342 research outputs found
Non Equilibrium Electronic Distribution in Single Electron Devices
The electronic distribution in devices with sufficiently small diemnsions may
not be in thermal equilibrium with their surroundings. Systems where the
occupancies of electronic states are solely determined by tunneling processes
are analyzed. It is shown that the effective temperature of the device may be
higher, or lower, than that of its environment, depending on the applied
voltage and the energy dependence of the tunneling rates. The I-V
characteristics become asymmetric. Comparison with recent experiments is made
Fluctuation theorem for currents and Schnakenberg network theory
A fluctuation theorem is proved for the macroscopic currents of a system in a
nonequilibrium steady state, by using Schnakenberg network theory. The theorem
can be applied, in particular, in reaction systems where the affinities or
thermodynamic forces are defined globally in terms of the cycles of the graph
associated with the stochastic process describing the time evolution.Comment: new version : 16 pages, 1 figure, to be published in Journal of
Statistical Physic
Charge Solitons in 1-D Arrays of Serially Coupled Josephson Junctions
We study a 1-D array of Josephson coupled superconducting grains with kinetic
inductance which dominates over the Josephson inductance. In this limit the
dynamics of excess Cooper pairs in the array is described in terms of charge
solitons, created by polarization of the grains. We analyze the dynamics of
these topological excitations, which are dual to the fluxons in a long
Josephson junction, using the continuum sine-Gordon model. We find that their
classical relativistic motion leads to saturation branches in the I-V
characteristic of the array. We then discuss the semi-classical quantization of
the charge soliton, and show that it is consistent with the large kinetic
inductance of the array. We study the dynamics of a quantum charge soliton in a
ring-shaped array biased by an external flux through its center. If the
dephasing length of the quantum charge soliton is larger than the circumference
of the array, quantum phenomena like persistent current and coherent current
oscillations are expected. As the characteristic width of the charge soliton is
of the order of 100 microns, it is a macroscopic quantum object. We discuss the
dephasing mechanisms which can suppress the quantum behaviour of the charge
soliton.Comment: 26 pages, LaTex, 7 Postscript figure
Nipah Virus Infection in Dogs, Malaysia, 1999
The 1999 outbreak of Nipah virus encephalitis in humans and pigs in Peninsular Malaysia ended with the evacuation of humans and culling of pigs in the epidemic area. Serologic screening showed that, in the absence of infected pigs, dogs were not a secondary reservoir for Nipah virus
Search for Correlations between HiRes Stereo Events and Active Galactic Nuclei
We have searched for correlations between the pointing directions of
ultrahigh energy cosmic rays observed by the High Resolution Fly's Eye
experiment and Active Galactic Nuclei (AGN) visible from its northern
hemisphere location. No correlations, other than random correlations, have been
found. We report our results using search parameters prescribed by the Pierre
Auger collaboration. Using these parameters, the Auger collaboration concludes
that a positive correlation exists for sources visible to their southern
hemisphere location. We also describe results using two methods for determining
the chance probability of correlations: one in which a hypothesis is formed
from scanning one half of the data and tested on the second half, and another
which involves a scan over the entire data set. The most significant
correlation found occurred with a chance probability of 24%.Comment: 13 pages, 1 table, 5 figure
Novel bleeding risk score for patients with atrial fibrillation on oral anticoagulants, including direct oral anticoagulants
Objective: Balancing bleeding risk and stroke risk in patients with atrial fibrillation (AF) is a common challenge. Though several bleeding risk scores exist, most have not included patients on direct oral anticoagulants (DOACs). We aimed at developing a novel bleeding risk score for patients with AF on oral anticoagulants (OAC) including both vitamin K antagonists (VKA) and DOACs. Methods: We included patients with AF on OACs from a prospective multicenter cohort study in Switzerland (SWISS-AF). The outcome was time to first bleeding. Bleeding events were defined as major or clinically relevant non-major bleeding. We used backward elimination to identify bleeding risk variables. We derived the score using a point score system based on the β-coefficients from the multivariable model. We used the Brier score for model calibration (<0.25 indicating good calibration), and Harrel's c-statistics for model discrimination. Results: We included 2147 patients with AF on OAC (72.5% male, mean age 73.4 ± 8.2 years), of whom 1209 (56.3%) took DOACs. After a follow-up of 4.4 years, a total of 255 (11.9%) bleeding events occurred. After backward elimination, age > 75 years, history of cancer, prior major hemorrhage, and arterial hypertension remained in the final prediction model. The Brier score was 0.23 (95% confidence interval [CI] 0.19–0.27), the c-statistic at 12 months was 0.71 (95% CI 0.63–0.80). Conclusion: In this prospective cohort study of AF patients and predominantly DOAC users, we successfully derived a bleeding risk prediction model with good calibration and discrimination
On Uniqueness of the Jump Process in Quantum Measurement Theory
We prove that, contrary to the standard quantum theory of continuous
observation, in the formalism of Event Enhanced Quantum Theory the stochastic
process generating individual sample histories of pairs (observed quantum
system, observing classical apparatus) is unique. This result gives a rigorous
basis to the previous heuristic argument of Blanchard and Jadczyk. Possible
implications of this result are discussed.Comment: 31 pages, LaTeX, article; e-mail contact [email protected]
Zero Frequency Current Noise for the Double Tunnel Junction Coulomb Blockade
We compute the zero frequency current noise numerically and in several limits
analytically for the coulomb blockade problem consisting of two tunnel
junctions connected in series. At low temperatures over a wide range of
voltages, capacitances, and resistances it is shown that the noise measures the
variance in the number of electrons in the region between the two tunnel
junctions. The average current, on the other hand, only measures the mean
number of electrons. Thus, the noise provides additional information about
transport in these devices which is not available from measuring the current
alone.Comment: 33 pages, 10 figure
- …