1,576 research outputs found

    The use of rapid prototyping techniques (RPT) to manufacture micro channels suitable for high operation pressures and uPIV

    Get PDF
    This paper aims to present a new methodology to manufacture micro-channels suitable for high operating pressures and micro particle image velocimetry (µPIV) measurements using a rapid-prototyping high-resolution 3D printer. This methodology can fabricate channels down to 250 µm and withstand pressures of up to 5 ± 0.2 MPa. The manufacturing times are much shorter than in soft lithography processes. The novel manufacturing method developed takes advantage of the recently improved resolution in 3D printers to manufacture an rapid prototyping technique part that contains the hose connections and a micro-channel useful for microfluidics. A method to assemble one wall of the micro-channel using UV curable glue with a glass slide is presented – an operation required to prepare the channel for µPIV measurements. Once built, the micro-channel has been evaluated when working under pressure and the grease flow behavior in it has been measured using µPIV. Furthermore, the minimum achievable channels have been defined using a confocal microscopy study. This technique is much faster than previous micro-manufacturing techniques where different steps were needed to obtain the micro-machined parts. However, due to current 3D printers ' resolutions (around 50 µm) and according to the experimental results, channels smaller than 250-µm2 cross-section should not be used to characterize fluid flow behaviors, as inaccuracies in the channel boundaries can deeply affect the fluid flow behavior. The present methodology is developed due to the need to validate micro-channels using µPIV to lubricate critical components (bearings and gears) in wind turbines. This novel micro-manufacturing technique overcomes current techniques, as it requires less manufacturing steps and therefore it is faster and with less associated costs to manufacture micro-channels down to 250-µm2 cross-section that can withstand pressures higher than 5 MPa that can be used to characterize microfluidic flow behavior using µPIV.Peer ReviewedPostprint (author's final draft

    Significació de la troponina en el diagnòstic de l'infart agut de miocardi

    Get PDF

    Charge and mass effects on the evaporation of higher-dimensional rotating black holes

    Full text link
    To study the dynamics of discharge of a brane black hole in TeV gravity scenarios, we obtain the approximate electromagnetic field due to the charged black hole, by solving Maxwell's equations perturbatively on the brane. In addition, arguments are given for brane metric corrections due to backreaction. We couple brane scalar and brane fermion fields with non-zero mass and charge to the background, and study the Hawking radiation process using well known low energy approximations as well as a WKB approximation in the high energy limit. We argue that contrary to common claims, the initial evaporation is not dominated by fast Schwinger discharge.Comment: Published version. Minor typos corrected. 29 pages, 5 figure

    Validation of a Microwave-Assisted Derivatization Gas Chromatography-Mass Spectrometry Method for the Quantification of 2-Hydroxybutyrate in Human Serum as an Early Marker of Diabetes Mellitus

    Full text link
    Circulating levels of 2-hydroxybutyrate (2HB) are highly related to glycemic status in different metabolomic studies. According to recent evidence, 2HB is an early biomarker of the future development of dysglycemia and type 2 diabetes mellitus and may be causally related to the progression of normal subjects to impaired fasting glucose or insulin resistance. In the present study, we developed and validated a simple, specific and sensitive gas chromatography-mass spectrometry (GC-MS) method specifically intended to quantify serum levels of 2HB. Liquid-liquid extraction with ethyl acetate was followed by 2 min of microwave-assisted derivatization. The method presented acceptable accuracy, precision and recovery, and the limit of quantification was 5 µM. Levels of 2HB were found to be stable in serum after three freeze-thaw cycles, and at ambient temperature and at a temperature of 4 °C for up to 24 h. Extracts derivatized under microwave irradiation were stable for up to 96 h. No differences were found in 2HB concentrations measured in serum or plasma EDTA samples. In summary, the method is useful for a rapid, precise and accurate quantification of 2HB in serum samples assessed for the evaluation of dysglycemia and diabetes mellitus

    Simulated Annealing, High-Order Statistics and Mutual Information for Separation of Sources

    Get PDF
    In this article, the fusion of a stochastic metaheuristic as Simulated Annealing (SA) with classical criteria for convergence of Blind Separation of Sources (BSS), is shown. Although the topic of BSS, by means of various techniques, including ICA, PCA, and neural networks, has been amply discussed in the literature, to date the possibility of using simulated annealing algorithms has not been seriously explored. From experimental results, this paper demonstrates the possible benefits offered by SA in combination with high order statistical and mutual information criteria for BSS, such as robustness against local minima and a high degree of flexibility in the energy function

    New method for lubricating wind turbine pitch gears using embedded micro-nozzles

    Get PDF
    This is a copy of the author 's final draft version of an article published in the journal Journal of mechanical science and technology. The final publication is available at Springer via http://dx.doi.org/10.1007/s12206-017-0131-3The increase of power generated by wind turbines has increased the stresses applied in all of its components, thereby causing premature failures. Particularly, pitch and yaw gears suffer from excessive wear mainly caused by inappropriate lubrication. This paper presents a novel method to automatically lubricate the wind turbine pitch gear during operation. A micro-nozzle to inject fresh grease continuously between the teeth in contact was designed, manufactured, and installed in a test bench of a 2 MW wind turbine pitch system. The test bench was used to characterize the fatigue behavior of the gear surface using conventional wind turbine greases under real cyclic loads. Measurements of wear evolution in a pitch gear with and without micro-nozzle show a decrease of 70 % of the wear coefficient after 2×104 cycles.Peer ReviewedPostprint (author's final draft

    Rotating Black Holes at Future Colliders. III. Determination of Black Hole Evolution

    Full text link
    TeV scale gravity scenario predicts that the black hole production dominates over all other interactions above the scale and that the Large Hadron Collider will be a black hole factory. Such higher dimensional black holes mainly decay into the standard model fields via the Hawking radiation whose spectrum can be computed from the greybody factor. Here we complete the series of our work by showing the greybody factors and the resultant spectra for the brane localized spinor and vector field emissions for arbitrary frequencies. Combining these results with the previous works, we determine the complete radiation spectra and the subsequent time evolution of the black hole. We find that, for a typical event, well more than half a black hole mass is emitted when the hole is still highly rotating, confirming our previous claim that it is important to take into account the angular momentum of black holes.Comment: typoes in eqs(82)-(84) corrected; version to appear in Phys. Rev. D; references and a footnote added; same manuscript with high resolution embedded figures available on http://www.gakushuin.ac.jp/univ/sci/phys/ida/paper

    Missing energy in black hole production and decay at the Large Hadron Collider

    Full text link
    Black holes could be produced at the Large Hadron Collider in TeV-scale gravity scenarios. We discuss missing energy mechanisms in black hole production and decay in large extra-dimensional models. In particular, we examine how graviton emission into the bulk could give the black hole enough recoil to leave the brane. Such a perturbation would cause an abrupt termination in Hawking emission and result in large missing-energy signatures.Comment: addressed reviewer comments and updated reference

    The Integration of Nanomedicine with Traditional Chinese Medicine: Drug Delivery of Natural Products and Other Opportunities

    Full text link
    The integration of progressive technologies such as nanomedicine with the use of natural products from traditional medicine (TM) provides a unique opportunity for the longed-for harmonization between traditional and modern medicine. Although several actions have been initiated decades ago, a disparity of reasons including some misunderstandings between each other limits the possibilities of a truly complementation. Herein, we analyze some common challenges between nanomedicine and traditional Chinese medicine (TCM). These challenges, if solved in a consensual way, can give a boost to such harmonization. Nanomedicine is a recently born technology, while TCM has been used by the Chinese people for thousands of years. However, for these disciplines, the regulation and standardization of many of the protocols, especially related to the toxicity and safety, regulatory aspects, and manufacturing procedures, are under discussion. Besides, both TCM and nanomedicine still need to achieve a wider social acceptance. Herein, we first briefly discuss the strengths and weaknesses of TCM. This analysis serves to focus afterward on the aspects where TCM and nanomedicine can mutually help to bridge the existing gaps between TCM and Western modern medicine. As discussed, many of these challenges can be applied to TM in general. Finally, recent successful cases in scientific literature that merge TCM and nanomedicine are reviewed as examples of the benefits of this harmonization
    corecore