1,892 research outputs found

    New Concepts for Shipboard Sea State Estimation

    Get PDF

    A Microcalorimeter and Bolometer Model

    Full text link
    The standard non-equilibrium theory of noise in ideal bolometers and microcalorimeters fails to predict the performance of real devices due to additional effects that become important at low temperature. In this paper we extend the theory to include the most important of these effects, and find that the performance of microcalorimeters operating at 60 mK can be quantitatively predicted. We give a simple method for doing the necessary calculations, borrowing the block diagram formalism from electronic control theory.Comment: 20 pages, 15 figure

    Lithium Experiment on Solar Neutrinos to Weight the CNO Cycle

    Full text link
    The measurement of the flux of beryllium neutrinos with the accuracy of about 10% and CNO neutrinos with the accuracy 30% will enable to find the flux of pp-neutrinos in the source with the accuracy better than 1% using the luminosity constraint. The future experiments on \nu e- scattering will enable to measure with very good accuracy the flux of beryllium and pp-neutrinos on the Earth. The ratio of the flux of pp-neutrinos on the Earth and in the source will enable to find with very good accuracy a mixing angle theta solar. Lithium detector has high sensitivity to CNO neutrinos and can find the contribution of CNO cycle to the energy generated in the Sun. This will be a stringent test of the theory of stellar evolution and combined with other experiments will provide a precise determination of the flux of pp-neutrinos in the source and a mixing angle theta solar. The work on the development of the technology of lithium experiment is now in progress.Comment: Minor corrections, one reference added, 11 pages, 2 figures, talk given at NANP 2003, Dubna, Russia, June 200

    Prevalence of Baker's cyst in patients with knee pain: an ultrasonographic study

    Get PDF
    The objectives of this study are to investigate the prevalence of Baker's cyst (BC) in patients with knee pain, and to assess the correlation between BC and severity of osteophytes and joint effusion. A retrospective study was conducted on a group of patients with knee pain referred to our outpatient clinic for ultrasonography of the knee between January 2010 and February 2011. Patients underwent an ultrasonographic exam of the knees to assess the presence of marginal femorotibial osteophytosis, joint effusion and BC. A dichotomous score was assigned to each item (1 present, 0 absent) and severity of US signs of osteoarthritis and joint effusion were also graded semiquantitatively. Collected data were processed using logistic regression analysis to evaluate the correlation between degree of osteophytosis and joint effusion and BC. Patients affected by inflammatory joint conditions or with history of joint surgery or recent trauma were excluded. A total of 399 patients with knee pain were studied (299 women), in the age range 18-89 years (mean 56.2, SD 16.3 years). 293 patients (73.4%) showed sonographic features of osteoarthritis and 251 (62.9%) joint effusion. BC was found in 102 patients (25.8%) together with a positive association with sonographic features of osteoarthritis and joint effusion. Our data show a prevalence of BC of 25.8% in a population of patients with knee pain, and suggest that BC is positively related to osteoarthritis and joint effusion. Ultrasonographic examination of knee is worthwhile in patients with painful osteoarthritis or evidence of effusion

    Observed Limits on Charge Exchange Contributions to the Diffuse X-ray Background

    Get PDF
    We present a high resolution spectrum of the diffuse X-ray background from 0.1 to 1 keV for a ~1 region of the sky centered at l=90, b=+60 using a 36-pixel array of microcalorimeters flown on a sounding rocket. With an energy resolution of 11 eV FWHM below 1 keV, the spectrum's observed line ratios help separate charge exchange contributions originating within the heliosphere from thermal emission of hot gas in the interstellar medium. The X-ray sensitivity below 1 keV was reduced by about a factor of four from contamination that occurred early in the flight, limiting the significance of the results. The observed centroid of helium-like O VII is 568+2-3 eV at 90% confidence. Since the centroid expected for thermal emission is 568.4 eV while for charge exchange is 564.2 eV, thermal emission appears to dominate for this line complex, consistent with much of the high-latitude O VII emission originating in 2-3 x 10^6 K gas in the Galactic halo. On the other hand, the observed ratio of C VI Ly gamma to Ly alpha is 0.3+-0.2. The expected ratios are 0.04 for thermal emission and 0.24 for charge exchange, indicating that charge exchange must contribute strongly to this line and therefore potentially to the rest of the ROSAT R12 band usually associated with 10^6 K emission from the Local Hot Bubble. The limited statistics of this experiment and systematic uncertainties due to the contamination require only >32% thermal emission for O VII and >20% from charge exchange for C VI at the 90% confidence level. An experimental gold coating on the silicon substrate of the array greatly reduced extraneous signals induced on nearby pixels from cosmic rays passing through the substrate, reducing the triggered event rate by a factor of 15 from a previous flight of the instrument.Comment: 14 pages, 7 figures, to be published in Ap

    Testing the neutrality of matter by acoustic means in a spherical resonator

    Full text link
    New measurements to test the neutrality of matter by acoustic means are reported. The apparatus is based on a spherical capacitor filled with gaseous SF6_6 excited by an oscillating electric field. The apparatus has been calibrated measuring the electric polarizability. Assuming charge conservation in the β\beta decay of the neutron, the experiment gives a limit of ϵp-e11021\epsilon_\text{p-e}\lesssim1\cdot10^{-21} for the electron-proton charge difference, the same limit holding for the charge of the neutron. Previous measurements are critically reviewed and found incorrect: the present result is the best limit obtained with this technique

    Scintillating properties of frozen new liquid scintillators

    Get PDF
    The light emission from scintillators which are liquid at room temperature was studied in the interval between +20+20~^{\circ}C and 120-120~^{\circ}C, where the phase transition from liquid to solid takes place. The light yield measured at 120-120~^{\circ}C is about twice as much as that observed at +20+20~^{\circ}C. By cooling the scintillator from +20+20~^{\circ}C to 120-120~^{\circ}C and then heating it from 120-120~^{\circ}C to +20+20~^{\circ}C, the light yield varies in steps at well defined temperatures, which are different for the cooling and heating processes. These hysteresis phenomena appear to be related to the solvent rather than to the dopant. The decay time of scintillation light was measured at +20+20~^{\circ}C and 120-120~^{\circ}C. Whilst at room temperature most of the light is emitted with a decay time of 6--8 ns, at 120-120~^{\circ}C a slower component, with a decay time of 25--35 ns, becomes important

    Normalizing glycosphingolipids restores function in CD4+ T cells from lupus patients

    Get PDF
    Patients with the autoimmune rheumatic disease systemic lupus erythematosus (SLE) have multiple defects in lymphocyte signaling and function that contribute to disease pathogenesis. Such defects could be attributed to alterations in metabolic processes, including abnormal control of lipid biosynthesis pathways. Here, we reveal that CD4+ T cells from SLE patients displayed an altered profile of lipid raft–associated glycosphingolipids (GSLs) compared with that of healthy controls. In particular, lactosylceramide, globotriaosylceramide (Gb3), and monosialotetrahexosylganglioside (GM1) levels were markedly increased. Elevated GSLs in SLE patients were associated with increased expression of liver X receptor β (LXRβ), a nuclear receptor that controls cellular lipid metabolism and trafficking and influences acquired immune responses. Stimulation of CD4+ T cells isolated from healthy donors with synthetic and endogenous LXR agonists promoted GSL expression, which was blocked by an LXR antagonist. Increased GSL expression in CD4+ T cells was associated with intracellular accumulation and accelerated trafficking of GSL, reminiscent of cells from patients with glycolipid storage diseases. Inhibition of GSL biosynthesis in vitro with a clinically approved inhibitor (N-butyldeoxynojirimycin) normalized GSL metabolism, corrected CD4+ T cell signaling and functional defects, and decreased anti-dsDNA antibody production by autologous B cells in SLE patients. Our data demonstrate that lipid metabolism defects contribute to SLE pathogenesis and suggest that targeting GSL biosynthesis restores T cell function in SLE

    DXL: a sounding rocket mission for the study of solar wind charge exchange and local hot bubble X-ray emission

    Get PDF
    The Diffuse X-rays from the Local galaxy (DXL) mission is an approved sounding rocket project with a first launch scheduled around December 2012. Its goal is to identify and separate the X-ray emission generated by solar wind charge exchange from that of the local hot bubble to improve our understanding of both. With 1,000 cm2 proportional counters and grasp of about 10 cm2 sr both in the 1/4 and 3/4 keV bands, DXL will achieve in a 5-minute flight what cannot be achieved by current and future X-ray satellites.Comment: 15 Pages, 5 figures. Accepted for publication on Experimental Astronom
    corecore