1,005 research outputs found
Improving the system capacity of broadband services using multiple high-altitude platforms
A method of significantly improving the capacity of high-altitude platform (HAP) communications networks operating in the millimeter-wave bands is presented. It is shown how constellations of HAPs can share a common frequency allocation by exploiting the directionality of the user antenna. The system capacity of such constellations is critically affected by the minimum angular separation of the HAPs and the sidelobe level of the user antenna. For typical antenna beamwidths of approximately 5/spl deg/ an inter-HAP spacing of 4 km is sufficient to deliver optimum performance. The aggregate bandwidth efficiency is evaluated, both theoretically using the Shannon equation, and using practical modulation and coding schemes, for multiple HAP configurations delivering either single or multiple cells. For the user antenna beamwidths used, it is shown that capacity increases are commensurate with the increase in the number of platforms, up to 10 HAPs. For increases beyond this the choice of constellation strategy becomes increasingly important
Strategies to Increase Representation of Students with Disabilities in Science, Technology, Engineering and Mathematics (STEM)
As a nation wrestles with the need to train more professionals, persons with disabilities are undereducated and underrepresented in science, technology, engineering, and mathematics (STEM). The following project was proposed to increase representation of students with disabilities in the STEM disciplines. The program emphasizes an integrated program of interventions for college students with disabilities (SwD) majoring in STEM which centers on a system of continuous student monitoring with rapid access to academic and personal services, as well as professional development and degree enhancing experiences supplied during the entire period of college attendance
Recommended from our members
Time variations of interstellar water masers in HII regions
Fourteen water maser sources associated with HII regions have been monitored over the period September 1974-May 1977. Time variations have been observed with a range of time-scales from days to years. A statistical analysis of the short- and long-term variations is performed and related variability in features of similar velocity is examined. The time variations must be due to changes in the pump input, geometry or other physical properties of the maser regions but at present no adequate theory exists to describe the complex behavior observed
The Retention of Women in Science, Technology, Engineering, and Mathematics: A Framework for Persistence
Women make up 47% of the total U.S. workforce, but are less represented in engineering, computer sciences, and the physical sciences. In addition, race and ethnicity are salient factors and minority women comprise fewer than 1 in 10 scientist or engineer. In this paper, a review of the literature is under taken that explores the many challenges women encounter when pursing a career in the sciences. It includes a review of the national landscape and discussion of the guiding general retention theories. Finally it proposes a conceptual framework for persistence and proffers a number of research questions designed to delve deeper into the under representation phenomenon
Factorization of shell-model ground-states
We present a new method that accurately approximates the shell-model
ground-state by products of suitable states. The optimal factors are determined
by a variational principle and result from the solution of rather
low-dimensional eigenvalue problems. The power of this method is demonstrated
by computations of ground-states and low-lying excitations in sd-shell and
pf-shell nuclei.Comment: 5+epsilon pages, 5 eps-figures. Main additions: wave-function
overlaps, angular momentum expectation values, application to Ni56. To be
published as Rapid Communication in PR
Heterodyne-assisted pulsed spectroscopy with a nearly Fourier-transform limited, injection-seeded optical parametric oscillator
Mitsuhiko Kono, Kenneth G. Baldwin, Yabai He, Richard T. White and Brian J. Or
Six-minute walk distance after coronary artery bypass grafting compared with medical therapy in ischaemic cardiomyopathy
Background: In patients with ischaemic left ventricular dysfunction, coronary artery bypass surgery (CABG) may decrease mortality, but it is not known whether CABG improves functional capacity.
Objective: To determine whether CABG compared with medical therapy alone (MED) increases 6 min walk distance in patients with ischaemic left ventricular dysfunction and coronary artery disease amenable to revascularisation.
Methods: The Surgical Treatment in Ischemic Heart disease trial randomised 1212 patients with ischaemic left ventricular dysfunction to CABG or MED. A 6 min walk distance test was performed both at baseline and at least one follow-up assessment at 4, 12, 24 and/or 36 months in 409 patients randomised to CABG and 466 to MED. Change in 6 min walk distance between baseline and follow-up were compared by treatment allocation.
Results: 6 min walk distance at baseline for CABG was mean 340±117 m and for MED 339±118 m. Change in walk distance from baseline was similar for CABG and MED groups at 4 months (mean +38 vs +28 m), 12 months (+47 vs +36 m), 24 months (+31 vs +34 m) and 36 months (−7 vs +7 m), P>0.10 for all. Change in walk distance between CABG and MED groups over all assessments was also similar after adjusting for covariates and imputation for missing values (+8 m, 95% CI −7 to 23 m, P=0.29). Results were consistent for subgroups defined by angina, New York Heart Association class ≥3, left ventricular ejection fraction, baseline walk distance and geographic region.
Conclusion: In patients with ischaemic left ventricular dysfunction CABG compared with MED alone is known to reduce mortality but is unlikely to result in a clinically significant improvement in functional capacity
Are bioresorbable polylactate devices comparable to titanium devices for stabilizing Le Fort I advancement?
AbstractThe purpose of this study was to evaluate whether skeletal and dental outcomes following Le Fort I surgery differed when stabilization was performed with polylactate bioresorbable devices or titanium devices. Fifty-seven patients with preoperative records and at least 1 year postoperative records were identified and grouped according to the stabilization method. All cephalometric X-rays were traced and digitized by a single operator. Analysis of covariance was used to compare the postsurgical change between the two stabilization methods. Twenty-seven patients received bioresorbable devices (group R), while 30 received titanium devices (group M). There were no statistically significant differences between the two groups with respect to gender, race/ethnicity, age, or dental and skeletal movements during surgery. Subtle postsurgical differences were noted, but were not statistically significant. Stabilization of Le Fort I advancement with polylactate bioresorbable and titanium devices produced similar clinical outcomes at 1 year following surgery
Interferometric diameters of five evolved intermediate-mass planet-hosting stars measured with PAVO at the CHARA Array
Debate over the planet occurrence rates around intermediate-mass stars has hinged on the accurate determination of masses of evolved stars, and has been exacerbated by a paucity of reliable, directly measured fundamental properties for these stars. We present long-baseline optical interferometry of five evolved intermediate-mass (∼ 1.5 M⊙) planet-hosting stars using the PAVO beam combiner at the CHARA Array, which we combine with bolometric flux measurements and parallaxes to determine their radii and effective temperatures. We measured the radii and effective temperatures of 6 Lyncis (5.12 ± 0.16 R⊙, 4949 ± 58 K), 24 Sextantis (5.49 ± 0.18 R⊙, 4908 ± 65 K), κ Coronae Borealis (4.77 ± 0.07 R⊙, 4870 ± 47 K), HR 6817 (4.45 ± 0.08 R⊙, 5013 ± 59 K), and HR 8461 (4.91 ± 0.12 R⊙, 4950 ± 68 K). We find disagreements of typically 15 per cent in angular diameter and ∼200 K in temperature compared to interferometric measurements in the literature, yet good agreement with spectroscopic and photometric temperatures, concluding that the previous interferometric measurements may have been affected by systematic errors exceeding their formal uncertainties. Modelling based on BaSTI isochrones using various sets of asteroseismic, spectroscopic, and interferometric constraints tends to favour slightly (∼15 per cent) lower masses than generally reported in the literature.Funding for the Stellar Astrophysics Centre is provided by The
Danish National Research Foundation. The research was supported
by the ASTERISK project (ASTERoseismic Investigations with
SONG and Kepler) funded by the European Research Council
(Grant agreement no.: 267864). TRW and VSA acknowledge the support of the Villum Foundation (research grant 10118). DH acknowledges
support by the Australian Research Council’s Discovery
Projects funding scheme (project number DE140101364) and
support by the NASA Grant NNX14AB92G issued through the
Kepler Participating Scientist Program. LC is supported by the
Australian Research Council Future Fellowship FT160100402. MJI
was supported by the Australian Research Council Future Fellowship
FT130100235. Parts of this research were conducted by the
Australian Research Council Centre of Excellence for All Sky Astrophysics
in 3 Dimensions (ASTRO 3D), through project number
CE170100013
- …