706 research outputs found

    Investigation of Application of Suction Line Heat Exchanger in R290 Air Conditioner with Small Diameter Copper Tube

    Get PDF
    R290 is a potential refrigerant replacing R22 because of its zero Ozone Depletion Potential (ODP) and virtually zero Global Warming Potential (GWP). However, R290 is flammable and requires excellent containment to avoid leakage and reduce the risk of fire. The use of small diameter copper tube (5 mm or even smaller) is an effective way to reduce refrigerant charge and thus reduce the risk of fire in the event of a refrigerant leak. However, employing small diameter copper tube will increase pressure drop and consequently reduce system performance. A suction line heat exchanger which employs the low temperature refrigerant in suction line to cool down the refrigerant before expansion value is a potential solution to improve system performance because R290 has low discharge temperature compared with HFC refrigerants (e.g. R22, R410A). This paper presents an investigation of application of a suction line heat exchanger in an R290 air conditioner with small diameter copper tube. A theoretical analysis is proposed at first to investigate the effect of the suction line heat exchanger on capacity and system energy efficiency under variable evaporating and cooling temperatures. A prototype R290 air conditioner with and without a suction line heat exchanger is tested in order to explore the effect of a suction line heat exchanger on system performance and refrigerant charge in real working conditions. Finally, a refrigerant circuit solution for heat pump air conditioners is proposed. The results of theoretical analysis indicate that the capacity and system energy efficiency increase linearly with the heat exchange of the suctionline heat exchanger, and the suction line heat exchanger can improves capacity by up to 12% and system energy efficiency by up to 4% under both cooling and heating modes. This is because the suction line heat exchanger increases the sub-cooling but has less impact on compressor power due to good thermal properties of R290. Further, the evaporating and condensation temperature have insignificant impact on the performance of suction line heat exchanger. The experimental results show that the suction line heat exchanger improves the cooling capacity and system efficiency by 5.3% and 4.5%, respectively. These results agree well with that of the system analysis. The sub-cooling temperature increases 10.2o C and the discharge temperature increases 25.4o C. Further, the suction line heat exchanger reduces the refrigerant charge by as much as 6%. This is because suction line heat exchanger increases the discharge temperature, and thus the superheat region of the condenser increases resulting in less refrigerant in the condenser. Overall, the use of a suction line heat exchanger in a system with small diameter copper tube improves the performance of R290 and more importantly reduces the refrigerant charge

    Following the messenger: Recent innovations in live cell single molecule fluorescence imaging

    Full text link
    Messenger RNAs (mRNAs) convey genetic information from the DNA genome to proteins and thus lie at the heart of gene expression and regulation of all cellular activities. Live cell single molecule tracking tools enable the investigation of mRNA trafficking, translation and degradation within the complex environment of the cell and in real time. Over the last 5 years, nearly all tools within the mRNA tracking toolbox have been improved to achieve high‐quality multi‐color tracking in live cells. For example, the bacteriophage‐derived MS2‐MCP system has been improved to facilitate cloning and achieve better signal‐to‐noise ratio, while the newer PP7‐PCP system now allows for orthogonal tracking of a second mRNA or mRNA region. The coming of age of epitope‐tagging technologies, such as the SunTag, MoonTag and Frankenbody, enables monitoring the translation of single mRNA molecules. Furthermore, the portfolio of fluorogenic RNA aptamers has been expanded to improve cellular stability and achieve a higher fluorescence “turn‐on” signal upon fluorogen binding. Finally, microinjection‐based tools have been shown to be able to track multiple RNAs with only small fluorescent appendages and to track mRNAs together with their interacting partners. We systematically review and compare the advantages, disadvantages and demonstrated applications in discovering new RNA biology of this refined, expanding toolbox. Finally, we discuss developments expected in the near future based on the limitations of the current methods.This article is categorized under:RNA Export and Localization > RNA LocalizationRNA Structure and Dynamics > RNA Structure, Dynamics, and ChemistryRNA Interactions with Proteins and Other Molecules > RNA–Protein ComplexesTools for the intracellular visualization of mRNA metabolism and function.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/155943/1/wrna1587_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/155943/2/wrna1587.pd

    De-fine: Decomposing and Refining Visual Programs with Auto-Feedback

    Full text link
    Visual programming, a modular and generalizable paradigm, integrates different modules and Python operators to solve various vision-language tasks. Unlike end-to-end models that need task-specific data, it advances in performing visual processing and reasoning in an unsupervised manner. Current visual programming methods generate programs in a single pass for each task where the ability to evaluate and optimize based on feedback, unfortunately, is lacking, which consequentially limits their effectiveness for complex, multi-step problems. Drawing inspiration from benders decomposition, we introduce De-fine, a general framework that automatically decomposes complex tasks into simpler subtasks and refines programs through auto-feedback. This model-agnostic approach can improve logical reasoning performance by integrating the strengths of multiple models. Our experiments across various visual tasks show that De-fine creates more accurate and robust programs, setting new benchmarks in the field

    Highly magnetic iron carbide nanoparticles as effective T2 contrast agents

    Get PDF
    This paper reports that iron carbide nanoparticles with high air-stability and strong saturation magnetization can serve as effective T2 contrast agents for magnetic resonance imaging. Fe5C2 nanoparticles (20 nm in diameter) exhibit strong contrast enhancement with an r2 value of 283.2 mM-1 S-1, which is about twice as high as that of spherical Fe3O4 nanoparticles (140.9 mM-1 S-1). In vivo experiments demonstrate that Fe5C2 nanoparticles are able to produce much more significant MRI contrast enhancement than conventional Fe3O 4 nanoparticles in living subjects, which holds great promise in biomedical applications. ? 2013 The Royal Society of Chemistry

    Highly magnetic iron carbide nanoparticles as effective T-2 contrast agents

    Get PDF
    National Key Basic Research Program of China [2013CB933901, 2014CB744502]; National Natural Science Foundation of China [21222106, 81370042, 81000662, 81201805]; Natural Science Foundation of Fujian [2013J06005]; Program for New Century Excellent Talents in University [NCET-10-0709]This paper reports that iron carbide nanoparticles with high air-stability and strong saturation magnetization can serve as effective T-2 contrast agents for magnetic resonance imaging. Fe5C2 nanoparticles (similar to 20 nm in diameter) exhibit strong contrast enhancement with an r(2) value of 283.2 mM(-1) S-1, which is about twice as high as that of spherical Fe3O4 nanoparticles (similar to 140.9 mM(-1) S-1). In vivo experiments demonstrate that Fe5C2 nanoparticles are able to produce much more significant MRI contrast enhancement than conventional Fe3O4 nanoparticles in living subjects, which holds great promise in biomedical applications

    Acute myocardial infarction after inactivated COVID-19 vaccination: a case report and literature review

    Get PDF
    A number of vaccines have been developed and deployed globally to restrain the spreading of the coronavirus disease 2019 (COVID-19). The adverse effect following vaccination is an important consideration. Acute myocardial infarction (AMI) is a kind of rare adverse event after COVID-19 vaccination. Herein, we present a case of an 83-year-old male who suffered cold sweat ten minutes after the first inactivated COVID-19 vaccination and AMI one day later. The emergency coronary angiography showed coronary thrombosis and underlying stenosis in his coronary artery. Type II Kounis syndrome might be a potential mechanism, which is manifested as coronary thrombosis secondary to allergic reactions in patients with underlying asymptomatic coronary heart disease. We also summarize the reported AMI cases post COVID-19 vaccination, as well as overview and discuss the proposed mechanisms of AMI after COVID-19 vaccination, thus providing insights for clinicians to be aware of the possibility of AMI following COVID-19 vaccination and potential underlying mechanisms

    Non-invasive Amide Proton Transfer Imaging and ZOOM Diffusion-Weighted Imaging in Differentiating Benign and Malignant Thyroid Micronodules

    Get PDF
    Background: Pre-operative non-invasive differentiation of benign and malignant thyroid nodules is difficult for doctors. This study aims to determine whether amide proton transfer (APT) imaging and zonally oblique multi-slice (ZOOM) diffusion-weighted imaging (DWI) can provide increased accuracy in differentiating benign and malignant thyroid nodules.Methods: This retrospective study was approved by the institutional review board and included 60 thyroid nodules in 50 patients. All of the nodules were classified as malignant (n = 21) or benign (n = 39) based on pathology. It was meaningful to analyze the APT and apparent diffusion coefficient (ADC) values of the two groups by independent t-test to identify the benign and malignant thyroid nodules. The relationship between APT and ZOOM DWI was explored through Pearson correlation analysis. The diagnostic efficacy of APT and ZOOM DWI in determining if thyroid nodules were benign or malignant was compared using receiver operating characteristic (ROC) curve analysis.Results: The mean APTw value of the benign nodules was 2.99 ± 0.79, while that of the malignant nodules was 2.14 ± 0.73. Additionally, there was a significant difference in the APTw values of the two groups (P < 0.05). The mean ADC value of the benign nodules was 1.84 ± 0.41, and was significantly different from that of the malignant nodules, which was 1.21 ± 0.19 (P < 0.05). Scatter point and Pearson test showed a moderate positive correlation between the APT and ADC values (P < 0.05). The ROC curve showed that the area under the curve (AUC) value of ZOOM DWI (AUC = 0.937) was greater than that of APT (AUC = 0.783) (P = 0.028).Conclusion: APT and ZOOM DWI imaging improved the accuracy of distinguishing between benign and malignant thyroid nodules. ZOOM DWI is superior to APTw imaging (Z = 2.198, P < 0.05)

    Tembusu Virus in Ducks, China

    Get PDF
    In China in 2010, a disease outbreak in egg-laying ducks was associated with a flavivirus. The virus was isolated and partially sequenced. The isolate exhibited 87%–91% identity with strains of Tembusu virus, a mosquito-borne flavivirus of the Ntaya virus group. These findings demonstrate emergence of Tembusu virus in ducks

    Real-time Monitoring for the Next Core-Collapse Supernova in JUNO

    Full text link
    Core-collapse supernova (CCSN) is one of the most energetic astrophysical events in the Universe. The early and prompt detection of neutrinos before (pre-SN) and during the SN burst is a unique opportunity to realize the multi-messenger observation of the CCSN events. In this work, we describe the monitoring concept and present the sensitivity of the system to the pre-SN and SN neutrinos at the Jiangmen Underground Neutrino Observatory (JUNO), which is a 20 kton liquid scintillator detector under construction in South China. The real-time monitoring system is designed with both the prompt monitors on the electronic board and online monitors at the data acquisition stage, in order to ensure both the alert speed and alert coverage of progenitor stars. By assuming a false alert rate of 1 per year, this monitoring system can be sensitive to the pre-SN neutrinos up to the distance of about 1.6 (0.9) kpc and SN neutrinos up to about 370 (360) kpc for a progenitor mass of 30M⊙M_{\odot} for the case of normal (inverted) mass ordering. The pointing ability of the CCSN is evaluated by using the accumulated event anisotropy of the inverse beta decay interactions from pre-SN or SN neutrinos, which, along with the early alert, can play important roles for the followup multi-messenger observations of the next Galactic or nearby extragalactic CCSN.Comment: 24 pages, 9 figure
    • 

    corecore