6 research outputs found
Removal of a migrated biliary stent using new digital cholangioscopy retrieval devices in a transplant patient
A 51-year-old man who had undergone liver transplantation developed a symptomatic anastomotic biliary stricture 23 months after surgery. Endoscopic biliary therapy via endoscopic retrograde cholangiopancreatography (ERCP) was planned. Progressive biliary balloon dilation of the stenosis was performed, with placement of three coaxial plastic stents (8.5-Fr × 12 cm, 8.5-Fr × 9 cm, and 10-Fr × 12 cm; Advanix, Boston Scientific, Natick, Massachusetts, USA). During an endoscopy to replace the stents, fluoroscopy revealed proximal migration of an 8.5-Fr plastic stent at the level of the cystic insertion ([Fig. 1]). Several failed extraction attempts were made using the standard ERCP techniques (i. e. extractor balloon, Lasso technique, and others) [1] [2]. Single-operator peroral intraductal cholangioscopy (SpyGlass DS direct visualization system, Boston Scientific) confirmed impaction of the distal end of the proximally migrated stent, located 3 cm proximally to the duodenal papilla. An attempt to mobilize the migrated stent was made using biopsy forceps (SpyBite, Boston Scientific), without success
Endoscopic ultrasound-guided transvascular needle biopsy of thoracic and abdominal lesions: a multicenter experience
Background and study aims Traditionally in the case of a vascular interposition, endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has been contraindicated. A transvascular route (TV) is feasible and probably a safe alternative approach in selected patients, but data are scarce. The primary aim of this study was to analyze the diagnostic yield and safety of EUS-TV-FNA in thoracic and abdominal lesions. Secondary aims included evaluation of the clinical impact and technical aspects. Patients and methods A retrospective multicenter study was conducted with inclusion of all consecutive patients that underwent EUS-TV-FNA from July 2007 to January 2020. Feasibility, cytopathology, procedure details, and safety were evaluated. Univariate analysis was performed to identify variables associated with incidents, cytopathological diagnosis, and clinical impact. Results Data were collected from a total of 49 cases and 50 EUS-TV-FNAs. The aorta (n = 19) and portal system (n = 17) were the most frequently punctured. The most frequent lesions were mediastinal lymph nodes (n = 13) and pancreatic tumors (n = 11). The diagnostic yield was 86 %, and there were nondiagnostic samples in seven cases. Overall sensitivity, specificity, and accuracy were 88% (95 % CI, 0.74-0.96), 100% (95 % CI, 0.59-1), and 90% (95 % CI, 0.78-0.96), respectively. Only three incidents were detected: two mural hematomas and a self-limited bleeding of gastroduodenal artery. In most patients, there was a significant impact on clinical management (88%). Arterial vessel and ASA-III had a trend with incidents (both, P < 0.08). Rapid on-site evlauation was found to be an independent predictor for obtaining a conclusive sample (OR 6.2; 95%CI, 1.06-36.73, P < 0.04). Conclusions EUS-TV-FNA is feasible, seems to be safe, and can be recommended when no other targets are available, and the information obtained would impact on the clinical plan
Percutaneous transhepatic or endoscopic ultrasound-guided biliary drainage in malignant distal bile duct obstruction using a self-expanding metal stent: Study protocol for a prospective European multicenter trial (PUMa trial)
Background Endoscopic ultrasound-guided biliary drainage (EUS-BD) was associated with better clinical success and a lower rate of adverse events (AEs) than fluoroscopy-guided percutaneous transhepatic biliary drainage (PTBD) in recent single center studies with mainly retrospective design and small case numbers (< 50). The aim of this prospective European multicenter study is to compare both drainage procedures using ultrasound-guidance and primary metal stent implantation in patients with malignant distal bile duct obstruction (PUMa Trial). Methods The study is designed as a non-randomized, controlled, parallel group, non-inferiority trial. Each of the 16 study centers performs the procedure with the best local expertise (PTBD or EUS-BD). In PTBD, bile duct access is performed by ultrasound guidance. EUS-BD is performed as an endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS), EUS-guided choledochoduodenostomy (EUS-CDS) or EUS-guided antegrade stenting (EUS-AGS). Insertion of a metal stent is intended in both procedures in the first session. Primary end point is technical success. Secondary end points are clinical success, duration pf procedure, AEs graded by severity, length of hospital stay, re-intervention rate and survival within 6 months. The target case number is 212 patients (12 calculated dropouts included). Discussion This study might help to clarify whether PTBD is non-inferior to EUS-BD concerning technical success, and whether one of both interventions is superior in terms of efficacy and safety in one or more secondary endpoints. Randomization is not provided as both procedures are rarely used after failed endoscopic biliary drainage and study centers usually prefer one of both procedures that they can perform best
Multicenter study of lumen-apposing metal stents with or without pigtail in endoscopic ultrasound-guided biliary drainage for malignant obstruction - BAMPI TRIAL: an open-label, randomized controlled trial protocol
Background It is unclear whether the insertion of an axis-orienting double-pigtail plastic stent (DPS) through biliary lumen-apposing meal stent (LAMS) in EUS-guided choledochoduodenostomy (CDS) improves the stent patency. The aim of this study is to determine whether this technical variant offers a clinical benefit in EUS-guided biliary drainage (BD) for the management of distal malignant biliary obstruction. Methods/design This is a multicenter open-label, randomized controlled trial with two parallel groups. Eighty-four patients with malignant biliary obstruction will undergo EUS-BD (CDS type) using LAMS in 7 tertiary hospitals in Spain and will be randomized to the LAMS and LAMS plus DPS groups. The primary endpoint is the rate of recurrent biliary obstruction, as a stent dysfunction parameter, detected during follow-up. Secondary endpoints: technical and clinical success (reduction in bilirubin > 50% within 14 days of stent placement), safety, and others (number of reinterventions, time to biliary obstruction, prognostic factors, survival rate). Discussion The BAMPI trial has been designed to determine whether the addition of a coaxial axis-orienting DPS through LAMS is superior to LAMS alone to prevent stent dysfunction
Adelante / Endavant
SĂ©ptimo desafĂo por la erradicaciĂłn de la violencia contra las mujeres del Institut Universitari d’Estudis Feministes i de Gènere "PurificaciĂłn Escribano" de la Universitat Jaume