306 research outputs found
Rationale for windshield glass system specification requirements for shuttle orbiter
A preliminary procurement specification for the space shuttle orbiter windshield pane, and some of the design considerations and rationale leading to its development are presented. The windshield designer is given the necessary methods and procedures for assuring glass pane structural integrity by proof test. These methods and procedures are fully developed for annealed and thermally tempered aluminosilicate, borosilicate, and soda lime glass and for annealed fused silica. Application of the method to chemically tempered glass is considered. Other considerations are vision requirements, protection against bird impact, hail, frost, rain, and meteoroids. The functional requirements of the windshield system during landing, ferrying, boost, space flight, and entry are included
Recommended from our members
In vivo and in vitro assessment of mirtazapine pharmacokinetics in cats with liver disease.
BackgroundLiver disease (LD) prolongs mirtazapine half-life in humans, but it is unknown if this occurs in cats with LD and healthy cats.Hypothesis/objectivesTo determine pharmacokinetics of administered orally mirtazapine in vivo and in vitro (liver microsomes) in cats with LD and healthy cats.AnimalsEleven LD and 11 age-matched control cats.MethodsCase-control study. Serum was obtained 1 and 4 hours (22 cats) and 24 hours (14 cats) after oral administration of 1.88 mg mirtazapine. Mirtazapine concentrations were measured by liquid chromatography with tandem mass spectrometry. Drug exposure and half-life were predicted using limited sampling modeling and estimated using noncompartmental methods. in vitro mirtazapine pharmacokinetics were assessed using liver microsomes from 3 LD cats and 4 cats without LD.ResultsThere was a significant difference in time to maximum serum concentration between LD cats and control cats (median [range]: 4 [1-4] hours versus 1 [1-4] hours; P = .03). The calculated half-life of LD cats was significantly prolonged compared to controls (median [range]: 13.8 [7.9-61.4] hours versus 7.4 [6.7-9.1] hours; P < .002). Mirtazapine half-life was correlated with ALT (P = .002; r = .76), ALP (P < .0001; r = .89), and total bilirubin (P = .0008; r = .81). The rate of loss of mirtazapine was significantly different between microsomes of LD cats (-0.0022 min-1 , CI: -0.0050 to 0.00054 min-1 ) and cats without LD (0.01849 min-1 , CI: -0.025 to -0.012 min-1 ; P = .002).Conclusions and clinical importanceCats with LD might require less frequent administration of mirtazapine than normal cats
Simulation studies and background measurements for a laser based beam size monitor for the future linear collider
At several locations of the beam delivery system (BDS) of a future linear collider (FLC), beam spot sizes ranging from several hundreds to a few micrometers have to be measured. It is anticipated that laser wires will be used for this task in any FLC design. In order to optimize a laser wire system, simulations and background measurements have been carried out. Results are presented from simulations of the Compton scattering for the PETRA scenario. Furthermore results from measurements of backgrounds like synchrotron radiation and gas scattering have been measured at the positron storage ring PETRA at DESY and will be discussed
Beam Profile Measurements and Simulations of the PETRA Laser-Wire
The Laser-wire will be an essential diagnostic tool at the International
Linear Collider. It uses a finely focussed laser beam to measure the transverse
profile of electron bunches by detecting the Compton-scattered photons (or
degraded electrons) downstream of where the laser beam intersects the electron
beam. Such a system has been installed at the PETRA storage ring at DESY, which
uses a piezo-driven mirror to scan the laser-light across the electron beam.
Lat- est results of experimental data taking are presented and compared to
detailed simulations using the Geant4 based program BDSIM.Comment: 3 pagesm 4 figures. Submitted as a conference paper for the Particle
Accelerator Conference 2005 (PAC05
Large aperture vibrating wire monitor with two mechanically coupled wires for beam halo measurements
Development of a new type of vibrating wire monitor (VWM), which has two mechanically coupled wires (vibrating and target), is presented. The new monitor has a much larger aperture size than the previous model of the VWM, and thus allows us to measure transverse beam halos more effectively. A prototype of such a large aperture VWM with a target wire length of 60 mm was designed, manufactured, and bench-tested. Initial beam measurements have been performed at the Fermilab High Intensity Neutrino Source facility, and key results are presented.open1
Laser Wire Scanner Compton Scattering Techniques for the Measurement of the Transverse Beam Size of Particle Beams at Future Linear Colliders
This archive summarizes a working paper and conference proceedings related to
laser wire scanner development for the Future Linear Collider (FLC) in the
years 2001 to 2006. In particular the design, setup and data taking for the
laser wire experiments at PETRA II and CT2 are described. The material is
focused on the activities undertaken by Royal Holloway University of London
(RHUL).Comment: 61 page
- …