter was used to measure the velocity field in several planes normal to the centerline of the model at axial stations upstream and downstream of each rotor. During this investigation, blades of the F4/A4 type were installed on the model which was operating in a freestream Mach 0.72 regime, with the advance ratio of each rotor set at 2.80. The measured data indicate only a slight influence of the potential field of each front rotor blade on the flowfield upstream of the rotor. The data measured downstream of the front rotor characterize the tip vortices, vortex sheets and potential field nonuniformities generated by the front rotor. The unsteadiness of the flow in the rotating frame of reference of the aft rotor is also illustrated

    Blade-to-Blade Variations in Shocks Upstream of Both a Forward-Swept and an Aft-Swept Fan

    Get PDF
    Detailed laser Doppler velocimeter (LDV) flow field measurements were made upstream of two fans, one forward-swept and one aft-swept, in order to learn more about the shocks which propagate upstream of these rotors when they are operated at supersonic tip speeds. The blade-to-blade variations in the flows associated with these shocks are thought to be responsible for generating Multiple Pure Tone (MPT) noise. The measured blade-to-blade variations are documented in this report through a series of slideshows which show relative Mach number contours computed from the velocity measurements. Data are presented for the forward-swept fan operating at three speeds (corresponding to tip relative Mach numbers of 0.817, 1.074, and 1.189), and for the aft-swept fan operating at two (tip relative Mach numbers of 1.074 and 1.189). These LDV data illustrate how the perturbations in the upstream flow field created by the rotating blades vary with axial position, radial position and rotor speed. As expected, at the highest tested speed the forward-swept fan swallowed the shocks which occur in the tip region, whereas the aftswept fan did not. This resulted in a much smaller flow disturbance just upstream of the tip of the forward-swept fan. Nevertheless, further upstream the two fan flows were much more similar

    Laser velocimeter measurements of the flow field generated by a forward-swept propfan during flutter

    Get PDF
    Results are presented from an investigation to measure the flow field generated by a forward-swept propfan operating in flutter at a low forward velocity. For comparison to the flutter condition, flow field data are also presented for a slightly reduced rotational speed just below flutter. The forward-swept propfan was tested as the front rotor of a counterrotating pusher propeller. A laser Doppler velocimeter (LDV) was used to measure the velocity field in planes normal to the model centerline downstream of the rotor and in planes of constant radius within the blade passages at each operating condition. A comparison of the data taken at the two different operating conditions indicated that the mean, time-averaged flow about the blades did not change drastically as the propfan rotational speed was increased from the stable operating point to the flutter condition. No regions of flow separation could be identified in the data plots of the mean intrablade flow field. The data also indicate that the relative flow about the blades remained subsonic during flutter operation. The blades were found to have a higher than expected tip loading at both operating conditions. This is thought to have been caused by the outer blade sections twisting under load to higher than expected effective blade angles. This high tip loading resulted in strong vortices and a very nonuniform flow downstream of the tips of the forward-swept blades. This high tip loading may also have caused the blade flutter

    Spatio-temporal dynamics of Marbled Murrelet hotspots during nesting in nearshore waters along the Washington to California coast

    Get PDF
    The Marbled Murrelet, Brachyramphus marmoratus, is a federally listed alcid that forages in nearshore waters of the Pacific Northwest, and nests in adjacent older-forest conifers within 40-80 km of shore. To estimate abundance and distribution of murrelets, we conduct at-sea surveys from May to July each year, starting in 2000 and continuing to present. We record numbers of individuals sighted by using distance-based transects and compute annual estimates of density after adjusting for detectability. At-sea transects are subdivided into 5-km segments, and we summarized mean and variance of density at each segment in Puget Sound and along the coast from the Canadian border South to San Francisco Bay. We used a boosted regression tree analysis to investigate the contributions of marine and terrestrial attributes on murrelet abundance in each segment. We observed that terrestrial attributes, especially the amount and pattern of suitable nesting habitat in proximity to each segment, made the strongest contribution, but that marine attributes also helped explain variation in murrelet abundance. Hotspots of murrelet abundance therefore reflect not only suitable marine foraging habitat but proximity of suitable inland nesting habitat

    The Primordial Helium Abundance: Toward Understanding and Removing the Cosmic Scatter in the \u3cem\u3eDY/DZ\u3c/em\u3e Relation

    Get PDF
    We present results from photoionization models of low-metallicity H II regions. These nebulae form the basis for measuring the primordial helium abundance. Our models show that the helium ionization correction factor (ICF) can be nonnegligible for nebulae excited by stars with effective temperatures larger than 40,000 K. Furthermore, we find that when the effective temperature rises to above 45,000 K, the ICF can be significantly negative. This result is independent of the choice of stellar atmosphere. However, if an H II region has an [O III] λ5007/[O I] λ6300 ratio greater than 300, then our models show that, regardless of its metallicity, it will have a negligibly small ICF. A similar, but metallicity-dependent, result was found using the [O III] λ5007/Hβ ratio. These two results can be used as selection criteria to remove nebulae with potentially nonnegligible ICFs. Use of our metallicity-independent criterion on the data of Izotov & Thuan results in a 20% reduction of the rms scatter about the best-fit Y-Z line. A fit to the selected data results in a slight increase of the value of the primordial helium abundance

    Variability in the α and β anomer content of commercially available lactose

    Get PDF
    Lactose, a disaccharide is a ubiquitous excipient in many pharmaceutical formulations which exists in two anomeric forms; either as - or -lactose. The anomers have different properties which can affect their application. Nevertheless, batches of lactose products are widely produced by many manufacturers, and is available in many grades. However, the anomeric content of these batches has not been accurately characterized and reported previously. Therefore, the aim of this study was to analyse a set of 19 commercially available samples of lactose using a novel H⁠1-NMR technique to establish a library showing the anomeric content of a large range of lactose products. The lactose samples were also analysed by DSC. The anomeric content of the -lactose monohydrate samples were found to vary by more than 10%, which might in_uence bioavailability from ^nal formulations. The data showed that there is a need to determine and monitor the anomeric content of lactose and this should be a priority to both manufacturers and formulators of medicines

    Dose de-escalation of intrapleural tissue plasminogen activator therapy for pleural infection. The alteplase dose assessment for Pleural infection Therapy project

    Get PDF
    Rationale: Intrapleural therapy with a combination of tissue plasminogen activator (tPA) 10 mg and DNase 5 mg administered twice daily has been shown in randomized and open-label studies to successfully manage over 90% of patients with pleural infection without surgery. Potential bleeding risks associated with intrapleural tPA and its costs remain important concerns. The aim of the ongoing Alteplase Dose Assessment for Pleural infection Therapy (ADAPT) project is to investigate the efficacy and safety of dose de-escalation for intrapleural tPA. The first of several planned studies is presented here. Objectives: To evaluate the efficacy and safety of a reduced starting dose regimen of 5 mg of tPA with 5 mg of DNase administered intrapleurally for pleural infection. Methods: Consecutive patients with pleural infection at four participating centers in Australia, the United Kingdom, and New Zealand were included in this observational, open-label study. Treatment was initiated with tPA 5 mg and DNase 5 mg twice daily. Subsequent dose escalation was permitted at the discretion of the attending physician. Data relating to treatment success, radiological and systemic inflammatory changes (blood C-reactive protein), volume of fluid drained, length of hospital stay, and treatment complications were extracted retrospectively from the medical records. Results: We evaluated 61 patients (41 males; age, 57 ± 16 yr). Most patients (n = 58 [93.4%]) were successfully treated without requiring surgery for pleural infection. Treatment success was corroborated by clearance of pleural opacities visualized by chest radiography (from 42% [interquartile range, 22–58] to 16% [8–31] of hemithorax; P < 0.001), increase in pleural fluid drainage (from 175 ml in the 24 h preceding treatment to 2,025 ml [interquartile range, 1,247–2,984] over 72 h of therapy; P <  0.05) and a reduction in blood C-reactive protein (P < 0.05). Seven patients (11.5%) had dose escalation of tPA to 10 mg. Three patients underwent surgery. Three patients (4.9%) received blood transfusions for gradual pleural blood loss; none were hemodynamically compromised. Pain requiring escalation of analgesia affected 36% of patients; none required cessation of therapy. Conclusions: These pilot data suggest that a starting dose of 5 mg of tPA administered intrapleurally twice daily in combination with 5 mg of DNase for the treatment of pl

    Shock Characteristics Measured Upstream of Both a Forward-Swept and an Aft-Swept Fan

    Get PDF
    Three different types of diagnostic data-blade surface flow visualization, shroud unsteady pressure, and laser Doppler velocimeter (LDV)--were obtained on two fans, one forward-swept and one aft-swept, in order to learn more about the shocks which propagate upstream of these rotors when they are operated at transonic tip speeds. Flow visualization data are presented for the forward-swept fan operating at 13831 rpm(sub c), and for the aft-swept fan operating at 12500 and 13831 rpm(sub c) (corresponding to tip rotational Mach numbers of 1.07 and 1.19, respectively). The flow visualization data identify where the shocks occur on the suction side of the rotor blades. These data show that at the takeoff speed, 13831 rpm(sub c), the shocks occurring in the tip region of the forward-swept fan are further downstream in the blade passage than with the aft-swept fan. Shroud unsteady pressure measurements were acquired using a linear array of 15 equally-spaced pressure transducers extending from two tip axial chords upstream to 0.8 tip axial chords downstream of the static position of the tip leading edge of each rotor. Such data are presented for each fan operating at one subsonic and five transonic tip speeds. The unsteady pressure data show relatively strong detached shocks propagating upstream of the aft-swept rotor at the three lowest transonic tip speeds, and weak, oblique pressure disturbances attached to the tip of the aft-swept fan at the two highest transonic tip speeds. The unsteady pressure measurements made with the forward-swept fan do not show strong shocks propagating upstream of that rotor at any of the tested speeds. A comparison of the forward-swept and aft-swept shroud unsteady pressure measurements indicates that at any given transonic speed the pressure disturbance just upstream of the tip of the forward-swept fan is much weaker than that of the aft-swept fan. The LDV data suggest that at 12500 and 13831 rpm(sub c), the forward-swept fan swallowed the passage shocks occurring in the tip region of the blades, whereas the aft-swept fan did not. Due to this difference, the flows just upstream of the two fans were found to be quite different at both of these transonic speeds. Nevertheless, despite distinct differences just upstream of the two rotors, the two fan flows were much more alike about one axial blade chord further upstream. As a result, the LDV data suggest that it is unwise to attempt to determine the effect that the shocks have on far field noise by focusing only on measurements (or CFD predictions) made very near the rotor. Instead, these data suggest that it is important to track the shocks throughout the inlet
    corecore