81 research outputs found

    Malpractice and patient safety descriptors: an innovative grid to evaluate the quality of clinical records

    Get PDF
    Introduction: The medical record contains all the health information related to the patient’s clinical condition and its evolution during hospitalization. It was defined by the Italian Ministry of Health in 1992 as "The information tool designed to record all relevant demographic and clinical information about a patient during a single episode of hospitalization". The documents and information in a Medical Record must meet the following criteria: traceability, clarity, accuracy, authenticity, pertinence and completeness. The objectives of our study was to develop a tool capable of assessing the quality of the clinical record and pointed the critical point at the Organizational, Technical - Professional, Managerial level. Methods: To evaluate the quality of the medical documentation, we created an assessment grid composed of 4 sections with a total of 92 criteria. This grid was tested on 200 medical records that were randomly selected from 25 (18 medical and 7 surgical) wards of a teaching hospital in Rome. Results: The grid contains 4 sections. The first part regards administrative and clinical data; the second assesses the quality of hospital stay and surgical/invasive procedures; the third part is concerned with the discharge of the patient and the fourth aims to identify the presence of advisory reports given to the patient. This grid has been validated to verify internal consistency with Cronbach's Alpha = 0,743. Conclusions: Medical records were analyzed using a validated tool with grids to identify critical issues in care activities. Weaknesses in the system were identified in order to improve planning. The sample testing also in terms of ‘self-assessment' represents a tool to introduce activities to improve safety and quality of care, greatly reducing the costs of litigation

    Right Ventricular Strain and Dyssynchrony Assessment in Arrhythmogenic Right Ventricular Cardiomyopathy: Cardiac Magnetic Resonance Feature-Tracking Study

    Get PDF
    BACKGROUND: Analysis of right ventricular (RV) regional dysfunction by cardiac magnetic resonance (CMR) imaging in arrhythmogenic RV cardiomyopathy (ARVC) may be inadequate because of the complex contraction pattern of the RV. Aim of this study was to determine the use of RV strain and dyssynchrony assessment in ARVC using feature-tracking CMR analysis. METHODS AND RESULTS: Thirty-two consecutive patients with ARVC referred to CMR imaging were included. Thirty-two patients with idiopathic RV outflow tract arrhythmias and 32 control subjects, matched for age and sex to the ARVC group, were included for comparison purpose. CMR imaging was performed to assess biventricular function; feature-tracking analysis was applied to the cine CMR images to assess regional and global longitudinal, circumferential, and radial RV strains and RV dyssynchrony (defined as the SD of the time-to-peak strain of the RV segments). RV global longitudinal strain (-17\ub15% versus -26\ub16% versus -29\ub16%; P-23.2%, SD of the time-to-peak RV longitudinal strain >113.1 ms, and SD of the time-to-peak RV circumferential strain >177.1 ms allowed correct identification of 88%, 75%, and 63% of ARVC patients with no or only minor CMR criteria for ARVC diagnosis. CONCLUSIONS: Strain analysis by feature-tracking CMR helps to objectively quantify global and regional RV dysfunction and RV dyssynchrony in patients with ARVC and provides incremental value over conventional cine CMR imaging

    INTERMUSCULAR TWO-INCISION TECHNIQUE FOR S-ICD IMPLANTATION

    Get PDF
    Background The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, which involves three incisions and a subcutaneous pocket, is associated with possible complications, including inappropriate interventions. The aim of this prospective multicenter study was to evaluate the efficacy and safety of an alternative intermuscular two-incision technique for S-ICD implantation. Methods The study population included 36 consecutive patients (75% male, mean age 44 ± 12 years [range 20–69]) who underwent S-ICD implantation using the intermuscular two-incision technique. This technique avoids the superior parasternal incision for the lead placement and consists of creating an intermuscular pocket between the anterior surface of the serratus anterior and the posterior surface of the latissimus dorsi muscles instead of a subcutaneous pocket. Results All patients were successfully implanted in the absence of any procedure-related complications with a successful 65-J standard polarity defibrillation threshold testing, except in one, who received a second successful shock after pocket revision. During a mean follow-up of 10 months (range 3–30), no complications requiring surgical revision were observed. At device interrogation, stable sensing without interferences was observed in all patients. Two patients (5.5%) experienced appropriate and successful shock on ventricular fibrillation and in four patients (11%), a total of seven nonsustained self-terminated ventricular tachycardias were correctly detected. No inappropriate interventions were observed. Conclusions Our experience suggests that the two-incision intermuscular technique is a safe and efficacious alternative to the current technique for S-ICD implantation that may help reducing complications including inappropriate interventions and offer a better cosmetic outcome, especially in thin individuals

    Aerosol delivery through high-flow nasal therapy: Technical issues and clinical benefits

    Get PDF
    High-flow nasal cannula (HFNC) therapy is an oxygen delivery method particularly used in patients affected by hypoxemic respiratory failure. In comparison with the conventional “low flow” oxygen delivery systems, it showed several important clinical benefits. The possibility to nebulize drugs via HFNC represents a desirable medical practice because it allows the administration of inhaled drugs, mostly bronchodilators, without the interruption or modification of the concomitant oxygen therapy. HFNC, by itself has shown to exert a small but significant bronchodilator effect and improves muco-ciliary clearance; thus, the nebulization of bronchodilators through the HFNC circuit may potentially increase their pharmacological activity. Several technical issues have been observed which include the type of the nebulizer that should be used, its position within the HFNC circuit, and the optimal gas flow rates to ensure an efficient drug delivery to the lungs both in “quiet” and “distressed” breathing patterns. The aim of this review has been to summarize the scientific evidence coming from “in vitro” studies and to discuss the results of “in vivo” studies performed in adult subjects, mainly affected by obstructive lung diseases. Most studies seem to indicate the vibrating mesh nebulizer as the most efficient type of nebulizer and suggest to place it preferentially upstream from the humidifier chamber. In a quite breathing patterns, the inhaled dose seems to increase with lower flow rates while in a “distressed” breathing pattern, the aerosol delivery is higher when gas flow was set below the patient’s inspiratory flow, with a plateau effect seen when the gas flow reaches approximately 50% of the inspiratory flow. Although several studies have demonstrated that the percentage of the loaded dose nebulized via HFNC reaching the lungs is small, the bronchodilator effect of albuterol seems not to be impaired when compared to the conventional inhaled delivery methods. This is probably attributed to its pharmacological activity. Prospective and well-designed studies in different cohort of patients are needed to standardize and demonstrate the efficacy of the procedure

    Association between air pollution and ventricular arrhythmias in high-risk patients (ARIA study): a multicentre longitudinal study

    Get PDF
    Summary Background Although the effects of air pollution on mortality have been clearly shown in many epidemiological and observational studies, the pro-arrhythmic effects remain unknown. We aimed to assess the short-term effects of air pollution on ventricular arrhythmias in a population of high-risk patients with implantable cardioverter-defibrillators (ICDs) or cardiac resynchronisation therapy defibrillators (ICD-CRT). Methods In this prospective multicentre study, we assessed 281 patients (median age 71 years) across nine centres in the Veneto region of Italy. Episodes of ventricular tachycardia and ventricular fibrillation that were recorded by the diagnostic device were considered in this analysis. Concentrations of particulate matter of less than 10 Όm (PM 10 ) and less than 2·5 Όm (PM 2·5 ) in aerodynamic diameter, carbon monoxide, nitrogen dioxide, sulphur dioxide, and ozone were obtained daily from monitoring stations, and the 24 h median value was considered. Each patient was associated with exposure data from the monitoring station that was closest to their residence. Patients were followed up for 1 year and then scheduled to have a closing visit, within 1 more year. This study is registered with ClinicalTrials.gov, number NCT01723761. Findings Participants were enrolled from April 1, 2011, to Sept 30, 2012, and follow-ups (completed on April 5, 2014) ranged from 637 to 1177 days (median 652 days). The incidence of episodes of ventricular tachycardia and ventricular fibrillation correlated significantly with PM 2·5 (p 10 . An analysis of ventricular fibrillation episodes alone showed a significant increase in risk of higher PM 2·5 (p=0·002) and PM 10 values (p=0·0057). None of the gaseous pollutants were significantly linked to the occurrence of ventricular tachycardia or ventricular fibrillation. In a subgroup analysis of patients with or without a previous myocardial infarction, only the first showed a significant association between particulate matter and episodes of ventricular tachycardia or ventricular fibrillation. Interpretation Particulate matter has acute pro-arrhythmic effects in a population of high-risk patients, which increase on exposure to fine particles and in patients who have experienced a previous myocardial infarction. The time sequence of the arrhythmic events suggests there is an underlying neurally mediated mechanism. From a clinical point of view, the results of our study should encourage physicians to also consider environmental risk when addressing the prevention of arrhythmic events, particularly in patients with coronary heart disease, advising them to avoid exposure to high levels of fine particulate matter. Funding There was no funding source for this study

    Measurement of gravitational and thermal effects in a liquid-actuated torsion pendulum

    Get PDF
    We describe a proof-of-principle experiment aiming to investigate the inverse-square law of gravitation at the centimeter scale. The sensor is a two-stage torsion pendulum, while actuation is accomplished by a variable liquid mass. The time-varying gravitational force is related to the level of the circulating fluid in one or two containers at a short distance from the test mass, with all moving mechanical parts positioned at a large distance. We provide a description of the apparatus and present the first results. We identified a systematic effect of thermal origin, producing offsets of few fNm in torque and of about 10 pN in force. When this effect is neutralized, the measurements agree well with the predictions of simulations. We also discuss the upcoming instrument upgradations and the expected sensitivity improvement that will allow us to perform measurements with adequate accuracy to investigate the unexplored regions of the α−λ parameter space of a Yukawa-like deviation from the Newtonian potential
    • 

    corecore