73 research outputs found

    Endovascular Treatment of Intracranial Vein and Venous Sinus Thrombosis-A Systematic Review.

    Get PDF
    BACKGROUND Cerebral venous sinus or vein thromboses (SVT) are treated with heparin followed by oral anticoagulation. Even after receiving the best medical treatment, numerous patients experience neurological deterioration, intracerebral hemorrhage or brain edema. Debate regarding whether endovascular treatment (EVT) is beneficial in such severe cases remains ongoing. This systematic review summarizes the current evidence supporting the use of EVT for SVT on the basis of case presentations, with a focus on patient selection, treatment strategies and the effects of the COVID-19 pandemic. METHODS This systemic literature review included randomized controlled trials (RCTs) and retrospective observational data analyzing five or more patients. Follow-up information (modified Rankin scale (mRS)) was required to be provided (individual patient data). RESULTS 21 records (n = 405 patients; 1 RCT, 20 observational studies) were identified. EVT was found to be feasible and safe in a highly selected patient cohort but was not associated with an increase in good functional outcomes (mRS 0-2) in RCT data. In observational data, good functional outcomes were frequently observed despite an anticipated poor prognosis. CONCLUSION The current evidence does not support the routine incorporation of EVT in SVT treatment. However, in a patient cohort prone to poor prognosis, EVT might be a reasonable therapeutic option. Further studies determining the patients at risk, choice of methods and devices, and timing of treatment initiation are warranted

    Histogram Analysis of Diffusion Weighted Imaging in Low-Grade Gliomas: in vivo Characterization of Tumor Architecture and Corresponding Neuropathology

    Get PDF
    Background: Low-grade gliomas (LGG) in adults are usually slow growing and frequently asymptomatic brain tumors, originating from glial cells of the central nervous system (CNS). Although regarded formally as “benign” neoplasms, they harbor the potential of malignant transformation associated with high morbidity and mortality. Their complex and unpredictable tumor biology requires a reliable and conclusive presurgical magnetic resonance imaging (MRI). A promising and emerging MRI approach in this context is histogram based apparent diffusion coefficient (ADC) profiling, which recently proofed to be capable of providing prognostic relevant information in different tumor entities. Therefore, our study investigated whether histogram profiling of ADC distinguishes grade I from grade II glioma, reflects the proliferation index Ki-67, as well as the IDH (isocitrate dehydrogenase) mutation and MGMT (methylguanine-DNA methyl-transferase) promotor methylation status. Material and Methods: Pre-treatment ADC volumes of 26 LGG patients were used for histogram-profiling. WHO-grade, Ki-67 expression, IDH mutation, and MGMT promotor methylation status were evaluated. Comparative and correlative statistics investigating the association between histogram-profiling and neuropathology were performed. Results: Almost the entire ADC profile (p25, p75, p90, mean, median) was significantly lower in grade II vs. grade I gliomas. Entropy, as second order histogram parameter of ADC volumes, was significantly higher in grade II gliomas compared with grade I gliomas. Mean, maximum value (ADCmax) and the percentiles p10, p75, and p90 of ADC histogram were significantly correlated with Ki-67 expression. Furthermore, minimum ADC value (ADCmin) was significantly associated with MGMT promotor methylation status as well as ADC entropy with IDH-1 mutation status. Conclusions: ADC histogram-profiling is a valuable radiomic approach, which helps differentiating tumor grade, estimating growth kinetics and probably prognostic relevant genetic as well as epigenetic alterations in LGG

    The Combined Use of Intraluminal and Intrasaccular Flow Diversion for the Treatment of Intracranial Aneurysms: Report of 25 Cases

    Get PDF
    PurposeThe Medina Embolic Device (MED) is a new intrasaccular device with promising early results. Previously we documented our initial experience of this device both alone and in combination with other devices including flow diverter stents (FDS). We sought to determine the effect of the MED + FDS strategy for the treatment of selected aneurysms.Materials and MethodsWe performed a retrospective analysis of prospectively collected data to identify all patients with aneurysms treated using both the MED and intraluminal FDS. We present our technical success rate, early and mid-term angiographic follow-up, and clinical outcome data.ResultsWe identified 25 non-consecutive patients. The treatment was staged in 9 patients and in a single session 16 patients. The average age was 61±12.8 years (range 40–82). The average fundus height was 11±3.6 mm and average fundus width was 10.1±3.4 mm. In the staged cohort (n=9) at delayed angiography (mean 10 mths) 8 aneurysms (89%) showed complete exclusion (mRRC 1) and in one patient there was a parent vessel occlusion. In the simultaneous cohort delayed angiography (n=10, mean 8.1 months) demonstrated complete occlusion (mRRC 1) in 6 aneurysms (60%), 3 neck remnants (mRRC 2) (30%) and 1 patient (10%) showed persistent aneurysmal filling (mRRC 3a). There were 5 complications with permanent morbidity (mRS >2) in two patients. There were no mortalities.ConclusionThe MED can be successfully used in combination with intraluminal FDS and in selected aneurysms this may represent an alternative to FDS and adjunctive coiling

    Opportunities and Alternatives of Modern Radiation Oncology and Surgery for the Management of Resectable Brain Metastases.

    Get PDF
    Postsurgical radiotherapy (RT) has been early proven to prevent local tumor recurrence, initially performed with whole brain RT (WBRT). Subsequent to disadvantageous cognitive sequalae for the patient and the broad distribution of modern linear accelerators, focal irradiation of the tumor has omitted WBRT in most cases. In many studies, the effectiveness of local RT of the resection cavity, either as single-fraction stereotactic radiosurgery (SRS) or hypo-fractionated stereotactic RT (hFSRT), has been demonstrated to be effective and safe. However, whereas prospective high-level incidence is still lacking on which dose and fractionation scheme is the best choice for the patient, further ablative techniques have come into play. Neoadjuvant SRS (N-SRS) prior to resection combines straightforward target delineation with an accelerated post-surgical phase, allowing an earlier start of systemic treatment or rehabilitation as indicated. In addition, low-energy intraoperative RT (IORT) on the surgical bed has been introduced as another alternative to external beam RT, offering sterilization of the cavity surface with steep dose gradients towards the healthy brain. This consensus paper summarizes current local treatment strategies for resectable brain metastases regarding available data and patient-centered decision-making

    Diagnostic reliability of the Berlin classification for complex MCA aneurysms—usability in a series of only giant aneurysms

    Get PDF
    Background and objective The main challenge of bypass surgery of complex MCA aneurysms is not the selection of the bypass type but the initial decision-making of how to exclude the affected vessel segment from circulation. To this end, we have previously proposed a classification for complex MCA aneurysms based on the preoperative angiography. The current study aimed to validate this new classification and assess its diagnostic reliability using the giant aneurysm registry as an independent data set. Methods We reviewed the pretreatment neuroimaging of 51 patients with giant (> 2.5 cm) MCA aneurysms from 18 centers, prospectively entered into the international giant aneurysm registry. We classified the aneurysms according to our previously proposed Berlin classification for complex MCA aneurysms. To test for interrater diagnostic reliability, the data set was reviewed by four independent observers. Results We were able to classify all 51 aneurysms according to the Berlin classification for complex MCA aneurysms. Eight percent of the aneurysm were classified as type 1a, 14% as type 1b, 14% as type 2a, 24% as type 2b, 33% as type 2c, and 8% as type 3. The interrater reliability was moderate with Fleiss's Kappa of 0.419. Conclusion The recently published Berlin classification for complex MCA aneurysms showed diagnostic reliability, independent of the observer when applied to the MCA aneurysms of the international giant aneurysm registry.Peer reviewe

    Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use

    No full text
    Streamline representation of major fiber tract systems along with high-resolution anatomical data provides a reliable orientation for the neurosurgeon. For direct visualization of these data in the surgical field applying heads-up displays of operating microscopes, wrapping of all streamlines of interest to render an individual object representing the whole fiber bundle is mandatory. Integration of fiber tract data into a neuronavigation setup allows removal of tumors adjacent to eloquent brain areas with low morbidity

    Application Accuracy of Automatic Registration in Frameless Stereotaxy

    No full text
    Objective: We compared the application accuracy of an infrared- based neuronavigation system when used with a novel automatic registration with its application accuracy when standard fiducial-based registration is performed. Methods: The automatic referencing tool is based on markers that are integrated in the headrest holder we routinely use in our intraoperative magnetic resonance imaging (MRI) setting and can be detected by the navigation software automatically. For navigation targeting we used a Plexiglas phantom with 32 notched rods of different heights. The phantom was fixed in the head holder and multiple optimized gradient echo slices containing the clamp-integrated markers were acquired. After that we measured a T 1 MPRAGE sequence with a slice thickness of 1.0 mm for navigation. The deepest points of the surface of the rods were defined as target points in image space. In three measurement series we referenced the phantom once with 4, once with 7 fiducials and twice automatically. In one series we performed only one automatic registration. The localization error was measured 3 times per rod and registration. Results: The median localization errors for standard registration with 7 fiducials were between 1.2 and 3.05 mm. With 4 fiducials, me- dians were in the range from 1.87 to 2.21 mm. For the automatic registration we obtained median localization errors between 0.88 and 2.13 mm. In 6 of the 8 samples that were compared the automatic registration showed an application accuracy that was highly significantly better (p ! 0.001 in most cases) than that of fiducial-based standard registration. Conclusion: The application accuracy found for automatic referencing is at least not worse than that for standard registration no matter whether 4 or 7 fiducial markers were used. Therefore, its use in the operating room is feasible. In combination with intraoperative MRI it may become a favorable alternative to standard fiducial-based registration especially when an intraoperative update of navigation data is necessary
    corecore