    Novacor left ventricular assist system versus heartmate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients: A prospective study

    Get PDF
    AbstractObjective: Long-term mechanical circulatory support as a bridge-to-transplantation procedure and bridge to recovery is of increasing importance. The implantable left ventricular assist devices, Novacor N100 left ventricular assist system (Baxter Healthcare Corporation, Berkeley, Calif) and TCI HeartMate vented electric left ventricular assist system (Thermo Cardiosystems Inc, Woburn, Mass), have proved to be efficient devices in bridge-to-transplantation settings and for prolonged support. The two systems were compared with regard to reliability and morbidity. Methods: Between October 1996 and March 1998, a prospective, single-center study was done that included 40 patients, 20 of whom were treated with the Novacor system and 20 of whom were treated with the HeartMate device. The diseases were mainly dilated cardiomyopathy (13/9) and ischemic cardiomyopathy (6/10). There were no statistically significant differences between the two groups regarding age, sex, preoperative clinical blood chemistry values, hemodynamic data, or risk factors. Results: There were no statistically significant differences between the two groups with regard to postoperative hemodynamics, organ recovery, out-of-hospital support, and survival to heart transplantation. Mean duration of support was 235.3 ± 210 days for the Novacor group and 174.6 ± 175 days for the HeartMate group and mean out-of-hospital support was 241 ± 179 days and 166 ± 152 days for the two groups, respectively. Neurologic complications occurred significantly more often among the Novacor group, whereas the HeartMate group had a higher prevalence of infections and technical problems, which was statistically significant. Survival to transplantation was 65% for the Novacor group and 60% for the HeartMate group. Conclusions: Most patients had organ recovery with left ventricular assist system support, and a considerable number of patients in both groups underwent transplantation. However, both devices need revision to address the current problems, that is, thromboembolism for the Novacor device and infection and reliability for the HeartMate device. (J Thorac Cardiovasc Surg 2000;119:581-7

    Intra-abdominal hypertension due to heparin - induced retroperitoneal hematoma in patients with ventricle assist devices: report of four cases and review of the literature

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Elevated intra-abdominal pressure (IAP) has been identified as a cascade of pathophysiologic changes leading in end-organ failure due to decreasing compliance of the abdomen and the development of abdomen compartment syndrome (ACS). Spontaneous retroperitoneal hematoma (SRH) is a rare clinical entity seen almost exclusively in association with anticoagulation states, coagulopathies and hemodialysis; that may cause ACS among patients in the intensive care unit (ICU) and if treated inappropriately represents a high mortality rate.</p> <p>Case Presentation</p> <p>We report four patients (a 36-year-old Caucasian female, a 59-year-old White-Asian male, a 64-year-old Caucasian female and a 61-year-old Caucasian female) that developed an intra-abdominal hypertension due to heparin-induced retroperitoneal hematomas after implantation of ventricular assist devices because of heart failure. Three of the patients presented with dyspnea at rest, fatigue, pleura effusions in chest XR and increased heart rate although b-blocker therapy. A 36-year old female (the forth patient) presented with sudden, severe shortness of breath at rest, 10 days after an "acute bronchitis". At the time of the event in all cases international normalized ratio (INR) was <3.5 and partial thromboplastin time <65 sec. The patients were treated surgically, the large hematomas were evacuated and the systemic manifestations of the syndrome were reversed.</p> <p>Conclusion</p> <p>Identifying patients in the ICU at risk for developing ACS with constant surveillance can lead to prevention. ACS is the natural progression of pressure-induced end-organ changes and develops if IAP is not recognized and treated in a timely manner. Failure to recognize and appropriately treat ACS is fatal while timely intervention - if indicated - is associated with improvements in organ function and patient survival. Means for surgical decision making are based on clinical indicators of adverse physiology, rather than on a single measured parameter.</p

    K201 improves aspects of the contractile performance of human failing myocardium via reduction in Ca2+ leak from the sarcoplasmic reticulum

    Get PDF
    In heart failure, intracellular Ca2+ leak from cardiac ryanodine receptors (RyR2s) leads to a loss of Ca2+ from the sarcoplasmic reticulum (SR) potentially contributing to decreased function. Experimental data suggest that the 1,4-benzothiazepine K201 (JTV-519) may stabilise RyR2s and thereby reduce detrimental intracellular Ca2+ leak. Whether K201 exerts beneficial effects in human failing myocardium is unknown. Therefore, we have studied the effects of K201 on muscle preparations from failing human hearts. K201 (0.3 μM; extracellular [Ca2+]e 1.25 mM) showed no effects on contractile function and micromolar concentrations resulted in negative inotropic effects (K201 1 μM; developed tension −9.8 ± 2.5% compared to control group; P < 0.05). Interestingly, K201 (0.3 μM) increased the post-rest potentiation (PRP) of failing myocardium after 120 s, indicating an increased SR Ca2+ load. At high [Ca2+]e concentrations (5 mmol/L), K201 increased PRP already at shorter rest intervals (30 s). Strikingly, treatment with K201 (0.3 μM) prevented diastolic dysfunction (diastolic tension at 5 mmol/L [Ca2+]e normalised to 1 mmol/L [Ca2+]e: control 1.26 ± 0.06, K201 1.01 ± 0.03, P < 0.01). In addition at high [Ca2+]e, K201 (0.3 μM) treatment significantly improved systolic function [developed tension +27 ± 8% (K201 vs. control); P < 0.05]. The beneficial effects on diastolic and systolic functions occurred throughout the physiological frequency range of the human heart rate from 1 to 3 Hz. Upon elevated intracellular Ca2+ concentration, systolic and diastolic contractile functions of terminally failing human myocardium are improved by K201

    Normothermic Ex Vivo Allograft Blood Perfusion in Clinical Heart Transplantation

    No full text
    Cold ischemia associated with cold static storage is an independent risk factor for primary allograft failure and survival of patients after orthotopic heart transplantation. The effects of normothermic ex vivo allograft blood perfusion on outcomes after orthotopic heart transplantation compared to cold static storage have been studied. In this prospective, nonrandomized, single-institutional clinical study, normothermic ex vivo allograft blood perfusion has been performed using an organ care system (OCS) (TransMedics, Andover, MA, USA). Included were consecutive adult transplantation patients who received an orthotopic heart transplantation (oHTx) without a history of any organ transplantation, in the absence of a congenital heart disorder as an underlying disease and not being in need of a combined heart-lung transplantation. Furthermore, patients with fixed pulmonary hypertension, ventilator dependency, chronic renal failure, or panel reactive antibodies >20% and positive T-cell cross-matching were excluded. Inclusion criteria for donor hearts was age of 85 mmHg at the time of final heart assessment under moderate inotropic support, heart rate of 40% assessed by an transcutaneous echo/Doppler study with the absence of gross wall motion abnormalities, absence of left ventricular hypertrophy, and absence of valve abnormalities. Donor hearts which were conventionally cold stored with histidine-tryptophan-ketoglutarate solution (Custodiol; Koehler Chemie, Ansbach, Germany) constituted the control group. The primary end point was the recipients' survival at 30 days and 1 and 2 years after their heart transplantation. Secondary end points were primary and chronic allograft failure, noncardiac complications, and length of hospital stay. Over a 2-year period (January 2006 to July 2008), 159 adult cardiac allografts were transplanted. Twenty-nine were assigned for normothermic ex vivo allograft blood perfusion and 130 for cold static storage with HTK solution. Cumulative survival rates at 30 days and 1 and 2 years were 96%, 89%, and 89%, respectively, whereas in the cold static storage group survival after oHTx was 95%, 81%, and 79%. Primary graft failure was less frequent in the recipients of an oHTx who received a donor heart which had been preserved with normothermic ex vivo allograft blood perfusion using an OCS (6.89% versus 15.3%; P = .20). Episodes of severe acute rejection (23% versus 17.2%; P = .73), as well as, cases of acute renal failure requiring haemodialysis (25.3% versus 10%; P = .05) were more frequent diagnosed among recipients of a donor heart which had been preserved using the cold static storage. The length of hospital stay did not differ (26 days versus 28 days; P = .80) in both groups. Normothermic ex vivo allograft blood perfusion in adult clinical orthotopic heart transplantation contributes to better outcomes after transplantation in regard to recipient survival, incidence of primary graft dysfunction, and incidence of acute rejection

    Economic evaluation of everolimus and mycophenolate mofetil versus azathioprine in de novo heart transplantation

    No full text
    Both the proliferation signal inhibitor everolimus (1.5 mg/day) and mycophenolate mofetil (MMF) (3 g/day) have shown superior efficacy versus azathioprine in de novo heart transplantation. The cost-effectiveness of everolimus and MMF versus azathioprine was assessed to 6 months posttransplantation. Methods. The evaluation was performed from the German health insurance payer perspective. The composite efficacy endpoint in the everolimus trial was death, graft loss/retransplantation, biopsy-proven acute rejection (BPAR) grade >= 3A, rejection with hemodynamic compromise, and loss to follow-up. The composite endpoint in the MMF trial included only death, retransplantation, and BPAR with hemodynamic compromise. To mimic the everolimus endpoint, an estimated number of patients with BPAR >= 3A was added to the MMF trial results, using two mapping scenarios. Results. The incremental 6-month cost versus azathioprine was (sic)2535 for everolimus and (sic)3007 for MMF. The absolute reduction in efficacy failure versus azathioprine was 10.4% for everolimus and 9.8% and 10.1% for MMF, respectively, using scenarios 1 and 2. The incremental cost per efficacy failure avoided (ie, the incremental cost versus azathioprine divided by the reduction in efficacy failure) was (sic)24,457 for everolimus, and (sic)30,628 and (sic)29,912 for MMF in scenarios 1 and 2. Conclusion. This analysis, based on findings from two clinical trials, suggested that everolimus was more cost-effective than MMF versus azathioprine in the first 6 months after heart transplantation. Data from a head-to-head trial are required to confirm these results