791 research outputs found
A Fully Parameterized Fem Model for Electromagnetic Optimization of an RF Mems Wafer Level Package
In this work, we present a fully parameterized capped transmission line model
for electromagnetic optimization of a wafer level package (WLP) for RF MEMS
applications using the Ansoft HFSS-TM electromagnetic simulator. All the
degrees of freedom (DoF's) in the package fabrication can be modified within
the model in order to optimize for losses and mismatch (capacitive and
inductive couplings) introduced by the cap affecting the MEMS RF behaviour.
Ansoft HFSS-TM was also validated for the simulation of capped RF MEMS devices
by comparison against experimental data. A test run of capped 50 transmission
lines and shorts was fabricated and tested.Comment: Submitted on behalf of EDA Publishing Association
(http://irevues.inist.fr/EDA-Publishing
Parasitic Effects Reduction for Wafer-Level Packaging of RF-Mems
In RF-MEMS packaging, next to the protection of movable structures,
optimization of package electrical performance plays a very important role. In
this work, a wafer-level packaging process has been investigated and optimized
in order to minimize electrical parasitic effects. The RF-MEMS package concept
used is based on a wafer-level bonding of a capping silicon substrate to an
RF-MEMS wafer. The capping silicon substrate resistivity, substrate thickness
and the geometry of through-substrate electrical interconnect vias have been
optimized using finite-element electromagnetic simulations (Ansoft HFSS). Test
structures for electrical characterization have been designed and after their
fabrication, measurement results will be compared with simulations.Comment: Submitted on behalf of TIMA Editions
(http://irevues.inist.fr/tima-editions
Inference of FDI in Indian retail sector: Some Reflections
Purpose- The Indian retail market, which was largely unorganized till the 1980s, has undergone an immense transformation in post-liberalization era. However, valued at 315 billion (approx) in global sale. India is estimated to have around 15 million retail outlets, making it the country with the highest retail outlet density in the world. A.T. Kearney, a well known international management consultancy, in the year 2009, identified India as the most attractive retail destination in the world. With a significant contribution to the national GDP (10 percent) and employment (8 percent, second largest employer after agriculture) this sector can definitely be referred as one of the pillars of the Indian economy.
Design/methodology/approach- The paper pulls together various strains of research and data gathere from sound databases to discuss the status.
Findings- In their preparation to face fierce competitive pressure, Indian retailers must come to recognize the value of building their own stores as brands to reinforce their marketing Positioning, to communicate quality as well as value for money. Sustainable competitive advantage will be dependent on translating core values combining products, image and reputation into a coherent retail brand strategy.
Viewpoint
Reference to this paper should be made as follows: Deshpande, M., Gaddi, A., Patil, S. R. (2014). “Inference of FDI in Indian retail sector- Some Reflections”, Journal of Entrepreneurship, Business and Economics, Vol. 2, No. 2, pp. 82–97
Developing the Technique of Measurements of Magnetic Field in the CMS Steel Yoke Elements With Flux-Loops and Hall Probes
Compact muon solenoid (CMS) is a general-purpose detector designed to run at
the highest luminosity at the CERN large hadron collider (LHC). Its distinctive
features include a 4 T superconducting solenoid with 6 m diameter by 12.5 m
long free bore, enclosed inside a 10000-ton return yoke made of construction
steel. Accurate characterization of the magnetic field everywhere in
theCMSdetector, including the large ferromagnetic parts of the yoke, is
required. To measure the field in and around ferromagnetic parts, a set of
flux-loops and Hall probe sensors will be installed on several of the steel
pieces. Fast discharges of the solenoid during system commissioning tests will
be used to induce voltages in the flux-loops that can be integrated to measure
the flux in the steel at full excitation of the solenoid. The Hall sensors will
give supplementary information on the axial magnetic field and permit
estimation of the remanent field in the steel after the fast discharge. An
experimental R&D program has been undertaken, using a test flux-loop, two Hall
sensors, and sample disks made from the same construction steel used for the
CMS magnet yoke. A sample disc, assembled with the test flux-loop and the Hall
sensors, was inserted between the pole tips of a dipole electromagnet equipped
with a computer-controlled power supply to measure the excitation of the steel
from full saturation to zero field. The results of the measurements are
presented and discussed.Comment: 6 pages, 8 figures, 6 reference
Measuring the Magnetic Flux Density with Flux Loops and Hall Probes in the CMS Magnet Flux Return Yoke
The Compact Muon Solenoid (CMS) is a general purpose detector, designed to
run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its
distinctive features include a 4 T superconducting solenoid with 6-m-diameter
by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of
construction steel. The flux return yoke consists of five dodecagonal
three-layered barrel wheels and four end-cap disks at each end comprised of
steel blocks up to 620 mm thick, which serve as the absorber plates of the muon
detection system. To measure the field in and around the steel, a system of 22
flux loops and 82 3-D Hall sensors is installed on the return yoke blocks. A
TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field
everywhere outside the tracking volume that was measured with the field-mapping
machine. The voltages induced in the flux loops by the magnetic flux changing
during the CMS magnet standard ramps down are measured with six 16-bit DAQ
modules. The off-line integration of the induced voltages reconstructs the
magnetic flux density in the yoke steel blocks at the operational magnet
current of 18.164 kA. The results of the flux loop measurements during three
magnet ramps down are presented and discussed.Comment: 3 pages, 6 figures, presented at the IEEE Nuclear Science Symposium
2016 (NSS) in Strasbourg, France on November 3, 2016. arXiv admin note: text
overlap with arXiv:1605.0877
Flux Loop Measurements of the Magnetic Flux Density in the CMS Magnet Yoke
The Compact Muon Solenoid (CMS) is a general purpose detector, designed to
run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its
distinctive features include a 4 T superconducting solenoid with 6-m-diameter
by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of
construction steel. The return yoke consists of five dodecagonal three-layered
barrel wheels and four end-cap disks at each end comprised of steel blocks up
to 620 mm thick, which serve as the absorber plates of the muon detection
system. To measure the field in and around the steel, a system of 22 flux loops
and 82 3-D Hall sensors is installed on the return yoke blocks. A TOSCA 3-D
model of the CMS magnet is developed to describe the magnetic field everywhere
outside the tracking volume measured with the field-mapping machine. The first
attempt is made to measure the magnetic flux density in the steel blocks of the
CMS magnet yoke using the standard magnet discharge with the current ramp down
speed of 1.5 A/s.Comment: 7 pages, 5 figures, presented at ISCM2016 - 5th International
Conference on Superconductivity and Magnetism on April 28, 2016 at Fethiye,
Turke
Measuring the Magnetic Flux Density in the CMS Steel Yoke
The Compact Muon Solenoid (CMS) is a general purpose detector, designed to
run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its
distinctive features include a 4 T superconducting solenoid with 6-m-diameter
by 12.5-m-length free bore, enclosed inside a 10000-ton return yoke made of
construction steel. The return yoke consists of five dodecagonal three-layered
barrel wheels and four end-cap disks at each end comprised of steel blocks up
to 620 mm thick, which serve as the absorber plates of the muon detection
system. Accurate characterization of the magnetic field everywhere in the CMS
detector is required. To measure the field in and around the steel, a system of
22 flux-loops and 82 3-D Hall sensors is installed on the return yoke blocks.
Fast discharges of the solenoid (190 s time-constant) made during the CMS
magnet surface commissioning test at the solenoid central fields of 2.64, 3.16,
3.68 and 4.01 T were used to induce voltages in the flux-loops. The voltages
are measured on-line and integrated off-line to obtain the magnetic flux in the
steel yoke close to the muon chambers at full excitations of the solenoid. The
3-D Hall sensors installed on the steel-air interfaces give supplementary
information on the components of magnetic field and permit to estimate the
remanent field in steel to be added to the magnetic flux density obtained by
the voltages integration. A TOSCA 3-D model of the CMS magnet is developed to
describe the magnetic field everywhere outside the tracking volume measured
with the field-mapping machine. The results of the measurements and
calculations are presented, compared and discussed.Comment: 9 pages, 7 figures, 16 references, presented at the III International
Conference on Superconductivity and Magnetism (ICSM-2012), Kumburgaz,
Istanbul, Turkey, 29 April - 4 May 201
Validation of the CMS Magnetic Field Map
The Compact Muon Solenoid (CMS) is a general purpose detector, designed to
run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its
distinctive features include a 4 T superconducting solenoid with 6-m-diameter
by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of
construction steel. The return yoke consists of five dodecagonal three-layered
barrel wheels and four end-cap disks at each end comprised of steel blocks up
to 620 mm thick, which serve as the absorber plates of the muon detection
system. To measure the field in and around the steel, a system of 22 flux loops
and 82 3-D Hall sensors is installed on the return yoke blocks. A TOSCA 3-D
model of the CMS magnet is developed to describe the magnetic field everywhere
outside the tracking volume measured with the field-mapping machine. The
magnetic field description is compared with the measurements and discussed.Comment: 7 pages, 5 figures, presented at 4th International Conference on
Superconductivity and Magnetism 2014, April 27 - May 2, 2014, Antalya,
Turkey. arXiv admin note: substantial text overlap with arXiv:1605.08778;
text overlap with arXiv:1212.165
Practical guidelines for familial combined hyperlipidemia diagnosis: an up-date
Familial combined hyperlidemia (FCH) is a common metabolic disorder characterized by: (a) increase in cholesterolemia and/or triglyceridemia in at least two members of the same family, (b) intra-individual and intrafamilial variability of the lipid phenotype, and (c) increased risk of premature coronary heart disease (CHD). FCH is very frequent and is one of the most common genetic hyperlipidemias in the general population (prevalence estimated: 0.5%–2.0%), being the most frequent in patients affected by CHD (10%) and among acute myocardial infarction survivors aged less than 60 (11.3%). This percentage increases to 40% when all the myocardial infarction survivors are considered without age limits. However, because of the peculiar variability of laboratory parameters, and because of the frequent overlapping with the features of metabolic syndrome, this serious disease is often not recognized and treated. The aim of this review is to define the main characteristics of the disease in order to simplify its detection and early treatment by all physicians by mean of practical guidelines
High prevalence of patent foramen ovale in migraine with aura
In this study we evaluated the presence of patent foramen ovale (PFO) in a cohort of 25 consecutive patients suffering from migraine with aura (MA) during an attack presenting to the emergency ward of an Italian hospital. Patients underwent brain magnetic resonance imaging (MRI) with contrast medium, routine coagulation tests, contrast transcranial echocolour–coded sonography (c–TCCS) and transoesophageal echocardiography (TEE). Of the enrolled patients, 88.7% showed a PFO according to the c–TCCS test, whereas only in 72% TEE confirmed the presence of PFO. This discordance could be due to the fact that c–TCCS is more sensitive even with shunts with minimal capacity also located in the pulmonary vasculature. After surgical treatment of the PFO, MA disappeared within two months. Also, the treatment with warfarin as well as with acetylsalicylic acid and flunarizine was able to dramatically reduce the frequency of migraine attacks. These data indicate a higher prevalence of PFO in MA vs. normal population (OR=2.92) and could suggest that the presence of arteriovenous (AV) shunts could represent a trigger for MA attacks as well as for stroke, but more studies are needed to confirm this preliminary hypothesis
- …