9,063 research outputs found

    A Derivation of Three-Dimensional Inertial Transformations

    Get PDF
    The derivation of the transformations between inertial frames made by Mansouri and Sexl is generalised to three dimensions for an arbitrary direction of the velocity. Assuming lenght contraction and time dilation to have their relativistic values, a set of transformations kinematically equivalent to special relativity is obtained. The ``clock hypothesis'' allows the derivation to be extended to accelerated systems. A theory of inertial transformations maintaining an absolute simultaneity is shown to be the only one logically consistent with accelerated movements. Algebraic properties of these transformations are discussed. Keywords: special relativity, synchronization, one-way velocity of light, ether, clock hypothesis.Comment: 16 pages (A5), Latex, one figure, to be published in Found. Phys. Lett. (1997

    Paleo and historical seismicity in Mallorca (Baleares, Spain): a preliminary approach

    Get PDF
    The island of Mallorca is subject to low seismic activity. The instrumental record shows that current seismicity is surficial (La isla de Mallorca presenta una actividad sĂ­smica baja. El registro instrumental muestra que la sismicidad actual es superficial

    A direct kinematical derivation of the relativistic Sagnac effect for light or matter beams

    Full text link
    The Sagnac time delay and the corresponding Sagnac phase shift, for relativistic matter and electromagnetic beams counter-propagating in a rotating interferometer, are deduced on the ground of relativistic kinematics. This purely kinematical approach allows to explain the ''universality'' of the effect, namely the fact that the Sagnac time difference does not depend on the physical nature of the interfering beams. The only prime requirement is that the counter-propagating beams have the same velocity with respect to any Einstein synchronized local co-moving inertial frame.Comment: 10 pages, 1 EPS figure, to appear in General Relativity and Gravitatio

    Time on a Rotating Platform

    Get PDF
    Traditional clock synchronisation on a rotating platform is shown to be incompatible with the experimentally established transformation of time. The latter transformation leads directly to solve this problem through noninvariant one-way speed of light. The conventionality of some features of relativity theory allows full compatibility with existing experimental evidence.Comment: 12 pages, Latex, no figure. Copies available at [email protected] accepted for publication in Found. Phys. Let

    Heterodyne detection of multiply scattered monochromatic light with a multipixel detector

    No full text
    International audienceA new technique is presented for measuring the spectral broadening of light that has been multiply scattered from scatterers in motion. In our method the scattered light is detected by a heterodyne receiver that uses a CCD as a multipixel detector. We obtain the frequency spectrum of the scattered light by sweeping the heterodyne local oscillator frequency. Our detection scheme combines a high optical etendue (product of the surface by the detection solid angle) with an optimal detection of the scattered photons (shot noise). Using this technique, we measure, in vivo, the frequency spectrum of the light scattered through the breast of a female volunteer

    The electromagnetic calorimeter of the AMS-02 experiment

    Full text link
    The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and 72 sampling in the lateral direction. The ECAL primary goal is to measure the energy of cosmic rays up to few TeV, however, thanks to the fine grained structure, it can also provide the separation of positrons from protons, in the GeV to TeV region. A direct measurement of high energy photons with accurate energy and direction determination can also be provided.Comment: Proceedings of SF2A conference 201

    Spontaneous Emission in Chaotic Cavities

    Get PDF
    The spontaneous emission rate \Gamma of a two-level atom inside a chaotic cavity fluctuates strongly from one point to another because of fluctuations in the local density of modes. For a cavity with perfectly conducting walls and an opening containing N wavechannels, the distribution of \Gamma is given by P(\Gamma) \propto \Gamma^{N/2-1}(\Gamma+\Gamma_0)^{-N-1}, where \Gamma_0 is the free-space rate. For small N the most probable value of \Gamma is much smaller than the mean value \Gamma_0.Comment: 4 pages, RevTeX, 1 figur

    A Novel Device for the Measurement of the Mechanical and Magnetic Axes of Superconducting Magnet Assemblies for Accelerators

    Get PDF
    In the context of the LHC superconducting magnet production, especially for dipoles and quadrupoles due to their complexity, it is foreseen to perform acceptance tests, at an early production stage, to detect possible significant deviations from the design values. The knowledge of the magnetic field geometry is very important, especially for the main magnets. In order to get this information a new device has been conceived that measures the magnets at room temperature during different stages of construction. This device incorporates a sensitive measuring probe and an efficient data acquisition system because the coils are only powered at about 10-5 of the nominal D.C. current. It is dedicated to Quadrupole and Dipole (by using Quadrupole-Configured Dipole (QCD) transformation) magnets, but is also easily adaptable to higher order magnets (n = 3, 4 and 5) by specific orientation of the search coils. It is equipped with magnetic sensors (4 fixed tangential coils and AC excitation current for the magnet) and position sensors (3D-laser tracker and light reflector) that allow the simultaneous detection of the magnetic field axis and the cold bore axis. It is equipped as well with a set of 4 LEDs and associated with a CCD camera that allows both the measurement of the cold bore diameter and its position with respect to the mole. This paper describes the system and reports the first results measured on the pre-series magnets recently assembled
    • 

    corecore