99 research outputs found

    Measurement of the radiative decay of polarized muons in the MEG experiment

    Get PDF
    We studied the radiative muon decay μ+e+ννˉγ\mu^+ \to e^+\nu\bar{\nu}\gamma by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B(μ+e+ννˉγ\mu^+ \to e^+\nu\bar{\nu}\gamma) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_{\gamma} > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for μ+e+γ\mu^+ \to e^+\gamma process.Comment: 8 pages, 7 figures. Added an introduction to NLO calculation which was recently calculated. Published versio

    Muon polarization in the MEG experiment: Predictions and measurements

    Get PDF
    The MEG experiment makes use of one of the world’s most intense low energy muon beams, in order to search for the lepton flavour violating process μ+ → e+ γ. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be Pμ = −1 by the StandardModel (SM) with massless neutrinos. We estimated our residual muon polarization to be (formula presented) at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our μ+ → e+ γ search induced by themuon radiative decay: (formula presented)

    Measurement of the radiative decay of polarized muons in the MEG experiment

    Get PDF
    We studied the radiative muon decay (Formula presented.) by using for the first time an almost fully polarized muon source. We identified a large sample ((Formula presented.) 13,000) of these decays in a total sample of (Formula presented.) positive muon decays collected in the MEG experiment in the years 2009–2010 and measured the branching ratio (Formula presented.) for (Formula presented.) and (Formula presented.) , consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for (Formula presented.) process

    Search for the lepton flavour violating decay μ+→ e +γ with the full dataset of the MEG experiment: MEG Collaboration

    Get PDF
    The final results of the search for the lepton flavour violating decay μ+→ e +γ based on the full dataset collected by the MEG experiment at the Paul Scherrer Institut in the period 2009–2013 and totalling 7.5 × 10 14 stopped muons on target are presented. No significant excess of events is observed in the dataset with respect to the expected background and a new upper limit on the branching ratio of this decay of B(μ+→ e +γ) < 4.2 × 10 - 13 (90 % confidence level) is established, which represents the most stringent limit on the existence of this decay to date

    Search for the lepton flavour violating decay μ+→ e +γ with the full dataset of the MEG experiment: MEG Collaboration

    Get PDF
    none84siThe final results of the search for the lepton flavour violating decay mu(+) -> e(+)gamma based on the full dataset collected by the MEG experiment at the Paul Scherrer Institut in the period 2009-2013 and totalling 7.5x10(14) stopped muons on target are presented. Nosignificant excess of events is observed in the dataset with respect to the expected background and a new upper limit on the branching ratio of this decay of B(mu(+) -> e(+) gamma) < 4.2 x 10(-13) (90 % confidence level) is established, which represents the most stringent limit on the existence of this decay to date.Baldini, A.M.; Bao, Y.; Baracchini, E.; Bemporad, C.; Berg, F.; Biasotti, M.; Boca, G.; Cascella, M.; Cattaneo, P.W.; Cavoto, G.; Cei, F.; Cerri, C.; Chiarello, G.; Chiri, C.; Corvaglia, A.; de Bari, A.; De Gerone, M.; Doke, T.; D’Onofrio, A.; Dussoni, S.; Egger, J.; Fujii, Y.; Galli, L.; Gatti, F.; Grancagnolo, F.; Grassi, M.; Graziosi, A.; Grigoriev, D.N.; Haruyama, T.; Hildebrandt, M.; Hodge, Z.; Ieki, K.; Ignatov, F.; Iwamoto, T.; Kaneko, D.; Kang, T.I.; Kettle, P.-R.; Khazin, B.I.; Khomutov, N.; Korenchenko, A.; Kravchuk, N.; Lim, G.M.A.; Maki, A.; Mihara, S.; Molzon, W.; Mori, Toshinori; Morsani, F.; Mtchedilishvili, A.; Mzavia, D.; Nakaura, S.; Nardò, R.; Nicolò, D.; Nishiguchi, H.; Nishimura, M.; Ogawa, S.; Ootani, W.; Orito, S.; Panareo, M.; Papa, A.; Pazzi, R.; Pepino, A.; Piredda, G.; Pizzigoni, G.; Popov, A.; Raffaelli, F.; Renga, F.; Ripiccini, E.; Ritt, S.; Rossella, M.; Rutar, G.; Sawada, R.; Sergiampietri, F.; Signorelli, G.; Simonetta, M.; Tassielli, G.F.; Tenchini, F.; Uchiyama, Y.; Venturini, M.; Voena, C.; Yamamoto, A.; Yoshida, K.; You, Z.; Yudin, Yu. V.; Zanello, D.Baldini, A. M.; Bao, Y.; Baracchini, E.; Bemporad, C.; Berg, F.; Biasotti, M.; Boca, Gianluigi; Cascella, M.; Cattaneo, P. W.; Cavoto, G.; Cei, F.; Cerri, C.; Chiarello, G.; Chiri, C.; Corvaglia, A.; DE BARI, Antonio; De Gerone, M.; Doke, T.; D’Onofrio, A.; Dussoni, S.; Egger, J.; Fujii, Y.; Galli, L.; Gatti, F.; Grancagnolo, F.; Grassi, M.; Graziosi, A.; Grigoriev, D. N.; Haruyama, T.; Hildebrandt, M.; Hodge, Z.; Ieki, K.; Ignatov, F.; Iwamoto, T.; Kaneko, D.; Kang, T. I.; Kettle, P. R.; Khazin, B. I.; Khomutov, N.; Korenchenko, A.; Kravchuk, N.; Lim, G. M. A.; Maki, A.; Mihara, S.; Molzon, W.; Mori, Toshinori; Morsani, F.; Mtchedilishvili, A.; Mzavia, D.; Nakaura, S.; Nardo', Roberto; Nicolò, D.; Nishiguchi, H.; Nishimura, M.; Ogawa, S.; Ootani, W.; Orito, S.; Panareo, M.; Papa, A.; Pazzi, R.; Pepino, A.; Piredda, G.; Pizzigoni, G.; Popov, A.; Raffaelli, F.; Renga, F.; Ripiccini, E.; Ritt, S.; Rossella, M.; Rutar, G.; Sawada, R.; Sergiampietri, F.; Signorelli, G.; Simonetta, M.; Tassielli, G. F.; Tenchini, F.; Uchiyama, Y.; Venturini, M.; Voena, C.; Yamamoto, A.; Yoshida, K.; You, Z.; Yudin, Y. u. V.; Zanello, D

    Technical design of the phase I Mu3e experiment

    Get PDF
    The Mu3e experiment aims to find or exclude the lepton flavour violating decay μ→eee at branching fractions above 10−16. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of 2⋅10−15. We present an overview of all aspects of the technical design and expected performance of the phase I Mu3e detector. The high rate of up to 108 muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements

    Radioimmunotherapy of B-cell lymphoma with radiolabelled anti-CD20 monoclonal antibodies

    Get PDF
    CD20 has proven to be an excellent target for the treatment of B-cell lymphoma, first for the chimeric monoclonal antibody rituximab (Rituxan™), and more recently for the radiolabelled antibodies Y-90 ibritumomab tiuxetan (Zevalin™) and I-131 tositumomab (Bexxar™). Radiation therapy effects are due to beta emissions with path lengths of 1–5 mm; gamma radiation emitted by I-131 is the only radiation safety issue for either product. Dose-limiting toxicity for both radiolabelled antibodies is reversible bone marrow suppression. They produce response rates of 70%–90% in low-grade and follicular lymphoma and 40%–50% in transformed low-grade or intermediate-grade lymphomas. Both products produce higher response rates than related unlabelled antibodies, and both are highly active in patients who are relatively resistant to rituximab-based therapy. Median duration of response to a single course of treatment is about 1 year with complete remission rates that last 2 years or longer in about 25% of patients. Clinical trials suggest that anti- CD20 radioimmunotherapy is superior to total body irradiation in patients undergoing stem cell supported therapy for B-cell lymphoma, and that it is a safe and efficacious modality when used as consolidation therapy following chemotherapy. Among cytotoxic treatment options, current evidence suggests that one course of anti-CD20 radioimmunotherapy is as efficacious as six to eight cycles of combination chemotherapy. A major question that persists is how effective these agents are in the setting of rituximab- refractory lymphoma. These products have been underutilised because of the complexity of treatment coordination and concerns regarding reimbursement

    Survival of atraumatic restorative treatment (ART) sealants and restorations: a meta-analysis

    Get PDF
    The purpose of this study is to perform a systematic investigation plus meta-analysis into survival of atraumatic restorative treatment (ART) sealants and restorations using high-viscosity glass ionomers and to compare the results with those from the 2005 ART meta-analysis. Until February 2010, four databases were searched. Two hundred four publications were found, and 66 reported on ART restorations or sealant survival. Based on five exclusion criteria, two independent reviewers selected the 29 publications that accounted for the meta-analysis. Confidence intervals (CI) and or standard errors were calculated and the heterogeneity variance of the survival rates was estimated. Location (school/clinic) was an independent variable. The survival rates of single-surface and multiple-surface ART restorations in primary teeth over the first 2 years were 93% (CI, 91–94%) and 62% (CI, 51–73%), respectively; for single-surface ART restorations in permanent teeth over the first 3 and 5 years it was 85% (CI, 77–91%) and 80% (CI, 76–83%), respectively and for multiple-surface ART restorations in permanent teeth over 1 year it was 86% (CI, 59–98%). The mean annual dentine lesion incidence rate, in pits and fissures previously sealed using ART, over the first 3 years was 1%. No location effect and no differences between the 2005 and 2010 survival rates of ART restorations and sealants were observed. The short-term survival rates of single-surface ART restorations in primary and permanent teeth, and the caries-preventive effect of ART sealants were high. Clinical relevance: ART can safely be used in single-surface cavities in both primary and permanent teeth. ART sealants have a high caries preventive effect

    Technical design of the phase I Mu3e experiment

    Get PDF
    The Mu3e experiment aims to find or exclude the lepton flavour violating decay μeee\mu \rightarrow eee at branching fractions above 101610^{-16}. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of 210152\cdot 10^{-15}. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to 10810^{8} muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.Comment: 114 pages, 185 figures. Submitted to Nuclear Instruments and Methods A. Edited by Frank Meier Aeschbacher This version has many enhancements for better readability and more detail
    corecore