1,735 research outputs found
Young women's use of a microbicide surrogate: The complex influence of relationship characteristics and perceived male partners' evaluations
This is the post-print version of the article. The official published version can be found at the link below.Currently in clinical trials, vaginal microbicides are proposed as a female-initiated method of sexually transmitted infection prevention. Much of microbicide acceptability research has been conducted outside of the United States and frequently without consideration of the social interaction between sex partners, ignoring the complex gender and power structures often inherent in young women’s (heterosexual) relationships. Accordingly, the purpose of this study was to build on existing microbicide research by exploring the role of male partners and relationship characteristics on young women’s use of a microbicide surrogate, an inert vaginal moisturizer (VM), in a large city in the United States. Individual semi-structured interviews were conducted with 40 young women (18–23 years old; 85% African American; 47.5% mothers) following use of the VM during coital events for a 4 week period. Overall, the results indicated that relationship dynamics and perceptions of male partners influenced VM evaluation. These two factors suggest that relationship context will need to be considered in the promotion of vaginal microbicides. The findings offer insights into how future acceptability and use of microbicides will be influenced by gendered power dynamics. The results also underscore the importance of incorporating men into microbicide promotion efforts while encouraging a dialogue that focuses attention on power inequities that can exist in heterosexual relationships. Detailed understanding of these issues is essential for successful microbicide acceptability, social marketing, education, and use.This study was funded by a grant from National Institutes of Health (NIHU19AI 31494) as well as research awards to the first author: Friends of the Kinsey Institute Research Grant Award, Indiana University’s School of HPER Graduate Student Grant-in-Aid of Research Award, William L. Yarber Sexual Health Fellowship, and the Indiana University Graduate and Professional Student Organization Research Grant
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.Comment: 16 pages, 16 figure
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry
A Search for Neutrinos from the Solar hep Reaction and the Diffuse Supernova Neutrino Background with the Sudbury Neutrino Observatory
A search has been made for neutrinos from the hep reaction in the Sun and from the diffus
Low Multiplicity Burst Search at the Sudbury Neutrino Observatory
Results are reported from a search for low-multiplicity neutrino bursts in
the Sudbury Neutrino Observatory (SNO). Such bursts could indicate detection of
a nearby core-collapse supernova explosion. The data were taken from Phase I
(November 1999 - May 2001), when the detector was filled with heavy water, and
Phase II (July 2001 - August 2003), when NaCl was added to the target. The
search was a blind analysis in which the potential backgrounds were estimated
and analysis cuts were developed to eliminate such backgrounds with 90%
confidence before the data were examined. The search maintained a greater than
50% detection probability for standard supernovae occurring at a distance of up
to 60 kpc for Phase I and up to 70 kpc for Phase II. No low-multiplicity bursts
were observed during the data-taking period.Comment: 11 pages, 4 figures, submitted to Ap
Recommended from our members
Searches For High-Frequency Variations In The B-8 Solar Neutrino Flux At The Sudbury Neutrino Observatory
We have performed three searches for high-frequency signals in the solar neutrino flux measured by the Sudbury Neutrino Observatory, motivated by the possibility that solar g-mode oscillations could affect the production or propagation of solar B-8 neutrinos. The first search looked for any significant peak in the frequency range 1-144 day(-1), with a sensitivity to sinusoidal signals with amplitudes of 12% or greater. The second search focused on regions in which g-mode signals have been claimed by experiments aboard the Solar and Heliospheric Observatory satellite, and was sensitive to signals with amplitudes of 10% or greater. The third search looked for extra power across the entire frequency band. No statistically significant signal was detected in any of the three searches.Natural Sciences and Engineering Research Council, CanadaIndustry Canada, CanadaNational Research Council, CanadaNorthern Ontario Heritage Fund, CanadaAtomic Energy of Canada, Ltd., CanadaOntario Power Generation, CanadaHigh Performance Computing Virtual Laboratory, CanadaCanada Foundation for InnovationDept. of Energy, USNational Energy Research Scientific Computing Center, USScience and Technologies Facilities Council, UKAstronom
Measurement of triple gauge boson couplings from W⁺W⁻ production at LEP energies up to 189 GeV
A measurement of triple gauge boson couplings is presented, based on W-pair data recorded by the OPAL detector at LEP during 1998 at a centre-of-mass energy of 189 GeV with an integrated luminosity of 183 pb⁻¹. After combining with our previous measurements at centre-of-mass energies of 161–183 GeV we obtain κ = 0.97_{-0.16}^{+0.20}, g_{1}^{z} = 0.991_{-0.057}^{+0.060} and λ = -0.110_{-0.055}^{+0.058}, where the errors include both statistical and systematic uncertainties and each coupling is determined by setting the other two couplings to their Standard Model values. These results are consistent with the Standard Model expectations
Measurement of the Total Active 8B Solar Neutrino Flux at the Sudbury Neutrino Observatory with Enhanced Neutral Current Sensitivity
The Sudbury Neutrino Observatory (SNO) has precisely determined the total
active (nu_x) 8B solar neutrino flux without assumptions about the energy
dependence of the nu_e survival probability. The measurements were made with
dissolved NaCl in the heavy water to enhance the sensitivity and signature for
neutral-current interactions. The flux is found to be 5.21 +/- 0.27 (stat) +/-
0.38 (syst) x10^6 cm^{-2}s^{-1}, in agreement with previous measurements and
standard solar models. A global analysis of these and other solar and reactor
neutrino results yields Delta m^{2} = 7.1^{+1.2}_{-0.6}x10^{-5} ev^2 and theta
= 32.5^{+2.4}_{-2.3} degrees. Maximal mixing is rejected at the equivalent of
5.4 standard deviations.Comment: Submitted to Phys. Rev. Let
- …