67 research outputs found
Alcuni cenni sul sistema di consonanze e differenze tra Benjamin e Adorno
This article proposes an analysis of the most relevant differences between the two Germans philosophers, Walter Benjamin and Theodor Adorno.It seems that the roots of all the divergences between the two philosophers is in a different use of the dialectic. For Adorno, in facts, the dialectic is a way through which you can always show the other side, the opposite, inside every analyzed phenomenon, risking sometimes to become abstracted from the historic moment in question. For Benjamin, the dialectic will be instead that movement to apply, starting from and inside the contemporary historical moment, because this gives relevance every time to a certain phenomenon instead of others. The goal will be a dialogue with an infernal present and, once we have found out a way to escape it’s possible to set free from it. It will be remarked, how, from a different dialectic conception corresponds to a different way to look at the aesthetic, its foundations and its citizen's right in the modernity.In conclusion, some connecting lines are traced with the contemporaneity, that involve the actuality of the thought of the two Germans thinkers as well as the ability of being ahead of their time and give other development to their investigations
High Risk of Secondary Infections Following Thrombotic Complications in Patients With COVID-19
Background. This study’s primary aim was to evaluate the impact of thrombotic complications on the development of secondary infections. The secondary aim was to compare the etiology of secondary infections in patients with and without thrombotic complications. Methods. This was a cohort study (NCT04318366) of coronavirus disease 2019 (COVID-19) patients hospitalized at IRCCS San Raffaele Hospital between February 25 and June 30, 2020. Incidence rates (IRs) were calculated by univariable Poisson regression as the number of cases per 1000 person-days of follow-up (PDFU) with 95% confidence intervals. The cumulative incidence functions of secondary infections according to thrombotic complications were compared with Gray’s method accounting for competing risk of death. A multivariable Fine-Gray model was applied to assess factors associated with risk of secondary infections. Results. Overall, 109/904 patients had 176 secondary infections (IR, 10.0; 95% CI, 8.8–11.5; per 1000-PDFU). The IRs of secondary infections among patients with or without thrombotic complications were 15.0 (95% CI, 10.7–21.0) and 9.3 (95% CI, 7.9–11.0) per 1000-PDFU, respectively (P = .017). At multivariable analysis, thrombotic complications were associated with the development of secondary infections (subdistribution hazard ratio, 1.788; 95% CI, 1.018–3.140; P = .043). The etiology of secondary infections was similar in patients with and without thrombotic complications. Conclusions. In patients with COVID-19, thrombotic complications were associated with a high risk of secondary infections
Study of cosmogenic activation above ground for the DarkSide-20k experiment
The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39Ar. Despite the outstanding capability of discriminating
/
background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37Ar and 3H are shown not to be relevant due to short half-life and assumed purification methods
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Dark matter lighter than 10  GeV/c2 encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino fog for GeV-scale masses and significant sensitivity down to 10  MeV/c2 considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector’s sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies
Study on cosmogenic activation above ground for the DarkSide-20k project
The activation of materials due to the exposure to cosmic rays may become an
important background source for experiments investigating rare event phenomena.
DarkSide-20k is a direct detection experiment for galactic dark matter
particles, using a two-phase liquid argon time projection chamber filled with
49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39Ar. Here,
the cosmogenic activity of relevant long-lived radioisotopes induced in the
argon and other massive components of the set-up has been estimated; production
of 120 t of radiopure UAr is foreseen. The expected exposure above ground and
production rates, either measured or calculated, have been considered. From the
simulated counting rates in the detector due to cosmogenic isotopes, it is
concluded that activation in copper and stainless steel is not problematic.
Activation of titanium, considered in early designs but not used in the final
design, is discussed. The activity of 39Ar induced during extraction,
purification and transport on surface, in baseline conditions, is evaluated to
be 2.8% of the activity measured in UAr from the same source, and thus
considered acceptable. Other products in the UAr such as 37Ar and 3H are shown
to not be relevant due to short half-life and assumed purification methods
Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches
The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: 36Ar , 38Ar , and 40Ar . We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019
Directionality of nuclear recoils in a liquid argon time projection chamber
The direct search for dark matter in the form of weakly interacting massive
particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a
target material from the WIMP elastic scattering. A promising experimental
strategy for direct dark matter search employs argon dual-phase time projection
chambers (TPC). One of the advantages of the TPC is the capability to detect
both the scintillation and charge signals produced by NRs. Furthermore, the
existence of a drift electric field in the TPC breaks the rotational symmetry:
the angle between the drift field and the momentum of the recoiling nucleus can
potentially affect the charge recombination probability in liquid argon and
then the relative balance between the two signal channels. This fact could make
the detector sensitive to the directionality of the WIMP-induced signal,
enabling unmistakable annual and daily modulation signatures for future
searches aiming for discovery. The Recoil Directionality (ReD) experiment was
designed to probe for such directional sensitivity. The TPC of ReD was
irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data
were taken with 72 keV NRs of known recoil directions. The direction-dependent
liquid argon charge recombination model by Cataudella et al. was adopted and a
likelihood statistical analysis was performed, which gave no indications of
significant dependence of the detector response to the recoil direction. The
aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/-
0.027 and the upper limit is R < 1.072 with 90% confidence levelComment: 20 pages, 10 figures, submitted to Eur. Phys. J.
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Dark matter lighter than 10 GeV/c encompasses a promising range of
candidates. A conceptual design for a new detector, DarkSide-LowMass, is
presented, based on the DarkSide-50 detector and progress toward DarkSide-20k,
optimized for a low-threshold electron-counting measurement. Sensitivity to
light dark matter is explored for various potential energy thresholds and
background rates. These studies show that DarkSide-LowMass can achieve
sensitivity to light dark matter down to the solar neutrino floor for GeV-scale
masses and significant sensitivity down to 10 MeV/c considering the Migdal
effect or interactions with electrons. Requirements for optimizing the
detector's sensitivity are explored, as are potential sensitivity gains from
modeling and mitigating spurious electron backgrounds that may dominate the
signal at the lowest energies
- …