ZnMoO4: a promising bolometer for neutrinoless double beta decay searches
We investigate the performances of two ZnMoO4 scintillating crystals operated
as bolometers, in view of a next generation experiment to search the
neutrinoless double beta decay of Mo-100. We present the results of the alpha
vs beta/gamma discrimination, obtained through the scintillation light as well
as through the study of the shape of the thermal signal alone. The
discrimination capability obtained at the 2615 keV line of Tl-208 is 8 sigma,
using the heat-light scatter plot, while it exceeds 20 sigma using the shape of
the thermal pulse alone. The achieved FWHM energy resolution ranges from 2.4
keV (at 238 keV) to 5.7 keV (at 2615 keV). The internal radioactive
contaminations of the ZnMoO4 crystals were evaluated through a 407 hours
background measurement. The obtained limit is < 32 microBq/kg for Th-228 and
Ra-226. These values were used for a Monte Carlo simulation aimed at evaluating
the achievable background level of a possible, future array of enriched ZnMoO4
crystals.Comment: 9 pages, 8 figure
Spot size measurements in the Eli-NP compton gamma source
A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32 bunches with a nominal charge of 250 pC and 16 ns spacing , will collide with the laser beam in the interaction point. Electron beam spot size is measured with an OTR (optical transition radiation) profile moni-tors. In order to measure the beam properties, the optical radiation detecting system must have the necessary accu-racy and resolution. This paper deals with the studies of different optic configurations to achieve the magnifica-tion, resolution and accuracy desired considering design and technological constraints; we will compare several configurations of the optical detection line to justify the one chosen for the implementation in the Lina
Intense terahertz pulses from SPARC-LAB coherent radiation source
The linac-based Terahertz source at the SPARC_LAB test facility is able to gene
rate highly intense Terahertz broadband
pulses
via
coherent transition radiation (CTR) from high brightness electron beams. The THz pulse duration is typically
down to 100 fs RMS and can be tuned through the electron bunch duration and shaping. The measured stored energy in a
single THz pulse has reached 40
ÎĽ
J, which corresponds to a peak
electric field of 1.6 MV/cm at the THz focus. Here we
present the main features, in particular spatial and sp
ectral distributions and energy
characterizations of the
SPARC_LAB THz source, which is very competitive for investigations in Condensed Matter, as well as a valid tool for
electron beam longitudinal diagnostics
Optical issues for the diagnostic stations for the ELI-NP compton gamma source
A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32 bunches, 16 ns spaced, with a nominal charge of 250 pC will collide with the laser beam in the interaction point. Electron beam spot size is measured with optical transition radiation (OTR) profile monitors. In order to measure the beam properties, the optical radiation detecting system must have the necessary accuracy and resolution. This paper deals with the studies of different optic configurations to achieve the magnification, resolution and accuracy in order to measure very small beam (below 30 ÎĽm) or to study the angular distribution of the OTR and therefore the energy of the beam. Several configurations of the optical detection line will be studied both with simulation tools (e.g. Zemax) and experimentally. The paper will deal also with the sensibility of optic system (in terms of depth of field, magnification and resolution) to systematic error
The machine protection system for the ELI-NP gamma beam system
The new Gamma Beam System (GBS) of the ELI-NPproject [1], currently under installation in Magurele (RO)by INFN, as part of EuroGammas consortium, can providegamma rays that open new possibilities for nuclear photonicsand nuclear physics.ELI-NP gamma rays are produced by Compton back-scattering to get monochromaticity (0,1% bandwidth), highflux (1013photons), tunable direction and energy up to19.5 MeV. Such gamma beam is obtained when a high-intensity laser collides a high-brightness electron beam withenergies up to740 MeV, a repetition rate of100 Hz, withtrains of 32 bunches within the same RF bucket.An advanced Machine Protection System (MPS) has beendeveloped, in order to ensure proper operation for this chal-lenging facility. The MPS operates on different layers of thecontrol system and is interfaced with all its sub-systems. Forinstance, it comprises different kind of beam loss monitors(based on Cherenkov optical fiber), hall probes, fast currenttransformer together with BPMs, and an embedded systembased on FPGA with distributed I/O over EtherCAT, to mon-itor vacuum and RF systems [2], which require fast responseto be interlocked within one RF pulse
TeO bolometers with Cherenkov signal tagging: towards next-generation neutrinoless double beta decay experiments
CUORE, an array of 988 TeO bolometers, is about to be one of the most
sensitive experiments searching for neutrinoless double-beta decay. Its
sensitivity could be further improved by removing the background from
radioactivity. A few years ago it has been pointed out that the signal from
s can be tagged by detecting the emitted Cherenkov light, which is not
produced by s. In this paper we confirm this possibility. For the first
time we measured the Cherenkov light emitted by a CUORE crystal, and found it
to be 100 eV at the -value of the decay. To completely reject the
background, we compute that one needs light detectors with baseline noise below
20 eV RMS, a value which is 3-4 times smaller than the average noise of the
bolometric light detectors we are using. We point out that an improved light
detector technology must be developed to obtain TeO bolometric experiments
able to probe the inverted hierarchy of neutrino masses.Comment: 5 pages, 4 figures. Added referee correction
Exploring a New Paradigm for Accelerators and Large Experimental Apparatus Control Systems
International audienceThe integration of web technologies and web services has been, in the recent years, one of the major trends in upgrading and developing control systems for accelerators and large experimental apparatuses. Usually, web technologies have been introduced to complement the control systems with smart add-ons and user friendly services or, for instance, to safely allow access to the control system to users from remote sites. In spite of this still narrow spectrum of employment, some software technologies developed for high performance web services, although originally intended and optimized for these particular applications, deserve some features that would allow their deeper integration in a control system and, eventually, use them to develop some of the control system's core components. In this paper we present the conclusion of the preliminary investigations of a new paradigm for an accelerator control system and associated machine data acquisition system (DAQ), based on a synergic combination of network distributed cache memory and a non-relational key/value database. We investigated these technologies with particular interest on performances, namely speed of data storage and retrieve for the network memory, data throughput and queries execution time for the database and, especially, how much this performances can benefit from their inherent scalability. The work has been developed in a collaboration between INFN-LNF and INFN-Roma Tor Vergata
New experimental limits on the alpha decays of lead isotopes
For the first time a PbWO4 crystal was grown using ancient Roman lead and it
was run as a cryogenic detector. Thanks to the simultaneous and independent
read-out of heat and scintillation light, the detector was able to discriminate
beta/gamma interactions with respect to alpha particles down to low energies.
New more stringent limits on the alpha decays of the lead isotopes are
presented. In particular a limit of T_{1/2} > 1.4*10^20 y at a 90% C.L. was
evaluated for the alpha decay of 204Pb to 200Hg
- …