97 research outputs found

    The Italian contribution to the construction of the linac for the European spallation source

    Get PDF
    AbstractThe European spallation source (ESS) uses a linear accelerator (linac) to deliver the high intensity proton beam to the target station for producing intense beams of neutrons. At the exit of the linac, the proton beam will have 2 GeV energy and 62.5 mA current. The construction of an accelerator with the contribution of different laboratories is not a new concept but so far the laboratories were controlled by the same government (e.g. in USA and Japan) or they delivered components for an intergovernmental institution like CERN. The European Spallation Source is a research facility that gathers 40 active in-kind (IK) contributors from 13 States, even outside the European Union, so its construction is not only a technical and scientific challenge, but also an economic, political and social experiment. The case of the Italian contribution is interesting because of the structure of Italian industrial ecosystem, mostly based on small and medium-sized enterprises (SME), which may be unsuitable for the case of a research infrastructure which construction requires a high level of R&D investments. Conversely, the well-known flexibility of SME to adapt to the requirements have balanced the weakness and the results are satisfactory. Following the overview of the Linac design, the paper will focus on the key issues of the Italian contribution, the state of the project (73% completion up to now) along with the point of view of the ESS management and the lesson learnt; the major outcomes for the economy and society will complete the discussion

    Rapid One-Step Fabrication of Graphene Oxide-Decorated Polycaprolactone Three-Dimensional Templates for Water Treatment

    Get PDF
    Coating of flexible substrates is crucial to prepare versatile, multifunctional materials. However, exploration of effective fabrication approaches is still a challenging issue, because the pathways generally proposed require time-consuming, multistep protocols. Here, we developed a one-pot process for decorating either pearl necklace-like or fibrous fluffy-like structures of polycaprolactone (PCL) with graphene oxide (GO) skin. PCL solutions were dry jet-wet electrosprayed or electrospun into a stirred liquid collector constituted by ethanol-containing GO nanoparticles. The stirred liquid collector enables the formation of 3D-structures, whose microarchitecture can be designed by controlling the rheological behavior of PCL solutions. Two molecular weights of PCL were used (45 or 80 kDa) with ensuing different viscosity, which determines the prevalent formation of beads or fibers. The presence of GO in the coagulation bath allows the polymeric structures to be rapidly wrapped by those nanoparticles. Graphenic coating endows these materials with the intriguing peculiarities of GO: PCL/GO nanocomposites displayed increments of elastic modulus ranging from 1250% (beads) to 3300% (fibers) with respect to the neat matrices and a change from hydrophobic to amphiphilic character. A potential application of such devices in water treatment was assessed in phenol removal. The results pointed out that PCL/GO scaffolds retain the same sorption capacity of GO nanoparticles, while bringing several advantages in terms of handling, robustness, and recyclability. The ease of control of the process, as well as its fastness and cost-effectiveness could open a wide range of scenarios, including sensors, energy, catalysis, biomedicine

    Validity and reliability of an inertial sensor device for specific running patterns in soccer

    Get PDF
    Electronic performance tracking devices are largely employed in team sports to monitor performance and improve training. To date, global positioning system (GPS) based devices are those mainly used in soccer training. The aim of this study was to analyse the validity and reliability of the inertial sensor device (ISD) in monitoring distance and speed in a soccer-specific circuit and how their performance compare to a GPS system. 44 young male soccer players (age: 14.9 ± 1.1, range 9– 16, years, height: 1.65 ± 0.10 m, body mass: 56.3 ± 8.9 kg) playing in a non-professional soccer team in Italy, participated in the study. We assessed the players trough a soccer running sport-specific circuit. An ISD and a GPS were used to assess distance and speed. Data was compared to a video reference system, and the difference were quantified by means of the root mean square error (RMSE). Significant differences were found for both GPS and ISD devices for distance and speed. However, lower error for distance (dRMSE 2.23 ± 1.01 m and 5.75 ± 1.50 m, respectively) and speed (sRMSE 0.588 ± 0.152 m*s–1 and 1.30 ± 0.422 m*s–1, respectively) were attained by the ISD compared to the GPS. Overall, our results revealed a statistically significant difference between systems in data monitoring for either distance and speed. However, results of this study showed that a smaller error was obtained with the ISD than the GPS device. Despite caution is warranted within the interpreta-tion of these results, we observed a better practical applicability of the ISD due to its small size, lower cost and the possibility to use the device indoor

    Production of intense highly charged ion beams with SERSE

    Get PDF
    The source SERSE is operational at LNS since June 1998 and many improvements have been carried out in this period. The frequency has been increased from 14.5 GHz to 18 GHz and the use of two frequency heating has given positive results. Metallic ion production has been tested by means of a high temperature oven and the preliminary results are described. Tests of magnetic field scaling and frequency scaling have confirmed the results of previous tests with SC-ECRIS at lower frequency and seems to suggest that the upgrading of the source to higher frequency may be considered

    Summary of the performances of the superconducting electron cyclotron resonance ion source at 14 GHz

    Get PDF
    This article deals with the most recent performance of the superconducting electron cyclotron resonance ion source (SERSE) working at 14 GHz with high magnetic fields after the required conditioning and optimization of several operating parameters. SERSE has now achieved an outstanding level of performance in delivering highly charged ion beams in argon and oxygen gases: the results obtained while operating in a stainless steel chamber and with an aluminum liner are shown and discussed

    A TM01 mode launcher with quadrupole field components cancellation for high brightness applications

    Get PDF
    The R&D of high gradient radiofrequency (RF) devices is aimed to develop innovative accelerating structures based on new manufacturing techniques and materials in order to construct devices operating with the highest accelerating gradient. Recent studies have shown a large increase in the maximum sustained RF surface electric fields in copper structures operating at cryogenic temperatures. These novel approaches allow significant performance improvements of RF photoinjectors. Indeed the operation at high surface fields results in considerable increase of electron beam brilliance. This increased brilliance requires high field quality in the RF photoinjector and specifically in its power coupler. In this work we present a novel power coupler for the RF photoinjector. The coupler is a compact X-band TM01 mode launcher with a fourfold symmetry which minimized both the dipole and the quadrupole RF components

    A public early intervention approach to first-episode psychosis: Treated incidence over 7 years in the Emilia-Romagna region

    Get PDF
    AimTo estimate the treated incidence of individuals with first-episode psychosis (FEP) who contacted the Emilia-Romagna public mental healthcare system (Italy); to examine the variability of incidence and user characteristics across centres and years. MethodsWe computed the raw treated incidence in 2013-2019, based on FEP users aged 18-35, seen within or outside the regional program for FEP. We modelled FEP incidence across 10 catchment areas and 7 years using Bayesian Poisson and Negative Binomial Generalized Linear Models of varying complexity. We explored associations between user characteristics, study centre and year comparing variables and socioclinical clusters of subjects. ResultsThousand three hundred and eighteen individuals were treated for FEP (raw incidence: 25.3 / 100.000 inhabitant year, IQR: 15.3). A Negative Binomial location-scale model with area, population density and year as predictors found that incidence and its variability changed across centres (Bologna: 36.55; 95% CrI: 30.39-43.86; Imola: 3.07; 95% CrI: 1.61-4.99) but did not follow linear temporal trends or density. Centers were associated with different user age, gender, migrant status, occupation, living conditions and cluster distribution. Year was associated negatively with HoNOS score (R = -0.09, p < .001), duration of untreated psychosis (R = -0.12, p < .001) and referral type. ConclusionsThe Emilia-Romagna region presents a relatively high but variable incidence of FEP across areas, but not in time. More granular information on social, ethnic and cultural factors may increase the level of explanation and prediction of FEP incidence and characteristics, shedding light on social and healthcare factors influencing FEP
    • …
    corecore