79 research outputs found
Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty 163,368 hip replacements in the Nordic Arthroplasty Register Association database with 5-11 years of follow-up
Background and purpose - Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis.Patients and methods - Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups).Results - The CPE version of the ZCA cup had a risk of revision for any reason similar to that of the XLPE version (p = 0.09), but showed a 6-fold higher risk of revision for aseptic loosening (p < 0.001). The CPE version of the Reflection All Poly cup had an 8-fold elevated risk of revision for any reason (p < 0.001) and a 5-fold increased risk of revision for aseptic loosening (p < 0.001). The Charnley Elite Ogee/Marathon cup and the Trilogy cup did not show such differences.Interpretation Whether XLPE has any advantage over CPE regarding revision risk may depend on the properties of the polyethylene materials being compared, as well as the respective cup designs, fixation type, and follow-up times. Further research is needed to elucidate how cup design factors interact with polyethylene type to affect the risk of revision
A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years
Background and purpose: We performed a randomized study to determine the migration patterns of the Spectron EF femoral stem and to compare them with those of the Charnley stem, which is regarded by many as the gold standard for comparison of implants due to its extensive documentation. Patients and methods: 150 patients with a mean age of 70 years were randomized, single-blinded, to receive either a cemented Charnley flanged 40 monoblock, stainless steel, vaquasheen surface femoral stem with a 22.2-mm head (n = 30) or a cemented Spectron EF modular, matte, straight, collared, cobalt-chrome femoral stem with a 28-mm femoral head and a roughened proximal third of the stem (n = 120). The patients were followed with repeated radiostereometric analysis for 2 years to assess migration. Results: At 2 years, stem retroversion was 2.3° and 0.7° (p < 0.001) and posterior translation was 0.44 mm and 0.17 mm (p = 0.002) for the Charnley group (n = 26) and the Spectron EF group (n = 74), respectively. Subsidence was 0.26 mm for the Charnley and 0.20 mm for the Spectron EF (p = 0.5). Interpretation: The Spectron EF femoral stem was more stable than the Charnley flanged 40 stem in our study when evaluated at 2 years. In a report from the Norwegian arthroplasty register, the Spectron EF stem had a higher revision rate due to aseptic loosening beyond 5 years than the Charnley. Initial stability is not invariably related to good long-term results. Our results emphasize the importance of prospective long-term follow-up of prosthetic implants in clinical trials and national registries and a stepwise introduction of implants
Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database
Background and purpose According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA based on the NARA database, which has not been done previously.Patients and methods We determined the rate of implant survival of the 9 most common cemented THAs in the NARA database. We used Kaplan-Meier analysis with 95% CI to study implant survival at 10 and 15 years, and Cox multiple regression to assess survival and hazard ratios (HRs), with revision for any reason as endpoint and with adjustment for age, sex, diagnosis, and femoral head material.Results Spectron EF THA (89.9% (CI: 89.3-90.5)) and Elite THA (89.8% (CI: 89.0-90.6)) had the lowest 10-year survivorship. Lubinus (95.7% survival, CI: 95.5-95.9), MS 30 (96.6%, CI: 95.8-97.4), and C-stem THA (95.8%, CI: 94.8-96.8) had a 10-year survivorship of at least 95%. Lubinus (revision risk (RR)=0.77, CI: 0.73-0.81), Muller (RR =0.83, CI: 0.70-0.99), MS-30 (RR =0.73, CI: 0.63-0.86), C-stem (RR =0.70, CI: 0.55-0.90), and Exeter Duration THA (RR =0.84, CI: 0.77-0.90) had a lower risk of revision than Charnley THA, the reference implant.Interpretation The Spectron EF THA and the Elite THA had a lower implant survival than the Charnley, Exeter, and Lubinus THAs. Implant survival of the Muller, MS 30, CPT, and C-stem THAs was above the acceptable limit for 10-year survival
Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty: Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007
Today, total hip arthroplasty (THA) is one of the safest and most efficient surgical treatments. New materials, surgical techniques and design concepts intended to improve THA have not always been successful. Thorough preclinical and early clinical investigations can detect some aspects of under-performing, while continuing surveillance is recommended to detect and analyze reasons for any later appearing flaws. In this thesis, several ways to monitor and assess THA performance are explored and carried out, using survival analysis in registry studies, radiostereometry (RSA), radiology and clinical outcome.
In Paper I, a study using the Nordic Arthroplasty Register Association (NARA) registry shows that HRA had an almost 3-fold increased early non-septic revision risk and that risk factors were found to be female sex, certain HRA designs and units having performed few HRA procedures. Papers II and III contain comparisons of highly cross-linked polyethylene (XLPE) and conventional polyethylene (PE). XLPE had a considerably lower wear rate up to 10 years but showed no obvious improvements regarding implant fixation, BMD or clinical outcome. In the NARA registry, in 2 of 4 studied cup designs the XLPE version had a lower risk of revision for aseptic loosening compared to the PE version. Paper IV describes that stem subsidence and retrotorsion measured with RSA at 2 years predicted later aseptic stem failure in an unfavorably altered, previously well-functioning cemented femoral stem. In Paper V and VI, a novel approach to measure articulation wear with RSA in radiodense hip arthroplasty articulations was presented and evaluated. Subsequently, a comparison between ceramic-on-ceramic (COC) and metal-on-conventional PE uncemented THA displayed a considerably lower wear rate, smaller periacetabular bone lesions and a relatively high squeaking rate, the latter with unknown long-term consequences, in the COC hips. Implant fixation, heterotopic ossification and clinical outcome did not differ between articulation types.
In conclusion, it was confirmed that implant surveillance can be done with RSA, also in radiodense THA. Early migration predicts later aseptic implant failure. Prolonged surveillance can confirm long-term material and design performance, verify or contradict anticipated advantages as well as detect unanticipated long-term complications
18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register: Concerns about some newer implants
Background and purpose Few studies have compared the long-term survival of cemented primary total hip arthroplasties (THAs), and several prostheses have been used without adequate knowledge of their endurance. We studied long-term outcome based on data in the Norwegian Arthroplasty Register
Evaluating comorbidities in total hip and knee arthroplasty: available instruments
Each year millions of patients are treated for joint pain with total joint arthroplasty, and the numbers are expected to rise. Comorbid disease is known to influence the outcome of total joint arthroplasty, and its documentation is therefore of utmost importance in clinical evaluation of the individual patient as well as in research. In this paper, we examine the various methods for obtaining and assessing comorbidity information for patients undergoing joint replacement. Multiple instruments are reliable and validated for this purpose, such as the Charlson Index, Index of Coexistent Disease, and the Functional Comorbidity Index. In orthopedic studies, the Charnley classification and the American Society of Anesthesiologists physical function score (ASA) are widely used. We recommend that a well-documented comorbidity index that incorporates some aspect of mental health is used along with other appropriate instruments to objectively assess the preoperative status of the patient
Linking Swedish health data registers to establish a research database and a shared decision-making tool in hip replacement.
Sweden offers a unique opportunity to researchers to construct comprehensive databases that encompass a wide variety of healthcare related data. Statistics Sweden and the National Board of Health and Welfare collect individual level data for all Swedish residents that ranges from medical diagnoses to socioeconomic information. In addition to the information collected by governmental agencies the medical profession has initiated nationwide Quality Registers that collect data on specific diagnoses and interventions. The Quality Registers analyze activity within healthcare institutions, with the aims of improving clinical care and fostering clinical research.This article is freely available via Open Access. Click on the Additional Link above to access the full-text via the publisher's site
- …