148 research outputs found

    Curcumin-loaded zeolite as anticancer drug carrier: Effect of curcumin adsorption on zeolite structure

    Get PDF
    In this work we used a combination of different techniques to investigate the adsorption properties of curcumin by zeolite type A for potential use as an anticancer drug carrier. Curcumin is a natural water-insoluble drug that has attracted great attention in recent years due to its potential anticancer effect in suppressing many types of cancers, while showing a synergistic antitumor effect with other anticancer agents. However, curcumin is poorly soluble in aqueous solutions leading to the application of high drug dosage in oral formulations. Zeolites, inorganic crystalline aluminosilicates with porous structure on the nano- and micro-scale and high internal surface area, can be useful as pharmaceutical carrier systems to encapsulate drugs with intrinsic low aqueous solubility and improve their dissolution. Here, we explore the use of zeolite type A for encapsulation of curcumin, and we investigate its surface properties and morphology, before and after loading of the anticancer agent, using scanning electron microscopy (SEM), powder X-ray diffraction (XRD), differential scanning calorimetry (DSC), and UV-vis spectroscopy. Results are used to assess the loading efficiency of zeolite type A towards curcumin and its structural stability after loading

    RIFT process analysis for the production of green composites in flax fibers and bio-based epoxy resin

    Get PDF
    In this work, a dual objective is carried out on composite materials in flax fiber and bio-based epoxy resin: to determine the process parameters and to develop a numerical model for highlighting the potential of and the limits in the production of “green” laminates through a RIFT process (Resin Infusion under Flexible Tool). For these reasons, compressibility tests were performed in order to evaluate the behavior of commercial flax woven under the vacuum bag. Subsequently, permeability tests were performed in order to evaluate the permeability curves necessary for the numerical study of the infusion process. For the numerical analyses, the commercial software PAM-RTM was adopted and validated. In this work, vaseline oil was used as the injected resin for the validation, and a bio-based epoxy commercial system was used for the study of the infusion process in a simple case study. The results were compared with a petroleum-based epoxy system typically used for infusion processes, showing the potentiality and the critical use of bio-based resins for infusion processes

    In Situ Monitoring of the Catalytic Activity of Cytochrome c Oxidase in a Biomimetic Architecture

    Get PDF
    AbstractCytochrome c oxidase (CcO) from Paracoccus denitrificans was immobilized in a strict orientation via a his-tag attached to subunit I on a gold film and reconstituted in situ into a protein-tethered bilayer lipid membrane. In this orientation, the cytochrome c (cyt c) binding site is directed away from the electrode pointing to the outer side of the protein-tethered bilayer lipid membrane architecture. The CcO can thus be activated by cyt c under aerobic conditions. Catalytic activity was monitored by impedance spectroscopy, as well as cyclic voltammetry. Cathodic and anodic currents of the CcO with cyt c added to the bulk solution were shown to increase under aerobic compared to anaerobic conditions. Catalytic activity was considered in terms of repeated electrochemical oxidation/reduction of the CcO/cyt c complex in the presence of oxygen. The communication of cyt c bound to the CcO with the electrode is discussed in terms of a hopping mechanism through the redox sites of the enzyme. Simulations supporting this hypothesis are included

    A study of asymmetric tensile properties of large area GEM foil

    Get PDF
    Gas Electron Multiplier (GEM) technology is being used in various applications, particularly in high energy physics experiments. The GEM is known as a reliable detector in high radiation environment which can maintain high temporal and position resolution. GEM foil is the basic part of the detector which consists of a composite material (polyimide and copper). Large size GEM foil has complex mechanical structure and asymmetries which mainly arises due to formation of the HV sectors in the foil. These asymmetries become very relevant when large size foils are stretched to build a detector. In this article asymmetry affects are presented that define the tensile properties of a large size segmented GEM foil

    Switching Transport through Nanopores with pH-Responsive Polymer Brushes for Controlled Ion Permeability

    Get PDF
    Several nanoporous platforms were functionalized with pH-responsive poly(methacrylic acid) (PMAA) brushes using surface-initiated atom transfer radical polymerization (SI-ATRP). The growth of the PMAA brush and its pH-responsive behavior from the nanoporous platforms were confirmed by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, and atomic force microscopy (AFM). The swelling behavior of the pH-responsive PMAA brushes grafted only from the nanopore walls was investigated by AFM in aqueous liquid environment with pH values of 4 and 8. AFM images displayed open nanopores at pH 4 and closed ones at pH 8, which rationalizes their use as gating platforms. Ion conductivity across the nanopores was investigated with current–voltage measurements at various pH values. Enhanced higher resistance across the nanopores was observed in a neutral polymer brush state (lower pH values) and lower resistance when the brush was charged (higher pH values). By adding a fluorescent dye in an environment of pH 4 or pH 8 at one side of the PMAA-brush functionalized nanopore array chips, diffusion across the nanopores was followed. These experiments displayed faster diffusion rates of the fluorescent molecules at pH 4 (PMAA neutral state, open pores) and slower diffusion at pH 8 (PMAA charged state, closed pores) showing the potential of this technology toward nanoscale valve applications

    Improving the cleanliness of graphene grown on copper by chemical vapor deposition for biosensing applications

    Get PDF
    Since graphene (G) was first isolated by mechanical exfoliation, several methods have been explored for producing G, in order to exploit its extraordinary properties in many applications, including biomedical and biosensing ones. G preparation methods should be selected according to the specific sensing target and mechanism to be utilized, with a balanced consideration on performances (e.g., detection limit and dynamic range), reproducibility, cost and manufacturability. For a wide range of biomedical and biosensing applications, the chemical vapor deposition (CVD) method is considered to be the most promising approach to synthesize large-area, high-quality G, with material properties approaching the theoretical predictions. It is expected that CVD-G will exhibit fascinating electrochemical properties, including wide electrochemical potential windows and low charge-transfer resistance, which can enable the study and exploitation of redox-active biological processes from new perspectives. In our work, we investigate the fabrication of electrochemical biosensors in which G has the role of the transducer and the biosensing element is a redox-active membrane protein embedded in a supported lipid bilayer (SLB) mimicking the cell membrane

    Facile formation of highly mobile supported lipid bilayers on surface-quaternized pH-responsive polymer brushes

    Get PDF
    Poly(2-dimethylamino)ethyl methacrylate) (PDMA) brushes are grown from planar substrates via surface atom transfer radical polymerization (ATRP). Quaternization of these brushes is conducted using 1-iodooctadecane in n-hexane, which is a non-solvent for PDMA. Ellipsometry, AFM, and water contact angle measurements show that surface-confined quaternization occurs under these conditions, producing pH-responsive brushes that have a hydrophobic upper surface. Systematic variation of the 1-iodooctadecane concentration and reaction time enables the mean degree of surface quaternization to be optimized. Relatively low degrees of surface quaternization (ca. 10 mol % as judged by XPS) produce brushes that enable the formation of supported lipid bilayers, with the hydrophobic pendent octadecyl groups promoting in situ rupture of lipid vesicles. Control experiments confirm that quaternized PDMA brushes prepared in a good brush solvent (THF) produce non-pH-responsive brushes, presumably because the pendent octadecyl groups form micelle-like physical cross-links throughout the brush layer. Supported lipid bilayers (SLBs) can also be formed on the non-quaternized PDMA precursor brushes, but such structures proved to be unstable to small changes in pH. Thus, surface quaternization of PDMA brushes using 1-iodooctadecane in n-hexane provides the best protocol for the formation of robust SLBs. Fluorescence recovery after photobleaching (FRAP) studies of such SLBs indicate diffusion coefficients (2.8 ± 0.3 μm s–1) and mobile fractions (98 ± 2%) that are comparable to the literature data reported for SLBs prepared directly on planar glass substrates

    30-day morbidity and mortality of sleeve gastrectomy, Roux-en-Y gastric bypass and one anastomosis gastric bypass: a propensity score-matched analysis of the GENEVA data

    Get PDF
    Background: There is a paucity of data comparing 30-day morbidity and mortality of sleeve gastrectomy (SG), Roux-en-Y gastric bypass (RYGB), and one anastomosis gastric bypass (OAGB). This study aimed to compare the 30-day safety of SG, RYGB, and OAGB in propensity score-matched cohorts. Materials and methods: This analysis utilised data collected from the GENEVA study which was a multicentre observational cohort study of bariatric and metabolic surgery (BMS) in 185 centres across 42 countries between 01/05/2022 and 31/10/2020 during the Coronavirus Disease-2019 (COVID-19) pandemic. 30-day complications were categorised according to the Clavien–Dindo classification. Patients receiving SG, RYGB, or OAGB were propensity-matched according to baseline characteristics and 30-day complications were compared between groups. Results: In total, 6770 patients (SG 3983; OAGB 702; RYGB 2085) were included in this analysis. Prior to matching, RYGB was associated with highest 30-day complication rate (SG 5.8%; OAGB 7.5%; RYGB 8.0% (p = 0.006)). On multivariate regression modelling, Insulin-dependent type 2 diabetes mellitus and hypercholesterolaemia were associated with increased 30-day complications. Being a non-smoker was associated with reduced complication rates. When compared to SG as a reference category, RYGB, but not OAGB, was associated with an increased rate of 30-day complications. A total of 702 pairs of SG and OAGB were propensity score-matched. The complication rate in the SG group was 7.3% (n = 51) as compared to 7.5% (n = 53) in the OAGB group (p = 0.68). Similarly, 2085 pairs of SG and RYGB were propensity score-matched. The complication rate in the SG group was 6.1% (n = 127) as compared to 7.9% (n = 166) in the RYGB group (p = 0.09). And, 702 pairs of OAGB and RYGB were matched. The complication rate in both groups was the same at 7.5 % (n = 53; p = 0.07). Conclusions: This global study found no significant difference in the 30-day morbidity and mortality of SG, RYGB, and OAGB in propensity score-matched cohorts
    • …
    corecore