53 research outputs found

    Neurospora from natural populations: Population genomics insights into the Life history of a model microbial Eukaryote

    Get PDF
    The ascomycete filamentous fungus Neurospora crassa played a historic role in experimental biology and became a model system for genetic research. Stimulated by a systematic effort to collect wild strains initiated by Stanford geneticist David Perkins, the genus Neurospora has also become a basic model for the study of evolutionary processes, speciation, and population biology. In this chapter, we will first trace the history that brought Neurospora into the era of population genomics. We will then cover the major contributions of population genomic investigations using Neurospora to our understanding of microbial biogeography and speciation, and review recent work using population genomics and genome-wide association mapping that illustrates the unique potential of Neurospora as a model for identifying the genetic basis of (potentially adaptive) phenotypes in filamentous fungi. The advent of population genomics has contributed to firmly establish Neurospora as a complete model system and we hope our review will entice biologists to include Neurospora in their research

    Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization

    Get PDF
    The original Riva-Rocci method to measure blood pressure (BP) using a cuff at the upper arm assumed the pressure obtained by this technique was a good proxy for central aortic BP.1,2 The clinical (prognostic) importance of brachial cuff BP is undeniable for both the assessment of cardiovascular risk associated with elevated BP and the benefits of treatment-induced BP reduction.3 However, it is also generally appreciated that peripheral artery systolic BP (SBP; brachial or radial artery) may be an inaccurate substitute for central SBP.4 This has been reported in human studies using intra-arterial catheterization of peripheral and central arteries.5–8 There may also be a discrepancy between peripheral and central BP responses to vasoactive drugs.9 These findings are corroborated in larger studies using non-invasive central aortic BP methods,10–13 and, while yet to be fully adopted in clinical practice, an independent prognostic value of central BP has been demonstrated.14–16 Altogether, there is a growing interest among clinicians towards improving risk estimates by using devices that provide more accurate measures of central aortic BP than those provided by current brachial cuff BP methods. Many non-invasive devices have been developed that purport to estimate central BP from different peripheral artery sites (e.g. radial, brachial, carotid arteries) using different principles of recording the pressure or surrogate signals (e.g. applanation tonometry, oscillometry, ultrasound, or magnetic resonance imaging) and different calibration methods to derive central BP. Since upper arm cuff-based devices to estimate central BP are more clinically appealing, in recent years several companies have developed such devices using a variety of techniques (e.g. oscillometric sub-diastolic or supra-systolic waveform analysis with generalized transfer functions), which employ a variety of signal processing steps to estimate central BP from peripheral signals.17,18 Yet, with no standardized guidelines,17 the accuracy testing of these new devices (as well as the preceding devices) has not been undertaken in a uniform fashion with comparable protocols, emphasizing the need for guidance in this field.19–22 An international task force was convened to address this situation

    Cisplatin anti-tumour potentiation by tirapazamine results from a hypoxia-dependent cellular sensitization to cisplatin

    Get PDF
    Tirapazamine (TPZ) is a new anticancer drug that is activated specifically at the low oxygen level typically found in solid tumours. It exhibits preferential cytotoxicity towards hypoxic cells and has been shown in preclinical studies with transplanted tumours and in phase II and III clinical trials to potentiate the anti-tumour efficacy of cisplatin without increasing its systemic toxicity. At present, the mechanism for this potentiation is unknown. Here we show that there is a schedule-dependent enhancement of cisplatin cytotoxicity by TPZ for cells in vitro that is similar to that seen with transplanted murine tumours. This cisplatin potentiation depends on the TPZ exposure being at oxygen concentrations below 1%, which are typical of many cells in tumours but not in normal tissues. Also, the interaction between TPZ and cisplatin does not occur in cells mutant in ERCC4, a protein essential for repair of DNA interstrand cross-links. Incubation of the cells with TPZ under hypoxia prior to cisplatin treatment increases cisplatin-induced DNA interstrand cross-links with kinetics suggesting that TPZ inhibits or delays repair of the DNA cross-links. In conclusion, we show that the tumour-specific potentiation of cisplatin cytotoxicity is likely the result of an interaction between TPZ and cisplatin at the cellular level that requires the low oxygen levels typical of those in solid tumours. The mechanism of the interaction appears to be through a potentiation of cisplatin-induced DNA interstrand cross-links, possibly as a result of a diminished or delayed repair of these lesion

    Non-invasive cardiac imaging techniques and vascular tools for the assessment of cardiovascular disease in type 2 diabetes mellitus

    Get PDF
    Cardiovascular disease is the major cause of mortality in type 2 diabetes mellitus. The criteria for the selection of those asymptomatic patients with type 2 diabetes who should undergo cardiac screening and the therapeutic consequences of screening remain controversial. Non-invasive techniques as markers of atherosclerosis and myocardial ischaemia may aid risk stratification and the implementation of tailored therapy for the patient with type 2 diabetes. In the present article we review the literature on the implementation of non-invasive vascular tools and cardiac imaging techniques in this patient group. The value of these techniques as endpoints in clinical trials and as risk estimators in asymptomatic diabetic patients is discussed. Carotid intima–media thickness, arterial stiffness and flow-mediated dilation are abnormal long before the onset of type 2 diabetes. These vascular tools are therefore most likely to be useful for the identification of ‘at risk’ patients during the early stages of atherosclerotic disease. The additional value of these tools in risk stratification and tailored therapy in type 2 diabetes remains to be proven. Cardiac imaging techniques are more justified in individuals with a strong clinical suspicion of advanced coronary heart disease (CHD). Asymptomatic myocardial ischaemia can be detected by stress echocardiography and myocardial perfusion imaging. The more recently developed non-invasive multi-slice computed tomography angiography is recommended for exclusion of CHD, and can therefore be used to screen asymptomatic patients with type 2 diabetes, but has the associated disadvantages of high radiation exposure and costs. Therefore, we propose an algorithm for the screening of asymptomatic diabetic patients, the first step of which consists of coronary artery calcium score assessment and exercise ECG

    Validation of non-invasive central blood pressure devices: Artery society task force (abridged) consensus statement on protocol standardization

    Get PDF
    Brachial cuff blood pressure (BP) is clinically important, but may be an inaccurate substitute for central BP. Many non-invasive devices have been developed that purport to estimate central BP from peripheral artery sites, yet with no standardized guidelines; the accuracy testing of these new devices has not been undertaken in a uniform fashion with comparable protocols. This is an abridged paper describing the recommendations reached by an international task force convened to identify issues that need to be addressed and reach consensus relating to methods for assessing and reporting the accuracy (validation) of central BP devices. The recommendations are endorsed by the Association for Research into Arterial Structure and Physiology (ARTERY) Society, as well as the European Society of Hypertension (ESH) Working Group on Arterial Structure and Function, and the ESH Working Group on Blood Pressure Monitoring and Cardiovascular Variability. Researchers interested in validating central BP monitors should read the full version of the statement

    Linear electro‐optic dispersion in (‐)‐2‐(α‐methylbenzylamino)‐5‐nitropyridine single crystals

    No full text
    The variation of the linear electro-optic effect in (-)-2-(alpha-methylbenzylamino)-5-nitropyridine with the wavelength of the incident light at room temperature has been measured. The reduced half-wave voltages have been found to have the values 2.1, 2.8, and 6.0 kV at 488, 514.5, and 632.8 nm respectively and the corresponding values of the linear electro-optic coefficient have been evaluated.;The interpretation of the results in terms of the structures of the molecule and the crystal is discussed. The thermal variation of the birefringence has also been investigated and the coefficient for the temperature variation of the refractive index difference is found to have the value (d Delta n/dT)=9.3X10(-5) K-1

    Linear electro-optic effect and temperature coefficient of birefringence in 4-nitro-4script-methylbenzylidene aniline single crystals

    No full text
    A study of the linear electro?optic effect in single crystals of the organic compound, 4?nitro�4??methylbenzylidene aniline is reported. The reduced half?wave voltages have been found to have values 2.8, 1.3, and 1.1 kV at 632.8, 514.5, and 488.0 nm, respectively and the corresponding values of the largest linear electro?optic coefficient have been calculated. The thermal variation of the birefringence has also been investigated and the temperature variation of the refractive index difference is found to have the value, d?n/dT = 15.8 × 10?5 K?1
    corecore