701 research outputs found

    Nature of the acceptor responsible for p-type conduction in liquid encapsulated Czochralski-grown undoped gallium antimonide

    Get PDF
    The acceptors in undoped liquid encapsulated Czochralski (LEC)-grown GaSb were investigated using temperature dependent Hall (TDH) and positron lifetime spectroscopy measurements. TDH measurements were performed on nonirradiated and electron irradiated undoped samples. The 34 meV acceptor was found to be the important one responsible for the p-type conduction in nonirradiated and the e--irradiated undoped materials annealed at temperatures up to 500°C. This acceptor was not related to any VGa-related defect detected and was most likely the GaSb antisite.published_or_final_versio

    Infusion of donor leukocytes to induce tolerance in organ allograft recipients

    Get PDF
    To further enhance chimerism, 229 primary allograft recipients have received perioperative intravenous infusion of a single dose of 3 to 6 x 108 unmodified donor bone marrow (BM) cells/kg body weight. In addition, 42 patients have been accrued in a concurrent protocol involving multiple (up to three) sequential perioperative infusions of 2 x 108 BM cells/kg/day from day 0-2 posttransplantation (PTx). Organ recipients (n = 133) for whom BM was not available were monitored as controls. The infusion of BM was safe and except for 50 (18%), all study patients have optimal graft function. Of the control patients, allografts in 30 (23%) have been lost during the course of follow-up. The cumulative risk of acute cellular rejection (ACR) was statistically lower in the study patients compared with that of controls. It is interesting that, 62% of BM-augmented heart recipients were free of ACR (Grade ≥ 3A) in the first 6 months PTx compared to controls. The incidence of obliterative bronchiolitis was also statistically lower in study lung recipients (3.8%) compared with the contemporaneously acquired controls (31%). The levels of donor cell chimerism were at least a log higher in the peripheral blood of majority of the study patients compared with that of controls. The incidence of donor-specific hyporeactivity, as determined by one-way mixed leukocyte reaction, was also higher in those BM-augmented liver, kidney, and lung recipients that could be evaluated compared to controls

    Right ventricular shape and function: cardiovascular magnetic resonance reference morphology and biventricular risk factor morphometrics in UK Biobank

    Get PDF
    Background The associations between cardiovascular disease (CVD) risk factors and the biventricular geometry of the right ventricle (RV) and left ventricle (LV) have been difficult to assess, due to subtle and complex shape changes. We sought to quantify reference RV morphology as well as biventricular variations associated with common cardiovascular risk factors. Methods A biventricular shape atlas was automatically constructed using contours and landmarks from 4329 UK Biobank cardiovascular magnetic resonance (CMR) studies. A subdivision surface geometric mesh was customized to the contours using a diffeomorphic registration algorithm, with automatic correction of slice shifts due to differences in breath-hold position. A reference sub-cohort was identified consisting of 630 participants with no CVD risk factors. Morphometric scores were computed using linear regression to quantify shape variations associated with four risk factors (high cholesterol, high blood pressure, obesity and smoking) and three disease factors (diabetes, previous myocardial infarction and angina). Results The atlas construction led to an accurate representation of 3D shapes at end-diastole and end-systole, with acceptable fitting errors between surfaces and contours (average error less than 1.5 mm). Atlas shape features had stronger associations than traditional mass and volume measures for all factors (p < 0.005 for each). High blood pressure was associated with outward displacement of the LV free walls, but inward displacement of the RV free wall and thickening of the septum. Smoking was associated with a rounder RV with inward displacement of the RV free wall and increased relative wall thickness. Conclusion Morphometric relationships between biventricular shape and cardiovascular risk factors in a large cohort show complex interactions between RV and LV morphology. These can be quantified by z-scores, which can be used to study the morphological correlates of disease

    Validation of Cardiovascular Magnetic Resonance-Derived Equation for Predicted Left Ventricular Mass Using the UK Biobank Imaging Cohort: Tool for Donor-Recipient Size Matching.

    Get PDF
    BACKGROUND: Current guidance from International Society for Heart and Lung Transplantation recommends using body weight for donor-recipient size matching for heart transplantation. However, recent studies have shown that predicted heart mass, using body weight, height, age, and sex, may represent a better method of size matching. We aim to validate a cardiovascular magnetic resonance (CMR)-derived equation for predicted left ventricular mass (LVM) in a cohort of normal individuals in the United Kingdom. METHODS: This observational study was conducted in 5065 middle-aged (44-77 years old) UK Biobank participants who underwent CMR imaging in 2014 to 2015. Individuals with cancer diagnosis in the previous 12 months or history of cardiovascular disease were excluded. Predicted LVM was calculated based on participants' sex, height, and weight recorded at the time of imaging. Correlation analyses were performed between the predicted LVM and the LVM obtained from manual contouring of CMR cine images. The analysis included 3398 participants (age 61.5±7.5 years, 47.8% males). RESULTS: Predicted LVM was considerably higher than CMR-derived LVM (mean±SD of 138.8±28.9 g versus 86.3±20.9 g). However, there was a strong correlation between the 2 measurements (Spearman correlation coefficient 0.802, P<0.0001). CONCLUSIONS: Predicted LVM calculated using a CMR-derived equation that incorporates height, weight, and sex has a strong correlation with CMR LVM in large cohort of normal individuals in the United Kingdom. Our findings suggest that predicted heart mass equations may be a valid tool for donor-recipient size matching for heart transplantation in the United Kingdom

    Light to moderate coffee consumption is associated with lower risk of death: a UK Biobank study

    Get PDF
    Aims: To study the association of daily coffee consumption with all-cause and cardiovascular (CV) mortality and major CV outcomes. In a subgroup of participants who underwent cardiovascular magnetic resonance (CMR) imaging, we evaluated the association between regular coffee intake and cardiac structure and function.Methods: UK Biobank participants without clinically manifested heart disease at the time of recruitment were included. Regular coffee intake was categorized into 3 groups: zero, light-to-moderate (0.5-3 cups/day) and high (&gt;3 cups/day). In the multivariate analysis, we adjusted for the main CV risk factors.Results: We included 468,629 individuals (56.2 ± 8.1 years, 44.2% male), 22.1% did not consume coffee on a regular basis, 58.4% had 0.5-3 cups per day and 19.5% had &gt;3 cups per day. Compared to non-coffee drinkers, light-to-moderate (0.5-3 cups per day) coffee drinking was associated with lower risk of all-cause mortality (multivariate HR = 0.88, 95%CI : 0.83-0.92; p &lt; 0.001) and CV mortality (multivariate HR = 0.83, 95%CI : 0.74-0.94; p = 0.006), and incident stroke (multivariate HR = 0.79, 95%CI : 0.63-0.99 p = 0.037) after a median follow-up of 11 years. CMR data were available in 30,650 participants. Both light-to-moderate and high coffee consuming categories were associated with dose-dependent increased left and right ventricular end-diastolic, end-systolic and stroke volumes, as well as greater left ventricular mass. Conclusion: Coffee consumption of up to 3 cups per day was associated with favorable CV outcomes. Regular coffee consumption was also associated with a likely healthy pattern of CMR metrics in keeping with the reverse of age-related cardiac alterations

    Prospective association between handgrip strength and cardiac structure and function in UK adults.

    Get PDF
    BACKGROUND: Handgrip strength, a measure of muscular fitness, is associated with cardiovascular (CV) events and CV mortality but its association with cardiac structure and function is unknown. The goal of this study was to determine if handgrip strength is associated with changes in cardiac structure and function in UK adults. METHODS AND RESULTS: Left ventricular (LV) ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), mass (M), and mass-to-volume ratio (MVR) were measured in a sample of 4,654 participants of the UK Biobank Study 6.3 ± 1 years after baseline using cardiovascular magnetic resonance (CMR). Handgrip strength was measured at baseline and at the imaging follow-up examination. We determined the association between handgrip strength at baseline as well as its change over time and each of the cardiac outcome parameters. After adjustment, higher level of handgrip strength at baseline was associated with higher LVEDV (difference per SD increase in handgrip strength: 1.3ml, 95% CI 0.1-2.4; p = 0.034), higher LVSV (1.0ml, 0.3-1.8; p = 0.006), lower LVM (-1.0g, -1.8 --0.3; p = 0.007), and lower LVMVR (-0.013g/ml, -0.018 --0.007; p<0.001). The association between handgrip strength and LVEDV and LVSV was strongest among younger individuals, while the association with LVM and LVMVR was strongest among older individuals. CONCLUSIONS: Better handgrip strength was associated with cardiac structure and function in a pattern indicative of less cardiac hypertrophy and remodeling. These characteristics are known to be associated with a lower risk of cardiovascular events

    Adverse cardiovascular magnetic resonance phenotypes are associated with greater likelihood of incident coronavirus disease 2019: findings from the UK Biobank.

    Get PDF
    BACKGROUND: Coronavirus disease 2019 (COVID-19) disproportionately affects older people. Observational studies suggest indolent cardiovascular involvement after recovery from acute COVID-19. However, these findings may reflect pre-existing cardiac phenotypes. AIMS: We tested the association of baseline cardiovascular magnetic resonance (CMR) phenotypes with incident COVID-19. METHODS: We studied UK Biobank participants with CMR imaging and COVID-19 testing. We considered left and right ventricular (LV, RV) volumes, ejection fractions, and stroke volumes, LV mass, LV strain, native T1, aortic distensibility, and arterial stiffness index. COVID-19 test results were obtained from Public Health England. Co-morbidities were ascertained from self-report and hospital episode statistics (HES). Critical care admission and death were from HES and death register records. We investigated the association of each cardiovascular measure with COVID-19 test result in multivariable logistic regression models adjusting for age, sex, ethnicity, deprivation, body mass index, smoking, diabetes, hypertension, high cholesterol, and prior myocardial infarction. RESULTS: We studied 310 participants (n = 70 positive). Median age was 63.8 [57.5, 72.1] years; 51.0% (n = 158) were male. 78.7% (n = 244) were tested in hospital, 3.5% (n = 11) required critical care admission, and 6.1% (n = 19) died. In fully adjusted models, smaller LV/RV end-diastolic volumes, smaller LV stroke volume, and poorer global longitudinal strain were associated with significantly higher odds of COVID-19 positivity. DISCUSSION: We demonstrate association of pre-existing adverse CMR phenotypes with greater odds of COVID-19 positivity independent of classical cardiovascular risk factors. CONCLUSIONS: Observational reports of cardiovascular involvement after COVID-19 may, at least partly, reflect pre-existing cardiac status rather than COVID-19 induced alterations

    Quantitative CMR population imaging on 20,000 subjects of the UK Biobank imaging study: LV/RV quantification pipeline and its evaluation

    Get PDF
    Population imaging studies generate data for developing and implementing personalised health strategies to prevent, or more effectively treat disease. Large prospective epidemiological studies acquire imaging for pre-symptomatic populations. These studies enable the early discovery of alterations due to impending disease, and enable early identification of individuals at risk. Such studies pose new challenges requiring automatic image analysis. To date, few large-scale population-level cardiac imaging studies have been conducted. One such study stands out for its sheer size, careful implementation, and availability of top quality expert annotation; the UK Biobank (UKB). The resulting massive imaging datasets (targeting ca. 100,000 subjects) has put published approaches for cardiac image quantification to the test. In this paper, we present and evaluate a cardiac magnetic resonance (CMR) image analysis pipeline that properly scales up and can provide a fully automatic analysis of the UKB CMR study. Without manual user interactions, our pipeline performs end-to-end image analytics from multi-view cine CMR images all the way to anatomical and functional bi-ventricular quantification. All this, while maintaining relevant quality controls of the CMR input images, and resulting image segmentations. To the best of our knowledge, this is the first published attempt to fully automate the extraction of global and regional reference ranges of all key functional cardiovascular indexes, from both left and right cardiac ventricles, for a population of 20,000 subjects imaged at 50 time frames per subject, for a total of one million CMR volumes. In addition, our pipeline provides 3D anatomical bi-ventricular models of the heart. These models enable the extraction of detailed information of the morphodynamics of the two ventricles for subsequent association to genetic, omics, lifestyle habits, exposure information, and other information provided in population imaging studies. We validated our proposed CMR analytics pipeline against manual expert readings on a reference cohort of 4620 subjects with contour delineations and corresponding clinical indexes. Our results show broad significant agreement between the manually obtained reference indexes, and those automatically computed via our framework. 80.67% of subjects were processed with mean contour distance of less than 1 pixel, and 17.50% with mean contour distance between 1 and 2 pixels. Finally, we compare our pipeline with a recently published approach reporting on UKB data, and based on deep learning. Our comparison shows similar performance in terms of segmentation accuracy with respect to human experts

    Improving the Generalizability of Convolutional Neural Network-Based Segmentation on CMR Images

    Get PDF
    Background: Convolutional neural network (CNN) based segmentation methods provide an efficient and automated way for clinicians to assess the structure and function of the heart in cardiac MR images. While CNNs can generally perform the segmentation tasks with high accuracy when training and test images come from the same domain (e.g., same scanner or site), their performance often degrades dramatically on images from different scanners or clinical sites. / Methods: We propose a simple yet effective way for improving the network generalization ability by carefully designing data normalization and augmentation strategies to accommodate common scenarios in multi-site, multi-scanner clinical imaging data sets. We demonstrate that a neural network trained on a single-site single-scanner dataset from the UK Biobank can be successfully applied to segmenting cardiac MR images across different sites and different scanners without substantial loss of accuracy. Specifically, the method was trained on a large set of 3,975 subjects from the UK Biobank. It was then directly tested on 600 different subjects from the UK Biobank for intra-domain testing and two other sets for cross-domain testing: the ACDC dataset (100 subjects, 1 site, 2 scanners) and the BSCMR-AS dataset (599 subjects, 6 sites, 9 scanners). / Results: The proposed method produces promising segmentation results on the UK Biobank test set which are comparable to previously reported values in the literature, while also performing well on cross-domain test sets, achieving a mean Dice metric of 0.90 for the left ventricle, 0.81 for the myocardium, and 0.82 for the right ventricle on the ACDC dataset; and 0.89 for the left ventricle, 0.83 for the myocardium on the BSCMR-AS dataset. / Conclusions: The proposed method offers a potential solution to improve CNN-based model generalizability for the cross-scanner and cross-site cardiac MR image segmentation task
    • …
    corecore