9,520 research outputs found
A Method for Calculating the Structure of (Singular) Spacetimes in the Large
A formalism and its numerical implementation is presented which allows to
calculate quantities determining the spacetime structure in the large directly.
This is achieved by conformal techniques by which future null infinity
(\Scri{}^+) and future timelike infinity () are mapped to grid points on
the numerical grid. The determination of the causal structure of singularities,
the localization of event horizons, the extraction of radiation, and the
avoidance of unphysical reflections at the outer boundary of the grid, are
demonstrated with calculations of spherically symmetric models with a scalar
field as matter and radiation model.Comment: 29 pages, AGG2
General Relativistic Scalar Field Models in the Large
For a class of scalar fields including the massless Klein-Gordon field the
general relativistic hyperboloidal initial value problems are equivalent in a
certain sense. By using this equivalence and conformal techniques it is proven
that the hyperboloidal initial value problem for those scalar fields has an
unique solution which is weakly asymptotically flat. For data sufficiently
close to data for flat spacetime there exist a smooth future null infinity and
a regular future timelike infinity.Comment: 22 pages, latex, AGG 1
Current dependence of grain boundary magnetoresistance in La_0.67Ca_0.33MnO_3 films
We prepared epitaxial ferromagnetic manganite films on bicrystal substrates
by pulsed laser ablation. Their low- and high-field magnetoresistance (MR) was
measured as a function of magnetic field, temperature and current. At low
temperatures hysteretic changes in resistivity up to 70% due to switching of
magnetic domains at the coercitive field are observed. The strongly non-ohmic
behavior of the current-voltage leads to a complete suppression of the MR
effect at high bias currents with the identical current dependence at low and
high magnetic fields. We discuss the data in view of tunneling and mesoscale
magnetic transport models and propose an explicit dependence of the spin
polarization on the applied current in the grain boundary region.Comment: 5 pages, to appear in J. Appl. Phy
A NICMOS Direct Imaging Search for Giant Planets around the Single White Dwarfs in the Hyades
We report preliminary results from our search for massive giant planets (6-12
Jupiter masses) around the known seven single white dwarfs in the Hyades
cluster at sub-arcsec separations. At an age of 625 Myr, the white dwarfs had
progenitor masses of about 3 solar masses, and massive gaseous giant planets
should have formed in the massive circumstellar disks around these ex-Herbig A0
stars, probably at orbital separations similar or slightly larger than that of
Jupiter. Such planets would have survived the post-Main-Sequence mass loss of
the parent star and would have migrated outward adiabatically to a distance of
about 25 AU. At the distance of the Hyades (45 pc) this corresponds to an
angular separation of 0.5 arcsec. J and H magnitudes of these giants are in the
range of 20.5-23.3 mag, which can be resolved with NICMOS. The achieved
sensitivities and contrast ratios agree well with simulations. Preliminary
evaluation of the NICMOS data set did not reveal any evidence for neither
planetary mass companions with masses down to about 10 Jupiter masses nor brown
dwarfs around any of the seven white dwarfs for separations larger than 0.5
arcsec.Comment: 14th European Workshop on White Dwarf
On the Effect of Constraint Enforcement on the Quality of Numerical Solutions in General Relativity
In Brodbeck et al 1999 it has been shown that the linearised time evolution
equations of general relativity can be extended to a system whose solutions
asymptotically approach solutions of the constraints. In this paper we extend
the non-linear equations in similar ways and investigate the effect of various
possibilities by numerical means. Although we were not able to make the
constraint submanifold an attractor for all solutions of the extended system,
we were able to significantly reduce the growth of the numerical violation of
the constraints. Contrary to our expectations this improvement did not imply a
numerical solution closer to the exact solution, and therefore did not improve
the quality of the numerical solution.Comment: 14 pages, 9 figures, accepted for publication in Phys. Rev.
Computer-assisted ex vivo, normothermic small bowel perfusion
Background: In the present study, a technique for computer-assisted, normothermic, oxygenated, ex vivo, recirculating small bowel perfusion was established as a tool to investigate organ pretreatment protocols and ischemia/reperfusion phenomena. A prerequisite for the desired setup was an organ chamber for ex vivo perfusion and the use of syngeneic whole blood as perfusate. Methods: The entire small bowel was harvested from Lewis rats and perfused in an organ chamber ex vivo for at least 2 h. The temperature was kept at 37 degrees C in a water bath. Three experimental groups were explored, characterized by different perfusion solutions. The basic perfusate consisted of syngeneic whole blood diluted with either NaCl, Krebs' solution or Krebs' solution and norepinephrine to a hematocrit of 30%. In addition, in each group l-glutamine was administered intraluminally. The desired perfusion pressure was 100 mm Hg which was kept constant with a computer-assisted data acquisition software, which measured an-line pressure, oxygenation, flow, temperature and pH and adjusted the pressure by changing the flow via a peristaltic pump. The viability of the preparation was tested by measuring oxygen consumption and maltose absorption, which requires intact enzymes of the mucosal brush border to break down maltose into glucose. Results: Organ perfusion in group 1 (dilution with NaCl) revealed problems such as hypersecretion into the bowel lumen, low vascular resistance and no maltose uptake. In contrast a viable organ could be demonstrated using Krebs' solution as dilution solution. The addition of norepinephrine led to an improved perfusion over the entire perfusion period. Maltose absorption was comparable to tests conducted with native small bower. Oxygen consumption was stable during the 2-hour perfusion period. Conclusions: The ex vivo perfusion system established enables small bowel perfusion for at least 2 h. The viability of the graft could be demonstrated. The perfusion time achieved is sufficient to study leukocyte/lymphocyte interaction with the endothelium of the graft vessels. In addition, a viable small bowel, after 2 h of ex vivo perfusion, facilitates testing of pretreatment protocols for the reduction of the immunogenicity of small bowel allografts. Copyright (C) 2000 S. Karger AG, Basel
On the existence of Killing vector fields
In covariant metric theories of coupled gravity-matter systems the necessary
and sufficient conditions ensuring the existence of a Killing vector field are
investigated. It is shown that the symmetries of initial data sets are
preserved by the evolution of hyperbolic systems.Comment: 9 pages, no figure, to appear in Class. Quant. Gra
Miniature mobile sensor platforms for condition monitoring of structures
In this paper, a wireless, multisensor inspection system for nondestructive evaluation (NDE) of materials is described. The sensor configuration enables two inspection modes-magnetic (flux leakage and eddy current) and noncontact ultrasound. Each is designed to function in a complementary manner, maximizing the potential for detection of both surface and internal defects. Particular emphasis is placed on the generic architecture of a novel, intelligent sensor platform, and its positioning on the structure under test. The sensor units are capable of wireless communication with a remote host computer, which controls manipulation and data interpretation. Results are presented in the form of automatic scans with different NDE sensors in a series of experiments on thin plate structures. To highlight the advantage of utilizing multiple inspection modalities, data fusion approaches are employed to combine data collected by complementary sensor systems. Fusion of data is shown to demonstrate the potential for improved inspection reliability
Recent advances in minimally invasive colorectal cancer surgery
Laparoscopy has improved surgical treatment of various diseases due to its limited surgical trauma and has developed as an interesting therapeutic alternative for the resection of colorectal cancer. Despite numerous clinical advantages (faster recovery, less pain, fewer wound and systemic complications, faster return to work) the laparoscopic approach to colorectal cancer therapy has also resulted in unusual complications, i.e. ureteral and bladder injury which are rarely observed with open laparotomy. Moreover, pneumothorax, cardiac arrhythmia, impaired venous return, venous thrombosis as well as peripheral nerve injury have been associated with the increased intraabdominal pressure as well as patient's positioning during surgery. Furthermore, undetected small bowel injury caused by the grasping or cauterizing instruments may occur with laparoscopic surgery. In contrast to procedures performed for nonmalignant conditions, the benefits of laparoscopic resection of colorectal cancer must be weighed against the potential for poorer long-term outcomes of cancer patients that still has not been completely ruled out. In laparoscopic colorectal cancer surgery, several important cancer control issues still are being evaluated, i.e. the extent of lymph node dissection, tumor implantation at port sites, adequacy of intraperitoneal staging as well as the distance between tumor site and resection margins. For the time being it can be assumed that there is no significant difference in lymph node harvest between laparoscopic and open colorectal cancer surgery if oncological principles of resection are followed. As far as the issue of port site recurrence is concerned, it appears to be less prevalent than first thought (range 0-2.5%), and the incidence apparently corresponds with wound recurrence rates observed after open procedures. Short-term (3-5 years) survival rates have been published by a number of investigators, and survival rates after laparoscopic surgery appears to compare well with data collected after conventional surgery for colorectal cancer. However, long-term results of prospective randomized trials are not available. The data published so far indicate that the oncological results of laparoscopic surgery compare well with the results of the conventional open approach. Nonetheless, the limited information available from prospective studies leads us to propose that minimally invasive surgery for colorectal cancer surgery should only be performed within prospective trials
Theoretical investigation into the possibility of very large moments in Fe16N2
We examine the mystery of the disputed high-magnetization \alpha"-Fe16N2
phase, employing the Heyd-Scuseria-Ernzerhof screened hybrid functional method,
perturbative many-body corrections through the GW approximation, and onsite
Coulomb correlations through the GGA+U method. We present a first-principles
computation of the effective on-site Coulomb interaction (Hubbard U) between
localized 3d electrons employing the constrained random-phase approximation
(cRPA), finding only somewhat stronger on-site correlations than in bcc Fe. We
find that the hybrid functional method, the GW approximation, and the GGA+U
method (using parameters computed from cRPA) yield an average spin moment of
2.9, 2.6 - 2.7, and 2.7 \mu_B per Fe, respectively.Comment: 8 pages, 3 figure
- …