45 research outputs found

    Determining Vitamin D Status: A Comparison between Commercially Available Assays

    Get PDF
    Background: Vitamin D is not only important for bone health but can also affect the development of several non-bone diseases. The definition of vitamin D insufficiency by serum levels of 25-hydroxyvitamin D depends on the clinical outcome but might also be a consequence of analytical methods used for the definition. Although numerous 25-hydroxyvitamin D assays are available, their comparability is uncertain. We therefore aim to investigate the precision, accuracy and clinical consequences of differences in performance between three common commercially available assays. Methodology/Principal Findings: Serum 25-hydroxyvitamin D levels from 204 twins from the Swedish Twin Registry were determined with high-pressure liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLCAPCI-MS), a radioimmunoassay (RIA) and a chemiluminescent immunoassay (CLIA). High inter-assay disagreement was found. Mean 25-hydroxyvitamin D levels were highest for the HPLC-APCI-MS technique (85 nmol/L, 95% CI 81-89), intermediate for RIA (70 nmol/L, 95% CI 66-74) and lowest with CLIA (60 nmol/L, 95% CI 56-64). Using a 50-nmol/L cut-off, 8% of the subjects were insufficient using HPLC-APCI-MS, 22% with RIA and 43% by CLIA. Because of the heritable component of 25-hydroxyvitamin D status, the accuracy of each method could indirectly be assessed by comparison of within-twin pair correlations. The strongest correlation was found for HPLC-APCI-MS (r = 0.7), intermediate for RIA (r = 0.5) and lowest for CLIA (r = 0.4). Regression analyses between the methods revealed a non-uniform variance (p<0.0001) depending on level of 25-hydroxyvitamin D. Conclusions/Significance: There are substantial inter-assay differences in performance. The most valid method was HPLCAPCI-MS. Calibration between 25-hydroxyvitamin D assays is intricate

    Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS

    Get PDF
    Vitamin D is an important determinant of bone health at all ages. The plasma concentrations of 25-hydroxy vitamin D (25-OH D) and other metabolites are used as biomarkers for vitamin sufficiency and function. To allow for the simultaneous determination of five vitamin D metabolites, 25-OH D3, 25-OH D2, 24,25-(OH)2 D3, 1,25-(OH)2 D3, and 1,25-(OH)2 D2, in low volumes of human plasma, an assay using ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) was established. Plasma samples were spiked with isotope-labeled internal standards and pretreated using protein precipitation, solid-phase extraction (SPE) and a Diels–Alder derivatization step with 4-phenyl-1,2,4-triazoline-3,5-dione. The SPE recovery rates ranged from 55% to 85%, depending on the vitamin D metabolite; the total sample run time was <5 min. Mass spectrometry was conducted using positive ion electrospray ionization in the multiple reaction monitoring mode on a quadrupole–quadrupole-linear ion trap instrument after pre-column addition of methylamine to increase the ionization efficiency. The intra- and inter-day relative standard deviations were 1.6–4.1% and 3.7–6.8%, respectively. The limit of quantitation for these compounds was determined to be between 10 and 20 pg/mL. The 25-OH D results were compared with values obtained for reference materials (DEQAS). In addition, plasma samples were analyzed with two additional Diasorin antibody assays. All comparisons with conventional methods showed excellent correlations (r2 = 0.9738) for DEQAS samples, demonstrating the high degree of comparability of the new UHPLC-MS/MS technique to existing methods

    Vitamin D and HIV Progression among Tanzanian Adults Initiating Antiretroviral Therapy

    Get PDF
    Background: There is growing evidence of an association between low vitamin D and HIV disease progression; however, no prospective studies have been conducted among adults receiving antiretroviral therapy (ART) in sub-Saharan Africa. Methods Serum 25-hydroxyvitamin D (25(OH)D) levels were assessed at ART initiation for a randomly selected cohort of HIV-infected adults enrolled in a trial of multivitamins (not including vitamin D) in Tanzania during 2006–2010. Participants were prospectively followed at monthly clinic visits for a median of 20.6 months. CD4 T-cell measurements were obtained every 4 months. Proportional hazard models were utilized for mortality analyses while generalized estimating equations were used for CD4 T-cell counts. Results: Serum 25(OH)D was measured in 1103 adults 9.2% were classified as vitamin D deficient (30 ng/mL). After multivariate adjustment, vitamin D deficiency was significantly associated with increased mortality as compared to vitamin D sufficiency (HR: 2.00; 95% CI: 1.19–3.37; p = 0.009), whereas no significant association was found for vitamin D insufficiency (HR: 1.24; 95% CI: 0.87–1.78; p = 0.24). No effect modification by ART regimen or change in the associations over time was detected. Vitamin D status was not associated with change in CD4 T-cell count after ART initiation. Conclusions: Deficient vitamin D levels may lead to increased mortality in individuals receiving ART and this relationship does not appear to be due to impaired CD4 T-cell reconstitution. Randomized controlled trials are needed to determine the safety and efficacy of vitamin D supplementation for individuals receiving ART

    Cyclosporin Monitoring by Fluorescence Polarization Immunoassay of Whole Blood

    No full text

    An observational study reveals that neonatal vitamin D is primarily determined by maternal contributions: Implications of a new assay on the roles of vitamin D forms

    Get PDF
    Background Vitamin D concentrations during pregnancy are measured to diagnose states of insufficiency or deficiency. The aim of this study is to apply accurate assays of vitamin D forms [single- hydroxylated [25(OH)D2, 25(OH)D3], double-hydroxylated [1alpha,25(OH)2D2, 1alpha,25(OH)2D3], epimers [3-epi-25(OH)D2, 3-epi-25(OH)D3] in mothers (serum) and neonates (umbilical cord) to i) explore maternal and neonatal vitamin D biodynamics and ii) to identify maternal predictors of neonatal vitamin D concentrations. Methods All vitamin D forms were quantified in 60 mother- neonate paired samples by a novel liquid chromatography -mass spectrometry (LC-MS/MS) assay. Maternal characteristics [age, ultraviolet B exposure, dietary vitamin D intake, calcium, phosphorus and parathyroid hormone] were recorded. Hierarchical linear regression was used to predict neonatal 25(OH)D concentrations. Results Mothers had similar concentrations of 25(OH)D2 and 25(OH)D3 forms compared to neonates (17.9 +/- 13.2 vs. 15.9 +/- 13.6 ng/mL, p = 0.289) with a ratio of 1:3. The epimer concentrations, which contribute approximately 25% to the total vitamin D levels, were similar in mothers and neonates (4.8 +/- 7.8 vs. 4.5 +/- 4.7 ng/mL, p = 0.556). No correlation was observed in mothers between the levels of the circulating form (25OHD3) and its active form. Neonatal 25(OH)D2 was best predicted by maternal characteristics, whereas 25(OH)D3 was strongly associated to maternal vitamin D forms (R2 = 0.253 vs. 0.076 and R2 = 0.109 vs. 0.478, respectively). Maternal characteristics explained 12.2% of the neonatal 25(OH)D, maternal 25(OH)D concentrations explained 32.1%, while epimers contributed an additional 11.9%. Conclusions By applying anovel highly specific vitamin D assay, the present study is the first to quantify 3-epi-25(OH)D concentrations in mother - newborn pairs. This accurate assay highlights a considerable proportion of vitamin D exists as epimers and a lack of correlation between the circulating and active forms. These results highlight the need for accurate measurements to appraise vitamin D status. Maternal characteristics and circulating forms of vitamin D, along with their epimers explain 56% of neonate vitamin D concentrations. The roles of active and epimer forms in the maternal - neonatal vitamin D relationship warrant further investigation

    Method for simultaneous analysis of eight analogues of vitamin D using liquid chromatography tandem mass spectrometry

    Get PDF
    Background Despite considerable global investigation over several decades, the roles of vitamin D in health and disease development remains convoluted. One recognised issue is the difficulty of accurately measuring the active forms of vitamin D. Advances made include some new methods addressing the potential interference by excluding epimers and isobars. However, there is no evidence that epimers are without function. Therefore, the aim of this study was to develop and validate, for the first time, a new assay to simultaneously measure levels of 6 forms of vitamin D along with two epimers. The assay was applied to multilevel certified reference material calibrators and 25 pooled human sera samples obtained from the Vitamin D External Quality Assessment Scheme (DEQAS) to demonstrate its efficiency. Results The assay is capable of simultaneously measuring 8 vitamin D analogues over the calibration ranges and LODs (in nmol/L) of: 1alpha25(OH)2D2 [0.015-1; 0.01], 1alpha25(OH)2D3 [0.1-100; 0.01], 25OHD3 [0.5-100, 0.025], 3-epi-25OHD3 [0.1-100, 0.05], 25OHD2 [0.5-100, 0.025], 3-epi-25OHD2 [0.1-100, 0.05], vitamin D3 [0.5-100, 0.05] and vitamin D2 [0.5-100, 0.05], using stanozolol-d3 as internal standard. Certified reference material calibrators and external quality control samples (DEQAS) were analysed to meet the standards outlined by National Institute of Standards and Technology (NIST). Validation steps included recovery and both precision and accuracy under inter- and intra-day variation limit of detection, and analysis of each analyte over a linear range. All validation parameters were in line with acceptable Food and Drug Administration (FDA) guidelines and the standards of the National Institute of Standards and Technology (NIST). All eight analogues were quantified with the 25OHD levels being commensurate with DEQAS data. Conclusions This report details the application of a new LC-MS/MS based assay for the efficient analysis of eight analogues of vitamin D over a range of samples, which is a significant advance over the existing methods. Simultaneous measure of 8 vitamin D analogues does not compromise the analytical capability of the assay to quantify the commonly used biomarker (25OHD) for vitamin D status. The results demonstrate the feasibility of applying the assay in research and clinical practice that i) excludes misleading measures owing to epimers and isobars and ii) is able to quantify the excluded component to facilitate further in vivo investigation into the roles of ubiquitous epimers
    corecore