958 research outputs found
Context sensitive cardiac x-ray imaging: a machine vision approach to x-ray dose control
Modern cardiac x-ray imaging systems regulate their radiation output based on the thickness of the patient to maintain an acceptable signal at the input of the x-ray detector. This approach does not account for the context of the examination or the content of the image displayed. We have developed a machine vision algorithm that detects iodine-filled blood vessels and fits an idealized vessel model with the key parameters of contrast, diameter, and linear attenuation coefficient. The spatio-temporal distribution of the linear attenuation coefficient samples, when appropriately arranged, can be described by a simple linear relationship, despite the complexity of scene information. The algorithm was tested on static anthropomorphic chest phantom images under different radiographic factors and 60 dynamic clinical image sequences. It was found to be robust and sensitive to changes in vessel contrast resulting from variations in system parameters. The machine vision algorithm has the potential of extracting real-time context sensitive information that may be used for augmenting existing dose control strategies
Excitons in T-shaped quantum wires
We calculate energies, oscillator strengths for radiative recombination, and
two-particle wave functions for the ground state exciton and around 100 excited
states in a T-shaped quantum wire. We include the single-particle potential and
the Coulomb interaction between the electron and hole on an equal footing, and
perform exact diagonalisation of the two-particle problem within a finite basis
set. We calculate spectra for all of the experimentally studied cases of
T-shaped wires including symmetric and asymmetric GaAs/AlGaAs and
InGaAs/AlGaAs structures. We study in detail the
shape of the wave functions to gain insight into the nature of the various
states for selected symmetric and asymmetric wires in which laser emission has
been experimentally observed. We also calculate the binding energy of the
ground state exciton and the confinement energy of the 1D quantum-wire-exciton
state with respect to the 2D quantum-well exciton for a wide range of
structures, varying the well width and the Al molar fraction . We find that
the largest binding energy of any wire constructed to date is 16.5 meV. We also
notice that in asymmetric structures, the confinement energy is enhanced with
respect to the symmetric forms with comparable parameters but the binding
energy of the exciton is then lower than in the symmetric structures. For
GaAs/AlGaAs wires we obtain an upper limit for the binding energy
of around 25 meV in a 10 {\AA} wide GaAs/AlAs structure which suggests that
other materials must be explored in order to achieve room temperature
applications. There are some indications that
InGaAs/AlGaAs might be a good candidate.Comment: 20 pages, 10 figures, uses RevTeX and psfig, submitted to Physical
Review
Increased prevalence of sleep disturbances and daytime sleepiness in subjects with bronchial asthma: a population study of young adults in three European countries
To access publisher full text version of this article. Please click on the hyperlink in Additional Links fieldThe aim of this study was to investigate whether asthma is associated with decreased quality of sleep and increased daytime sleepiness. The study involved a random population of 2,202 subjects supplemented by 459 subjects with suspected asthma, aged 20-45 yrs. The subjects were from Reykjavik (Iceland), Uppsala and Göteborg (Sweden) and Antwerp (Belgium), and participated in the European Community Respiratory Health Survey. The investigation included a structured interview, methacholine challenge, skinprick tests and a questionnaire on sleep disturbances. Participants in Iceland and Sweden also estimated their sleep times and made peak expiratory flow (PEF) recordings during a period of 1 week. Asthma was defined as self-reported physician-diagnosed asthma with current asthma-related symptoms (n = 267). Difficulties inducing sleep (DIS) and early morning awakenings (EMA) were about twice as common, and daytime sleepiness 50% more common, in asthmatics compared with subjects without asthma. After adjusting for possible confounders, a positive association was found between asthma and: DIS (odds ratio (OR) = 1.8); EMA (OR = 2.0); daytime sleepiness (OR = 1.6); snoring (OR = 1.7); and self reported apnoeas (OR = 3.7). Allergic rhinitis, which was reported by 71% of subjects with asthma, was independently related to DIS (OR = 2.0) and daytime sleepiness (OR = 1.3). A significant correlation was found between the number of asthma-related symptoms and sleep disturbances (p < 0.001). Asthma is associated with decreased subjective quality of sleep and increased daytime sleepiness. Concurrent allergic rhinitis may be an important underlying cause of sleep impairment in asthmatic patients
The role of obesity, different fat compartments and sleep apnea severity in circulating leptin levels: the Icelandic Sleep Apnea Cohort study.
To access publisher's full text version of this article. Please click on the hyperlink in Additional Links field.To assess whether sleep apnea severity has an independent relationship with leptin levels in blood after adjusting for different measures of obesity and whether the relationship between obstructive sleep apnea (OSA) severity and leptin levels differs depending on obesity level.Cross-sectional study of 452 untreated OSA patients (377 males and 75 females), in the Icelandic Sleep Apnea Cohort (ISAC), age 54.3±10.6 (mean±s.d.), body mass index (BMI) 32.7±5.3 kg m(-2) and apnea-hypopnea index 40.2±16.1 events per h. A sleep study and magnetic resonance imaging of abdominal visceral and subcutaneous fat volume were performed, as well as fasting serum morning leptin levels were measured.Leptin levels were more highly correlated with BMI, total abdominal and subcutaneous fat volume than visceral fat volume per se. No relationship was found between sleep apnea severity and leptin levels, assessed within three BMI groups (BMI or =35 kg m(-2)). In a multiple linear regression model, adjusted for gender, BMI explained 38.7% of the variance in leptin levels, gender explained 21.2% but OSA severity did not have a significant role and no interaction was found between OSA severity and BMI on leptin levels. However, hypertension had a significant effect on the interaction between OSA severity and obesity (P=0.04). In post-hoc analysis for nonhypertensive OSA subjects (n=249), the association between leptin levels and OSA severity explained a minor but significant variance (3.2%) in leptin levels. This relationship was greatest for nonobese nonhypertensive subjects (significant interaction with obesity level). No relationship of OSA severity and leptin levels was found for hypertensive subjects (n=199).Obesity and gender are the dominant determinants of leptin levels. OSA severity is not related to leptin levels except to a minor degree in nonhypertensive nonobese OSA subjects.NIH/HL72067/HL94307,
Eimskip Fund of the University of Iceland,
Landspitali University Hospital Research Fun
The impact of COPD on health status: findings from the BOLD study
The aim of this study was to describe the impact of chronic obstructive pulmonary disease (COPD) on health status in the Burden of Obstructive Lung Disease (BOLD) populations. We conducted a cross-sectional, general population-based survey in 11 985 subjects from 17 countries. We measured spirometric lung function and assessed health status using the Short Form 12 questionnaire. The physical and mental health component scores were calculated. Subjects with COPD (post-bronchodilator forced expiratory volume in 1 s/forced vital capacity <0.70, n = 2269) had lower physical component scores (44±10 versus 48±10 units, p<0.0001) and mental health component scores (51±10 versus 52±10 units, p = 0.005) than subjects without COPD. The effect of reported heart disease, hypertension and diabetes on physical health component scores (-3 to -4 units) was considerably less than the effect of COPD Global Initiative for Chronic Obstructive Lung Disease grade 3 (-8 units) or 4 (-11 units). Dyspnoea was the most important determinant of a low physical and mental health component scores. In addition, lower forced expiratory volume in 1 s, chronic cough, chronic phlegm and the presence of comorbidities were all associated with a lower physical health component score. COPD is associated with poorer health status but the effect is stronger on the physical than the mental aspects of health status. Severe COPD has a greater negative impact on health status than self-reported cardiovascular disease and diabetes
Can Image Enhancement Allow Radiation Dose to Be Reduced Whilst Maintaining the Perceived Diagnostic Image Quality Required for Coronary Angiography?
Objectives: The aim of this research was to quantify the reduction in radiation dose facilitated by image processing alone for percutaneous coronary intervention (PCI) patient angiograms, without reducing the perceived image quality required to confidently make a diagnosis. Methods: Incremental amounts of image noise were added to five PCI angiograms, simulating the angiogram as having been acquired at corresponding lower dose levels (10-89% dose reduction). Sixteen observers with relevant experience scored the image quality of these angiograms in three states - with no image processing and with two different modern image processing algorithms applied. These algorithms are used on state-of-the-art and previous generation cardiac interventional X-ray systems. Ordinal regression allowing for random effects and the delta method were used to quantify the dose reduction possible by the processing algorithms, for equivalent image quality scores. Results: Observers rated the quality of the images processed with the state-of-the-art and previous generation image processing with a 24.9% and 15.6% dose reduction respectively as equivalent in quality to the unenhanced images. The dose reduction facilitated by the state-of-the-art image processing relative to previous generation processing was 10.3%. Conclusions: Results demonstrate that statistically significant dose reduction can be facilitated with no loss in perceived image quality using modern image enhancement; the most recent processing algorithm was more effective in preserving image quality at lower doses. Advances in knowledge: Image enhancement was shown to maintain perceived image quality in coronary angiography at a reduced level of radiation dose using computer software to produce synthetic images from real angiograms simulating a reduction in dose
- …